1.
Journal of Southern Medical University ; (12): 1233-1240, 2023.
Artigo em Chinês | WPRIM | ID: wpr-987040

RESUMO

OBJECTIVE@#To propose a sensitivity test method for geometric correction position deviation of cone-beam CT systems.@*METHODS@#We proposed the definition of center deviation and its derivation. We analyzed the influence of the variation of the three-dimensional spatial center of the steel ball point, the projection center and the size of the steel ball point on the deviation of geometric parameters and the reconstructed image results by calculating the geometric correction parameters based on the Noo analytical method using the FDK reconstruction algorithm for image reconstruction.@*RESULTS@#The radius of the steel ball point was within 3 mm. The deviation of the center of the calibration parameter was within the order of magnitude and negligible. A 10% Gaussian perturbation of a single pixel in the 3D spatial coordinates of the steel ball point produced a deviation of about 3 pixel sizes, while the same Gaussian perturbation of the 2D projection coordinates of the steel ball point produced a deviation of about 2 pixel sizes.@*CONCLUSION@#The geometric correction is more sensitive to the deviation generated by the three-dimensional spatial coordinates of the steel ball point with limited sensitivity to the deviation generated by the two-dimensional projection coordinates of the steel ball point. The deviation sensitivity of a small diameter steel ball point can be ignored.


Assuntos
Algoritmos , Calibragem , Tomografia Computadorizada de Feixe Cônico , Aço
2.
Journal of Biomedical Engineering ; (6): 951-959, 2021.
Artigo em Chinês | WPRIM | ID: wpr-921833

RESUMO

In order to suppress the geometrical artifacts caused by random jitter in ray source scanning, and to achieve flexible ray source scanning trajectory and meet the requirements of task-driven scanning imaging, a method of free trajectory cone-beam computed tomography (CBCT) reconstruction is proposed in this paper. This method proposed a geometric calibration method of two-dimensional plane. Based on this method, the geometric calibration phantom and the imaging object could be simultaneously imaged. Then, the geometric parameters could be obtained by online calibration method, and then combined with the geometric parameters, the alternating direction multiplier method (ADMM) was used for image iterative reconstruction. Experimental results showed that this method obtained high quality reconstruction image with high contrast and clear feature edge. The root mean square errors (RMSE) of the simulation results were rather small, and the structural similarity (SSIM) values were all above 0.99. The experimental results showed that it had lower image information entropy (IE) and higher contrast noise ratio (CNR). This method provides some practical value for CBCT to realize trajectory freedom and obtain high quality reconstructed image.


Assuntos
Algoritmos , Calibragem , Tomografia Computadorizada de Feixe Cônico , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas