Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Adicionar filtros








Intervalo de ano
1.
Chongqing Medicine ; (36): 1500-1502, 2017.
Artigo em Chinês | WPRIM | ID: wpr-511925

RESUMO

Objective To compare the effect and safety of arthroscopic debridement enmbined with intercondylar fossa angioplasty in the elder with knee osteoarthritis.Methods Six-eight elderly with knee osteoarthritis were selected from June 2012 to December 2014 in this hospital and they were averagely and randomly divided into group A and B.Patients in group A were given arthroscopic debridement,while in group B were given and arthroscopic debridement,intercondylar fossa angioplasty.The levels of VAS scores,Lysholm scores,WOMAC scores and joint range of motion were measured and compared between the two groups after 3 months,6 months and 12 months of operation.The adverse events of the two groups were supervised and compared as well.Results All elder in the two groups had apparently decreasing in VAS scores and WOMAC scores (P<0.05) after operation.Compared with group A,patients in group B had lower levels of VAS scores and WOMAC scores(P<0.05) at 12 months after operation.The level of Lysholm score was significantly increased in the two groups after treatment(P<0.05),while group B had a higher level at 12 months after treatment than group A (P<0.05).The joint range of motion in the two groups were improved after treatment(P<0.05).The elder patients in group B had better joint range of motion than group A at 6 and 12 months after operation (P<0.05).Early postoperative swelling in the joints was the adverse event after operation,but there was no statistically difference between two groups.Conclusion The combination of arthroscopic debridement and intercondylar fossa angioplasty is effective to release knee pain,increase the clinical efficacy and improve the knee function.

2.
Chinese Journal of Medical Education Research ; (12): 930-932,933, 2015.
Artigo em Chinês | WPRIM | ID: wpr-602477

RESUMO

To discover medical teaching method which is more funny and effective in early clinical contact education, Eye optical hospital affiliated to Wenzhou Medical University set up oph-thalmic microsurgery experience teaching course for junior medical students and set a variety of eye surgery simulation experience content, such as conjunctival suture surgery, corneal suture surgery, cataract surgery, eye surgery simulation and so on, which can effectively arouse students' professional interest in learning and promote students' thinking and exploration to their profession.

3.
Chinese Journal of Analytical Chemistry ; (12): 49-54, 2015.
Artigo em Chinês | WPRIM | ID: wpr-457804

RESUMO

Infant hair is a good medium to assess the cumulative exposure level of infant in the mother ' s body. Chlorinated persistent organic pollutants were ubiquitous and with the highest volume concentration in the human body. In this experiment, 20 infant hairs were collected from Beijing. The sample was overnight incubated in HCl, extracted with the mixture of hexane and dichloromethane, and cleaned up by a cartridge filled with alumina and acidified silica. The final eluate was concentrated, and 16 kinds of typical chlorinated persistent organic pollutants were detected with gas chromatography_high resolution mass spectrometry ( HRGC_MS). The results showed that the detection limit of the target compounds in sample was 1. 00-2. 50 μg/kg, the recovery of surrogate in all samples was more than 67 . 6%, and the range of recoveries for target compounds in spiked sample was 62. 5%-92. 3%. The positive rate is 100% for hexachlorobenzene,β_HCH and p, pˊ_DDE, 85% for γ_HCH, 50% for PCB28, and 40% for PCB52. The concentrations of Hexachlorobenzene, HCHs, DDTs and PCBs were 5. 48-8. 40 μg/kg, 3. 86-27. 1 μg/kg, 1. 16-18. 3 μg/kg and 2. 20-22. 1 μg/kg, respectively. The average concentrations were 7. 84 μg/kg for hexachlorobenzene, 6. 93 μg/kg for HCHs, 5. 53 μg/kg for DDTs, and 3. 44 μg/kg for PCBs. The method and the analysis results can be used to evaluate the accumulation level and cumulative exposure level of 16 target compounds for fetal in motherˊs body.

4.
Chinese Journal of Analytical Chemistry ; (12): 1053-1056, 2014.
Artigo em Chinês | WPRIM | ID: wpr-452352

RESUMO

A method was developed for the determination of four kinds of bisphenolic and halogenated bisphenolic compounds including bisphenol F, bisphenol A, tetrachlorobisphenol A, tetrabromobisphenol A in human urine using high performance liquid chromatography-tandem mass spectrometry. The analytes was extracted by solid phase extraction. The separation of the analytes was achieved on an Atlantis T3 column (3. 0×150 mm, 3 μm) gradient eluted with the mobile phase of acetonitrile and water at the rate of 250 μL/min, and detected by an electrospray ionization tandem mass spectrometry in the multiple-reaction-monitoring negative mode. The quantification was carried out by matrix-matched calibration curve. The average recoveries at 3 spiked levels were 86%-118%, with intra-day precision of 2 . 6%-17 . 0% and inter-day precision of 3. 2%-18. 0%. The limits of detection of four analytes (S/N=3) were 0. 01-0. 25 μg/L. The method was applied to the analysis of 200 human urines samples and the results showed that the method was simple, sensitive and reliable.

5.
Chinese Journal of Analytical Chemistry ; (12): 1281-1287, 2014.
Artigo em Chinês | WPRIM | ID: wpr-456428

RESUMO

A method of solid phase extraction coupled with ultra performance liquid chromatography-tandem mass spectrometry ( SPE-UPLC/MS/MS) was developed for the determination of 15 phthalate esters. Drinking water samples were concentrated by C18 SPE cartridge. The fifteen phthalate esters were separated on a phenyl column with gradient elution using methanol and water as mobile phases. Multiple reaction monitoring ( MRM) acquisition under positive ion mode was performed. The external matrix standard solutions were used for the quantitative determination. The linear range of Di-n-butyl phthalate was 0. 63-1000 μg/L. The other 14 phthalate esters showed good linearity in the range of 0 . 002-500 μg/L with the correlation coefficients more than 0. 9970. The limits of quantification ( LOQ) were 2. 2-632 ng/L. The spiked recoveries ranged from 81 . 3% to 109%. The relative standard deviations were less than 14%.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA