Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Progress in Modern Biomedicine ; (24): 4325-4329, 2017.
Artigo em Chinês | WPRIM | ID: wpr-606851

RESUMO

Objective:To analyze the effect of tanreqing injection on the serum levels of transforming growth factor-β (TGF-β) and matrix metalloproteinases-9 (MMP-9) of patients with chronic obstructive pulmonary disease (COPD).Methods:102 patients with COPD were divided into the control group and the observation group according to random number table method,52 cases in each group.The control group was treated with routine therapy,and the observation group was treated with Tanreqing injection based on the control group.The serum TGF-β,MMP-9 levels,forced vital capacity (FVC),1 s forced expiratory volume (FEV1),partial pressure of carbon dioxide (PaCO2),oxygen partial pressure (PaO2),CD4+,CD86,CD4+/CD8+,syndrome integral,clinical efficacy and incidence of side effects were observed and compared between the two groups.Results:After treatment,the serum TGF-β,MMP-9 levels,PaCO2 and syndrome integral of observation group were significantly lower than those of the control group,the PaO2,CD4+,FVC,FEV1,CD4+/CD8+ and the clinical efficacy of observation group were obviously higher than those of the control group (P<0.05).There was no significant difference in the incidence of side effects between the two groups (P>0.05).Conclusion:Tanreqing injection could effectively reduce the serum levels of TGF-β and MMP-9,and improve the arterial blood gas,lung function and immune function in treatment of patients with COPD.

2.
Chinese Journal of Thoracic and Cardiovascular Surgery ; (12)2003.
Artigo em Chinês | WPRIM | ID: wpr-682131

RESUMO

Objective: To analyze the mid long term results of prosthetic valves replacement. Methods: 2?141 patients underwent prosthetic valve replacement from 1978 to 2001, and 1?681 patients were followed up by completion of 78.5%, cumulate of 8?021.1 patient years and averages of 4.77 patient years each. The data were analyzed by multi factor regression and T test. Results: 92 patients died after operation. The 5 year and 10 year survival rates were (92.3?2.2)% and (90.1?2.7)%, respectively. The main complications were thromboembolism, valve mechanical malfunction, peri prosthetic leak, hemolysis and SBE. The heart function (NYHA) was significantly improved after valve replacement. Conclusion: The mid long term results of prosthetic valve replacement are rather satisfactory with low mortality and morbidity. Subvalvular structure preservation and tricuspid annuloplasty contribute can greatly improved heart function. Satisfactory myocardial protection during CPB is the key of successful operation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA