Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
China Pharmacy ; (12): 2554-2556, 2015.
Artigo em Chinês | WPRIM | ID: wpr-500909

RESUMO

OBJECTIVE:To establish the method for the residues determination of 5 organic solvents in teicoplanin raw materi-al and injection. METHODS:Headspace GC was performed on the column with 6% cyanopropylphenyl-94% dimethyl polysiloxane (DB-624)as the stationary phase capillary column,the carrier gas was nitrogen,using the temperature program. The temperature of inlet was 200 ℃,detector was hydrogen flame ionization detector with the flow rate of 1 ml/min,split ratio was 40 ∶ 1 and the vol-ume was 1 ml. RESULTS:Good linearity of ethanol,acetone,ethyl acetate,tetrahydrofuran and triethylamine were obtained(r were 0.999 0-0.999 3);the average recoveries were respectively 95.6%,97.0%,103.2%,94.3%and 98.2%(RSD were 2.1%-4.9%, n=9);RSDs of precision and repeatability tests ≤2.6%;and the minimum detectable concentration were respectively 2,2,2,0.7 and 0.3 μg/ml. CONCLUSIONS:The established method is rapid,sensitive and accurate,and can be used for the residues determi-nation of organic solvents in teicoplanin raw materials and injection.

2.
China Pharmacy ; (12): 2977-2979, 2015.
Artigo em Chinês | WPRIM | ID: wpr-500792

RESUMO

OBJECTIVE:To establish the method for determining 10 residual organic solvents in norvancomycin hydrochloride raw material. METHODS:Headspace gas chromatography was performed on the column of nitro modified polyethylene terephthal-ate glycol as stationary phase capillary column;the oven temperature program started at 40 ℃ for 3 min and increased at a rate of 8 ℃/min up to 150 ℃ for 10 min;the temperature was 200 ℃ with carrier gas of high-purity nitrogen gas,the constant flow rate was 5 ml/min with split ratio of 15∶1;the headspace vial equilibrium temperature was 85 ℃ with equilibrium time of 40 min,and the volume was 1 ml. RESULTS:The concentration of n-pentane,acetone,ethanol,benzene,acrylonitrile,toluene,xylene,chlo-robenzene,styrene,divinylbenzene had good linear relationship with its peak area values(r=0.995 7-0.999 9);the RSDs of preci-sion,repeatability tests was ≤6.6%;average recovery was in the range of 94.3%-106.6%(RSD=0.5%-4.5%,n=9). CONCLU-SIONS:The method is fast,sensitive and accurate,and can be used for the determination of residual organic solvents in norvanco-mycin hydrochloride raw material.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA