Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Adicionar filtros








Intervalo de ano
1.
Chinese Journal of Blood Transfusion ; (12): 954-958, 2022.
Artigo em Chinês | WPRIM | ID: wpr-1004150

RESUMO

【Objective】 To investigate HIV-1 subtype distribution and trend among Dalian blood donors between 2011 and 2020, in order to provide information to improve blood safety and HIV prevention. 【Methods】 HIV RNA was purified from plasma samples of Dalian blood donors with confirmed HIV infection, which were collected between 2011 and 2020. The HIV pol gene was amplified and sequenced. HIV-1 subtypes were determined by phylogenetic analysis. 【Results】 HIV RNA was successfully genotyped in 174 samples from HIV-infected donors. The main subtypes among Dalian blood donors were CRF01_AE(69.5%), CRF07_BC(17.2%), B(5.2%), CRF02_AG(2.9%), C(1.1%), CRF55_01B(1.1%), CRF08_BC(0.6%), CRF59_01B(0.6%) and CRF79_0107(0.6%). There were still 2 cases (1.1%) unclassified. Significant difference was observed when comparing with the published national data. The prevalence of CRF01_AE strains decreased over the years, while CRF07_BC increased significantly. CRF02_AG carriers differed from donors infected with other HIV subtypes by being mostly females (40.0% vs. 2.4%), aged (median: 35y vs. 26y) and lower educational background(junior school degree or below). And 96.7% of local CRF01_AE cases were related to HIV strains, which were reported to circulate in Northeast China and in the MSM population. 【Conclusion】 HIV-1 among Dalian blood donors had unique molecular epidemiology and the trends of 07_BC increasing and 01_AE decreasing lagged behind the overall national data. Donor education on blood safety and consultation services to high risk group before donation still need improvement.

2.
Chinese Journal of Blood Transfusion ; (12): 950-954, 2022.
Artigo em Chinês | WPRIM | ID: wpr-1004149

RESUMO

【Objective】 To investigate the serological and molecular characteristics of HBsAg+ /HBV DNA non-reactive (NR) infections. 【Methods】 Samples tested as HBsAg+ and HBV DNA NR were confirmed by individual NAT repeat testing, viral particle concentration by PEG precipitation combined with in-house nested PCR and real-time quantitative PCR, anti-HBc testing, and HBsAg quantification. HBV sequences were compared with those from donors with chronic and occult infection as controls. 【Results】 A total of 792 195 samples were screened between January 2011 and December 2020, of which 53 (1: 14 947) were confirmed HBsAg+ /HBV DNA NR. HBV DNA was detected further in five (9.4%) samples; three S sequences and four Pre Core/Core sequences were obtained. Unique amino acid substitutions (P130T, P135Q/S, R151Q, G153S and S155F) were found in the Core protein that may affect virus packaging and replication. 【Conclusion】 Extremely low HBV DNA level was detected in plasmas of HBsAg+ /HBV DNA NR donors. Barely detectable HBV DNA might be associated with unusual mutations in the Pre Core/Core protein affecting viral replication. More sensitive HBV DNA and/or HBsAg assays may be considered to further reduce the potential HBV transfusion-transmission residual risk.

3.
Chinese Journal of Blood Transfusion ; (12): 882-885, 2021.
Artigo em Chinês | WPRIM | ID: wpr-1004436

RESUMO

【Objective】 To improve the efficiency and screening strategy by evaluating the performance of HBsAg screening before blood donation in Dalian. 【Methods】 The confirmed HBsAg positive samples were detected qualitatively and quantitatively, and retested with HBsAg rapid testing kit pre-donational used parallelly. Efficiency of HBsAg screening before donation was calculated, and compared between first-time and repeated donors. 【Results】 The pre-donation HBsAg screening was conducted for 199 553 cases, including 95 321 first-time donors (63.2%) and 55 396 repeated donors(36.8%).1 015 donors (first-time/repeated: 999/16) were reactive in HBsAg rapid testing. 113 samples (first-time/repeated: 108/5), initially negative in HBsAg rapid testing, were confirmed HBsAg positive by laboratory testing. The efficiency of pre-donation HBsAg screening for first-time donors(10.9‰) was significantly higher than that of repeated donors(0.3‰)(P130) and 92.44 (18.7->130), respectively. 【Conclusion】 The HBsAg rapid testing kit used in Dalian Blood Center could meet requirements for blood donor screening before donation, while good efficiency of HBsAg pre-donation screening could be achieved only in first-time blood donors.

4.
Chinese Journal of Blood Transfusion ; (12): 1181-1185, 2021.
Artigo em Chinês | WPRIM | ID: wpr-1003999

RESUMO

【Objective】 To confirm Hepatitis B virus (HBV) infections and identify infection status by excluding false positive in blood donors reactive to nucleic acid testing (NAT) but without serological markers (Seroneg-NAT). 【Methods】 Seroneg-NAT yields were selected among blood donors in Dalian Blood Center from November 1, 2010 to February 28, 2021, and their HBV DNA was further confirmed with TaqMan HBV DNA quantification or virions concentration by polyethylene glycol (PEG) precipitation combined with in-house nested PCR targeting the S, BCP, PreS/S and Precore/core regions of the viral genome, and follow-up test was carried out, including blood routine screening and HBsAg, anti-HBs and anti-HBc testing. HBV infection was confirmed by HBV DNA yielding and anti-HBs/anti-HBc seroconversion in follow-up testing, and HBV DNA was further sequenced if necessary. 【Results】 During the period of 10 years and 4 months, 0.03% (126/466 911) Seroneg-NAT yields were selected, of which 46.8% (59/126) were HBV DNA+ and 53.2% (67/126) were unconfirmed. Among 126 Seroneg-NAT yields, 40.5% (51/126) were involved in follow-up test, of which 28 were HBV DNA+ and 23 were unconfirmed. HBV infections were confirmed in 48% (60/126) of Seroneg-NAT yields. Of follow-up donors, 54.9% (28/51) were identified as early infection before seroconversion, 2.0% (1/51) seronegative occult HBV infection (OBI), and 37.3% (19/51) NAT false positive. There were still 5.9% (3/51) classified as the indetermination. 【Conclusion】 Nearly half Seroneg-NAT yields in Dalian blood donors were infected with HBV and more than 50% were early infections before seroconversion. The majority of HBV DNA unconfirmed without serological markers were false positives.

5.
Acta Pharmaceutica Sinica B ; (6): 476-487, 2021.
Artigo em Inglês | WPRIM | ID: wpr-881148

RESUMO

Dendritic cell-based cancer vaccines (DC vaccines) have been proved efficient and safe in immunotherapy of various cancers, including melanoma, ovarian and prostate cancer. However, the clinical responses were not always satisfied. Here we proposed a novel strategy to prepare DC vaccines. In the present study, a fusion protein SNU containing a secretin-penetratin (SecPen) peptide, NY-ESO-1 and ubiquitin was designed and expressed. To establish the DC vaccine (DC-SNU), the mouse bone marrow-derived DCs (BMDCs) were isolated, pulsed with SNU and maturated with cytokine cocktail. Then peripheral blood mononuclear cells (PBMCs) from C57BL/6 mice inoculated intraperitoneally with DC-SNU were separated and cocultured with MC38/MC38

6.
Chinese Journal of Medical Imaging ; (12): 943-947, 2016.
Artigo em Chinês | WPRIM | ID: wpr-510871

RESUMO

Purpose To compare the CTPA image quality by using contrast agent with different concentration at different injection rate so as to provide suitable contrast agent injection for patients.Materials and Methods A total of 346 patients with suspected acute pulmonary embolism who required to undergo CTPA examination were randomly assigned to high (370 mgI/ml) and low (320 mgI/ml) concentration groups,and each group was further divided into six subgroups with different velocity (3.0,3.2,3.4,3.6,3.8 and 4.0 ml/s).The CT value of the main pulmonary artery,right pulmonary upper lobe artery and right lung under leaf posterior basal segmental artery was measured.Results In the high concentration group,there were no significant differences in pulmonary artery average CT value,noise,single to noise ratio (SNR) and contrast to noise ratio (CNR) among the subgroups with different velocity (P>0.05).In the low concentration group,the difference was not statistically significant in pulmonary artery average CT value (P>0.05) among the subgroups with different velocity;however,the noise,SNR and CNR of 3.0 ml/s subgroup had significant differences compared with other subgroups (P<0.05).There was no significant difference in average CT value of pulmonary artery between the subgroups with the same velocity in the two concentration groups (P>0.05).In addition,except that the noise,SNR and CNR of 3.0 ml/s subgroup showed significant differences with other subgroups either in high concentration group or in low concentration group (P<0.05),there were no significant differences in the above-mentioned parameters among other subgroups with the same velocity in both groups (P>0.05).Conclusion Compared with high concentration contrast agent,the image obtained by using low concentration contrast agent shows no difference in pulmonary artery average CT value but with low iodine flow and iodine flow rate,which can reduce the risks of contrast media induced nephropathy (CIN) and contrast agent extravasation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA