Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Adicionar filtros








Intervalo de ano
1.
The Journal of Advanced Prosthodontics ; : 136-143, 2021.
Artigo em Inglês | WPRIM | ID: wpr-895776

RESUMO

Purpose@#This study aimed to evaluate the effect of repeated use of an implant handpiece under an implant placement torque (35 Ncm) and overloading torque condition (50 Ncm) on an output torque. @*Materials and Methods@#Two types of implant handpiece systems (Surgicpro/X-DSG20L [NSK, Kanuma, Japan] and SIP20/CRB46LN [SAESHIN, Daegu, South Korea]) were used. The output torque was measured using a digital torque gauge. The height and angle (x, y, and z axes) of the digital torque gauge and implant handpiece were adjusted through a jig for passive connection. The experiment was conducted under the setting torque value of 35 Ncm (implant placement torque) and 50 Ncm (overloading torque condition) and 30 times per set; a total of 5 sets were performed (N = 150).For statistical analysis, the difference between the groups was analyzed using the Mann–Whitney U test and the Friedman test was used to confirm the change in output torque (α=.05). @*Results@#NSK and SAESHIN implant handpieces showed significant differences in output torque results at the setting torques of 35 Ncm and 50 Ncm (P <.001). The type of implant handpiece and repeated use influenced the output torque (P <.001). @*Conclusion@#. There may be a difference between the setting torque and actual output torque due to repeated use, and the implant handpiece should be managed and repaired during long-term use. In addition, for successful implant results in dental clinics, the output torque of the implant handpiece system should be checked before implant placement.

2.
The Journal of Advanced Prosthodontics ; : 136-143, 2021.
Artigo em Inglês | WPRIM | ID: wpr-903480

RESUMO

Purpose@#This study aimed to evaluate the effect of repeated use of an implant handpiece under an implant placement torque (35 Ncm) and overloading torque condition (50 Ncm) on an output torque. @*Materials and Methods@#Two types of implant handpiece systems (Surgicpro/X-DSG20L [NSK, Kanuma, Japan] and SIP20/CRB46LN [SAESHIN, Daegu, South Korea]) were used. The output torque was measured using a digital torque gauge. The height and angle (x, y, and z axes) of the digital torque gauge and implant handpiece were adjusted through a jig for passive connection. The experiment was conducted under the setting torque value of 35 Ncm (implant placement torque) and 50 Ncm (overloading torque condition) and 30 times per set; a total of 5 sets were performed (N = 150).For statistical analysis, the difference between the groups was analyzed using the Mann–Whitney U test and the Friedman test was used to confirm the change in output torque (α=.05). @*Results@#NSK and SAESHIN implant handpieces showed significant differences in output torque results at the setting torques of 35 Ncm and 50 Ncm (P <.001). The type of implant handpiece and repeated use influenced the output torque (P <.001). @*Conclusion@#. There may be a difference between the setting torque and actual output torque due to repeated use, and the implant handpiece should be managed and repaired during long-term use. In addition, for successful implant results in dental clinics, the output torque of the implant handpiece system should be checked before implant placement.

3.
The Korean Journal of Orthodontics ; : 197-205, 2020.
Artigo | WPRIM | ID: wpr-835178

RESUMO

Objective@#To investigate the prevalence of malocclusion with respect to grade, sex, and year among Korean pre-adolescent and adolescent students during 2012–2017. @*Methods@#A total of 165,996 students (first grade [E1, 6–7 years of age], fourth grade [E4, 9–10 years], seventh grade [M1, 12–13 years], and tenth grade [H1, 15–16 years]) were selected by stratified sampling method and underwent the nationwide oral health examination performed by the Ministry of Education, Republic of Korea. The malocclusion assessments based on dentists’ judgments were “no malocclusion,” “needs orthodontic treatment (N-OTx),” and “under orthodontic treatment (U-OTx).” The sum of N-OTx and U-OTx cases was determined as the number of students with malocclusion. After analyzing the prevalence of malocclusion according to grade, sex, and year-by-year differences, Pearson correlation analyses and two-way analyses of variance were performed. @*Results@#The prevalence of malocclusion was 18.7%, which increased with the grades (E1 [8.3%] 0.05) without significant correlation (E1, ρ = 0.129; E4, ρ = –0.495; M1, ρ = 0.406; H1, ρ = –0.383; all p > 0.05). The prevalence of malocclusion within each grade group over the six-year period was more prominent in the female (p < 0.0001). @*Conclusions@#Further studies are necessary to modify the malocclusion assessment method to account for specific types of malocclusion in pre-adolescent and adolescent students.

4.
The Korean Journal of Orthodontics ; : 158-166, 2017.
Artigo em Inglês | WPRIM | ID: wpr-226288

RESUMO

OBJECTIVE: To investigate how bracket slot size affects the direction of maxillary anterior tooth movement when en-masse retraction is performed in sliding mechanics using an induction-heating typodont simulation system. METHODS: An induction-heating typodont simulation system was designed based on the Calorific Machine system. The typodont included metal anterior and resin posterior teeth embedded in a sticky wax arch. Three bracket slot groups (0.018, 0.020, and 0.022 inch [in]) were tested. A retraction force of 250 g was applied in the posterior-superior direction. RESULTS: In the anteroposterior direction, the cusp tip of the canine in the 0.020-in slot group moved more distally than in the 0.018-in slot group. In the vertical direction, all six anterior teeth were intruded in the 0.018-in slot group and extruded in the 0.020- and 0.022-in slot groups. The lateral incisor was significantly extruded in the 0.020- and 0.022-in slot groups. Significant differences in the crown linguoversion were found between the 0.018- and 0.020-in slot groups and 0.018- and 0.022-in slot groups for the central incisor and between the 0.018- and 0.022-in slot groups and 0.020- and 0.022-in slot groups for the canine. In the 0.018-in slot group, all anterior teeth showed crown mesial angulation. Significant differences were found between the 0.018- and 0.022-in slot groups for the lateral incisor and between the 0.018- and 0.020-in slot groups and 0.018- and 0.022-in slot groups for the canine. CONCLUSIONS: Use of 0.018-in slot brackets was effective for preventing extrusion and crown linguoversion of anterior teeth in sliding mechanics.


Assuntos
Coroas , Incisivo , Mecânica , Técnicas de Movimentação Dentária , Dente
5.
The Journal of Korean Academy of Prosthodontics ; : 120-127, 2015.
Artigo em Coreano | WPRIM | ID: wpr-87266

RESUMO

PURPOSE: The aim was to investigate the effect of implant thread designs on the stress dissipation of the implant. MATERIALS AND METHODS: The threads evaluated in this study included the V-shaped, buttress, reverse buttress, and square-shaped threads, which were of the same size (depth). Building four different implant/bone complexes each consisting of an implant with one of the 4 different threads on its cylindrical body (4.1 mm x 10 mm), a force of 100 N was applied onto the top of implant abutment at 30degrees with the implant axis. In order to simulate different osseointegration stages at the implant/bone interfaces, a nonlinear contact condition was used to simulate immature osseointegration and a bonding condition for mature osseointegration states. RESULTS: Stress distribution pattern around the implant differed depending on the osseointegration states. Stress levels as well as the differences in the stress between the analysis models (with different threads) were higher in the case of the immature osseointegration state. Both the stress levels and the differences between analysis models became lower at the completely osseointegrated state. Stress dissipation characteristics of the V-shape thread was in the middle of the four threads in both the immature and mature states of osseointegration. These results indicated that implant thread design may have biomechanical impact on the implant bed bone until the osseointegration process has been finished. CONCLUSION: The stress dissipation characteristics of V-shape thread was in the middle of the four threads in both the immature and mature states of osseointegration.


Assuntos
Vértebra Cervical Áxis , Análise de Elementos Finitos , Osseointegração
6.
The Journal of Korean Academy of Prosthodontics ; : 279-286, 2014.
Artigo em Coreano | WPRIM | ID: wpr-201574

RESUMO

PURPOSE: The aim of this study was to investigate the effect of implant thread profile on the marginal bone stresses which develop during implant insertion. MATERIALS AND METHODS: Four experimental implants were created by placing four different thread systems on the body (4.1 mm x 10 mm) of the ITI standard implant. The thread types studied in this study included the buttress, v-shape, reverse buttress, and square shape threads. In order to examine the insertion stress generation, 3D dynamic finite element analysis was performed which simulated the insertion process of implants into a 1.2 mm thick cortical bone plate (containing 3.5 mm pilot hole) using a PC-based DEFORM 3D (ver 6.1, SFTC, Columbus, OH, USA) program. RESULTS: Insertion stresses higher than human cortical bone developed around the implants. The level of insertion stresses was much different depending on the thread. Stress level was lowest near the v-shape thread, and highest near the square shaped thread. Difference in the interfacial bone stress level was more noticeable near the valley than the tip of the threads. CONCLUSION: Among the four threads, the v-shape thread was turned out to minimize the insertion stress level and thereby create better conditions for implant osseointegration.


Assuntos
Humanos , Placas Ósseas , Análise de Elementos Finitos , Implantes Experimentais , Osseointegração
7.
Korean Journal of Orthodontics ; : 6-15, 2011.
Artigo em Coreano | WPRIM | ID: wpr-652187

RESUMO

OBJECTIVE: The aim of this study was to evaluate the biomechanical aspects of peri-implant bone upon root contact of orthodontic microimplant. METHODS: Axisymmetric finite element modeling scheme was used to analyze the compressive strength of the orthodontic microimplant (Absoanchor SH1312-7, Dentos Inc., Daegu, Korea) placed into inter-radicular bone covered by 1 mm thick cortical bone, with its apical tip contacting adjacent root surface. A stepwise analysis technique was adopted to simulate the response of peri-implant bone. Areas of the bone that were subject to higher stresses than the maximum compressive strength (in case of cancellous bone) or threshold stress of 54.8MPa, which was assumed to impair the physiological remodeling of cortical bone, were removed from the FE mesh in a stepwise manner. For comparison, a control model was analyzed which simulated normal orthodontic force of 5 N at the head of the microimplant. RESULTS: Stresses in cancellous bone were high enough to cause mechanical failure across its entire thickness. Stresses in cortical bone were more likely to cause resorptive bone remodeling than mechanical failure. The overloaded zone, initially located at the lower part of cortical plate, proliferated upward in a positive feedback mode, unaffected by stress redistribution, until the whole thickness was engaged. CONCLUSIONS: Stresses induced around a microimplant by root contact may lead to a irreversible loss of microimplant stability.


Assuntos
Remodelação Óssea , Força Compressiva , Análise de Elementos Finitos , Cabeça
8.
Korean Journal of Orthodontics ; : 25-35, 2011.
Artigo em Coreano | WPRIM | ID: wpr-652184

RESUMO

OBJECTIVE: The purpose of this study was to optimize the thread pattern of orthodontic microimplants. METHODS: In search of an optimal thread for orthodontic microimplants, an objective function stability quotient (SQ) was built and solved which will help increase the stability and torsional strength of microimplants while reducing the bone damage during insertion. Selecting the AbsoAnchor SH1312-7 microimplant (Dentos Inc., Daegu, Korea) as a control, and using the thread height (h) and pitch (p) as design parameters, new thread designs with optimal combination of h and p combination were developed. Design soundness of the new threads were examined through insertion strain analyses using 3D finite element simulation, torque test, and clinical test. RESULTS: Solving the function SQ, four new models with optimized thread designs were developed (h200p6, h225p7, h250p8, and h275p8). Finite element analysis has shown that these new designs may cause less bone damage during insertion. The torsional strength of two models h200p6 and h225p7 were significantly higher than the control. On the other hand, clinical test of models h200p6 and h250p8 had similar success rates when compared to the control. CONCLUSIONS: Overall, the new thread designs exhibited better performance than the control which indicated that the optimization methodology may be a useful tool when designing orthodontic microimplant threads.


Assuntos
Análise de Elementos Finitos , Mãos , Entorses e Distensões , Torque
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA