International Journal of Radiation Research. 2017; 15 (2): 167-175
em Inglês | IMEMR | ID: emr-191374

RESUMO

Background: We used a MapCHECK software-based dimensional dose distribution comparison method capable of evaluating point-to-point geometrical dose differences in volume to determine whether doses obtained from an enhanced computed tomography [CT]-based treatment plan, which better defines the target regions and organs at risk, differs from doses obtained from plain CT and then evaluated the feasibility of treatment planning via enhanced CT


Materials and Methods: Forty-three randomly selected patients underwent plain and subsequent enhanced CT with the same settings. Treatment plans developed for the two scans were identical in terms of planning parameters [e.g., isocentre, gantry angle, segments] and monitor units [MU] used for dose calculation. Horizontal and vertical dose distribution planes across the same isocentre were selected from two types of plan; a two-dimensional dose distribution analysis was used to determine the Distance-To-Agree [DTA] pass ratios of corresponding dose distribution planes


Results: Obtained doses at the head and neck [H and N] and pelvic sites did not differ greatly between enhanced and plain CT. However, enhanced CT significantly influenced doses to the lower thoracic oesophagus. A corrected pass ratio that was achieved by non-pass points in lower isodose areas excluded from the statistical analysis had better clinical outcome


Conclusion: Radiation plans with multi-fields and multi-angles can reduce the influence of enhanced CT on torso cases and may even negate its influence on H and N cases. Enhanced CT can be directly used for planning unless the target region contains the lower oesophagus and its surrounding blood vessel whose high density requires correction

2.
Tropical Biomedicine ; : 191-198, 2017.
Artigo em Inglês | WPRIM | ID: wpr-630977

RESUMO

Previous studies showed that crude antigens from Trichinella spiralis adult worms (AW) can be recognized by mouse infection sera at 8 days post infection. The aim of this study was to identify the early diagnostic antigenic bands in soluble proteins from T. spiralis AW by Western blot using early infection sera. The affecting factors of adult recovery were firstly observed in this study, and the results showed that the maximum number of adults was collected from small intestine when the female BALB/c mice were orally infected with 4000 ML and sacrificed at 3 days post infection. The results of Western blot analysis showed that seven protein bands (31, 35.1, 39, 40.6, 41.9, 47 and 50.6 kDa) could be recognized by early infection sera as early as at 8-10 days post infection, and were strongly reacted with mouse infection sera at 11-12 days post infection. Our results suggested that the seven protein bands of T. spiralis AW soluble proteins might be the early expressed antigens during the intestinal stage of Trichinella infection and therefore have potential value for the early diagnosis of trichinellosis.