RESUMO
BACKGROUND@#The effects of acupuncture have varied in different randomized controlled trials (RCTs), and there are many factors that influence treatment effect of acupuncture in different outcomes, with conflicting results.@*OBJECTIVE@#To identify factors and their impact on the treatment effect of acupuncture in different outcomes.@*METHODS@#Acupuncture RCTs were searched from 7 databases including Medline (PubMed), Embase, Cochrane Central Register of Controlled Trials, China National Knowledge Infrastructure, Wanfang Database, VIP Database, and China Biology Medicine disc between January 1st, 2015 and December 31st, 2019. Eligible studies must compare acupuncture to no acupuncture, sham acupuncture, or waiting lists, and report at least 1 patient-important outcome. A multi-level meta-regression was conducted using a 3-level robust mixed model and univariate analyses were performed for all independent variables, even those excluded from the multivariable model due to collinearities. We used thresholds of 0.2 and 0.4 for the difference of standardized mean differences (SMDs), categorising them as small (<0.2), moderate (0.2-0.4), or large (>0.4) effects.@*RESULTS@#The pain construct analysis involved 211 effect estimates from 153 studies and 14 independent variables. High-frequency acupuncture treatment sessions produced larger effects compared to low-frequency sessions [large magnitude, the difference of adjusted SMDs 0.46, 95% confidence interval (CI) 0.07 to 0.84; P=0.02]. The non-pain symptoms construct analysis comprised 323 effect estimates from 231 studies and 15 independent variables. Penetrating acupuncture showed moderately larger effects when compared to non-penetrating acupuncture (0.30, 95% CI 0.06 to 0.53; P=0.01). The function construct analysis included 495 effect estimates from 274 studies and 14 independent variables. Penetrating acupuncture and the flexible acupuncture regimen showed moderately larger effects, compared to non-penetrating acupuncture and fixed regimen, respectively (0.40, 95% CI 0 to 0.80; P=0.05; 0.29, 95% CI 0.06 to 0.53; P=0.01).@*CONCLUSIONS@#High-frequency acupuncture sessions appear to be a more effective approach to managing painful symptoms. Penetrating acupuncture demonstrated greater effect in relieving non-painful symptoms. Both penetrating acupuncture type and flexible acupuncture regimen were linked to significant treatment effects in function outcomes. Future studies should consider the factors that are significantly associated with the effects of acupuncture in patient-important outcomes.
Assuntos
Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto , Terapia por Acupuntura/métodos , Dor , Manejo da Dor , ChinaRESUMO
OBJECTIVE@#To evaluate the report quality of Chinese and English randomized controlled trials (RCTs) of acupuncture based on the CONSORT statement and STRICTA checklist.@*METHODS@#The Chinese and English RCTs of acupuncture published from January 1, 2015 to December 31, 2019 were searched in 7 databases including PubMed. The report quality of the included RCTs was evaluated with the CONSORT 2010 statement and STRICTA checklist.@*RESULTS@#A total of 506 Chinese RCTs and 76 English RCTs were included. According to the CONSORT statement, in Chinese RCTs, the items with report rate less than 50% accounted for 78.38% of all items, and the report rate of 25 items, such as background and reason, study design, outcome index, and sample size, was less than 10%. In English RCTs, the items with report rate less than 50% accounted for 35.14% of all items, and 5 items had a report rate of less than 10%. The difference of the report rate of 15 items, such as background, reason and study design, was more than 50% between Chinese and English RCTs. The report rate of all items of STRICTA checklist was relatively high in both Chinese and English RCTs. In Chinese RCTs, the items with report rate less than 50% accounted for 29.41% of all items, which included acupuncture rationale and depth of insertion. In English RCTs, only two items had a report rate less than 50%, which were acupuncture rationale, setting and context of treatment. The report rate of five items, including needle retention time, frequency and duration of treatment sessions, details of other interventions administered to the acupuncture group, setting and context of treatment, and precise description of the control or comparator in Chinese RCTs, were higher than in English RCTs.@*CONCLUSION@#The report quality of Chinese acupuncture RCT needs to be improved urgently, and corresponding measures should be taken to further standardize the writing and reporting of acupuncture clinical research.
Assuntos
Humanos , Terapia por Acupuntura , Lista de Checagem , Ensaios Clínicos Controlados Aleatórios como Assunto/normasRESUMO
As an indicator that measures the degree of implementation of intervention measures during the implementation process, fidelity could be used for monitoring and quality evaluation of the completion degree of intervention measures, and plays an important role in improving the degree of intervention implementation and clarifying the factors that affect intervention implementation. This article aims to introduce the connotation and significance, measurement, control, and current application status of fidelity, as well as the current application status of fidelity in acupuncture-moxibustion clinical research and its inspiration for future research. Meanwhile, based on the existing evaluation tool development methods of fidelity and the characteristics of acupuncture-moxibustion clinical research, a preliminary fidelity evaluation framework is proposed. Introducing fidelity into acupuncture-moxibustion clinical research could improve the implementation quality and compliance of acupuncture-moxibustion in clinical research, increase the credibility and effectiveness of clinical research results, and promote the transformation of acupuncture-moxibustion experience into easily learnable and promotable treatment plans.
Assuntos
Moxibustão , Terapia por AcupunturaRESUMO
OBJECTIVES@#To evaluate the report quality, methodological quality and evidence quality of the systematic reviews and meta-analyses (SRs/MAs) of acupuncture for in vitro fertilization-embryo transfer (IVF-ET).@*METHODS@#The SRs/MAs of acupuncture for IVF-ET were searched electronically from databases of CNKI, Wanfang, VIP, SinoMed, PubMed, Embase, Cochrane Library, from inception of each database to September 27th, 2022. Two reviewers independently screened the literature and extracted the data. Using PRISMA statement, the AMSTAR 2 scale and the GRADE system, the report quality, methodological quality and evidence quality of the included SRs/MAs were assessed.@*RESULTS@#A total of 28 SRs/MAs were included, with PRISMA scores ranging from 8.5 points to 27 points. The problems of report quality focused on protocol and registration, retrieval, risk of bias in studies, additional analysis, limitations and funding. The methodological quality of included studies was generally low, reflecting on items 2, 3, 7, 10, 12 and 16. A total of 85 outcome indexes were included in the GRADE system for evidence grade evaluation. Most of the evidences were low or very low in quality. The reasons for the downgrade were related to study limitations, inconsistency, imprecision and publication bias.@*CONCLUSIONS@#Acupuncture therapy improves the outcomes of IVF-ET, but the methodological quality and evidence quality of related SRs/MAs are low. It is recommended to conduct more high-quality studies in the future to provide more reliable evidences.
Assuntos
Terapia por Acupuntura/métodos , Bases de Dados Factuais , Transferência Embrionária , Fertilização in vitro , Viés de Publicação , Revisões Sistemáticas como AssuntoRESUMO
OBJECTIVE@#To summarize and identify the available instruments/methods assessing the adequacy of acupuncture in randomized controlled trials (RCTs) for proposing a new improved instrument.@*METHODS@#A systematic literature search was carried out in 7 electronic databases from inception until 21st November 2022. Any study evaluating the adequacy or quality of acupuncture, specifying specific acupuncture treatment-related factors as criteria of subgroup analysis, or developing an instrument/tool to assess the adequacy or quality of acupuncture in an RCT was included. Basic information, characteristics and contents of acupuncture adequacy assessment were presented as frequencies and percentages.@*RESULTS@#Forty studies were included in this systematic review. Thirty-five studies (87.50%) were systematic reviews, none of which used formal methods to develop the assessment instruments/methods of acupuncture adequacy; of 5 methodological studies, only 1 study used a relatively formal method. Thirty-two studies (82.05%) assessed the components of acupuncture, while 7 (17.95%) assessed the overall quality of acupuncture. An independent assessment instrument/method was used to assess acupuncture adequacy in 29 studies (74.35%), whereas as one part of a methodological quality assessment scale in 10 (25.65%). Only 9 (23.00%) studies used the assessment results for subgroup analysis, sensitivity analysis or the criteria for inclusion in the meta-analysis.@*CONCLUSION@#Assessment contents for adequacy or quality of acupuncture in RCTs hadn't still reached consensus and no widely used assessment tools appeared. The methodology of available assessment instruments/scales is far from formal and rigorous. A new instrument/tool assessing adequacy of acupuncture should be developed using a formal method.
Assuntos
Terapia por Acupuntura/métodos , Ensaios Clínicos Controlados Aleatórios como AssuntoRESUMO
The clinical evidences on acupuncture and moxibustion for the treatment of frozen shoulder were sorted and summarized systematically. The relevant articles of frozen shoulder treated with acupuncture and moxibustion were searched from PubMed, EMbase, Cochrane database of systematic review (CDSR), Cochrane database of controlled trials register (CENTRAL), China national knowledge infrastructure (CNKI), Wanfang, VIP, and Chinese biomedical literature databases (SinoMed), from database inception to May 31, 2021. Using AMSTAR-2, the methodological quality of the included systematic reviews was evaluated. With evidence map, the current status of clinical evidence was summarized on acupuncture and moxibustion in treatment of frozen shoulder. A total of 266 original studies and 6 systematic reviews were included finally. At present, many randomized controlled trials are designed with small sample size and the simple acupuncture and moxibustion therapy is dominant as the intervention, e.g. warm acupuncture, acupuncture with filiform needle, acupotomy and electroacupuncture. The outcomes considered in the current trials focus on clinical effective rate, the score of shoulder pain, the score of shoulder function and the score of quality of life. Most of the studies have shown that acupuncture and moxibustion is advantageous as an adjunctive therapy for frozen shoulder, but its clinical evidence is few in terms of the recurrence rate and safety. Moreover, it needs to improve the evidence quality of the relevant studies on acupuncture and moxibustion for frozen shoulder.
Assuntos
Humanos , Terapia por Acupuntura , Bursite/terapia , Eletroacupuntura , Moxibustão , Qualidade de VidaRESUMO
To explore the influencing factors of acupuncture curative effect in literature of experts' experience. The journal literature of experts' experience was retrieved from China National Knowledge Infrastructure (CNKI) and PubMed, starting from inception to September 4, 2020, and the influencing factors of acupuncture curative effect were extracted and analyzed. A total of 499 articles were included, involving 495 articles in Chinese and 4 articles in English. The influencing factors of acupuncture curative effect mainly include five aspects: diagnostic method, acupoint selection of acupuncture, acupuncture manipulation, regulating mind of acupuncture and acupuncture time, and provide reference for acupuncture protocol design in clinical trials.
Assuntos
Acupuntura , Pontos de Acupuntura , Terapia por Acupuntura/métodos , PubMed , PublicaçõesRESUMO
Objective:To design a multimodality wheelchair in order to meet many use requirements of the lower limbs dyskinesia patients. Methods:For some shortcomings of the existing multimodality wheelchair such as heavy structure and drive redundancy, the design of multimodality wheelchair based on double parallelogram mechanism is studied, and a simple and reliable multimodality wheelchair mechanism is presented. Rotary actuation drives the double parallelogram mechanism and makes parts of the wheelchair move, and three posture transformations are realized. The coupling movement of the back and leg rest realizes the transformation of sitting and supine posture, and the coupling movement of seat and back realizes the change of sitting and standing posture. The mechanical analysis of wheelchairs based on uniform load was carried out, and the rotation moment is calculated. Results:When the driving torque changed from sitting position to supine position, it increased with the increase of rotation angle and reached a peak value. When the driving torque changed from sitting position to standing position, it gradually decreased with the increase of rotation angle. Then the dynamics simulation is carried out in Adams software, the calculated results were basically consistent with the simulation results. Conclusion:The proposed mechanism is helpful to realize the lightweight design of multimodality wheelchair, and meets the design needs of intelligent multimodality wheelchair.
RESUMO
<p><b>OBJECTIVE</b>To evaluate the clinical value of color Doppler in monitoring graft flow in patients who underwent simultaneous pancreas-kidney (SPK) transplantation.</p><p><b>METHODS</b>Totally 18 patients received color Doppler ultrasonography on day 1, 3, and 7 after SPK. Volumes and arteriovenous velocities of the kidney and pancreas grafts were recorded, and resistance index (RI) was calculated.</p><p><b>RESULTS</b>Color Doppler ultrasound clearly displayed the modality, size, and flow of the kidney and pancreas grafts. Compared with the single kidney grafts, the modality, volume, and arteriovenous velocity of kidney grafts in SPK was not significantly different. Although the volume of pancreas graft was remarkably larger than the normal control pancreas early after transplantation, no difference in artery velocity was found between pancreas graft and normal pancreas. The spectrum of the portal vein in pancreas grafts showed the typical spectrum of iliac veins.</p><p><b>CONCLUSION</b>Color Doppler ultrasound is sensitive in monitoring the graft flow of SPK recipients and can be used to identify postoperative vascular complications and evaluate tissue perfusion.</p>