Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Adicionar filtros








Intervalo de ano
1.
Chinese Journal of Digestive Endoscopy ; (12): 372-378, 2023.
Artigo em Chinês | WPRIM | ID: wpr-995393

RESUMO

Objective:To construct a real-time artificial intelligence (AI)-assisted endoscepic diagnosis system based on YOLO v3 algorithm, and to evaluate its ability of detecting focal gastric lesions in gastroscopy.Methods:A total of 5 488 white light gastroscopic images (2 733 images with gastric focal lesions and 2 755 images without gastric focal lesions) from June to November 2019 and videos of 92 cases (288 168 clear stomach frames) from May to June 2020 at the Digestive Endoscopy Center of Renmin Hospital of Wuhan University were retrospectively collected for AI System test. A total of 3 997 prospective consecutive patients undergoing gastroscopy at the Digestive Endoscopy Center of Renmin Hospital of Wuhan University from July 6, 2020 to November 27, 2020 and May 6, 2021 to August 2, 2021 were enrolled to assess the clinical applicability of AI System. When AI System recognized an abnormal lesion, it marked the lesion with a blue box as a warning. The ability to identify focal gastric lesions and the frequency and causes of false positives and false negatives of AI System were statistically analyzed.Results:In the image test set, the accuracy, the sensitivity, the specificity, the positive predictive value and the negative predictive value of AI System were 92.3% (5 064/5 488), 95.0% (2 597/2 733), 89.5% (2 467/ 2 755), 90.0% (2 597/2 885) and 94.8% (2 467/2 603), respectively. In the video test set, the accuracy, the sensitivity, the specificity, the positive predictive value and the negative predictive value of AI System were 95.4% (274 792/288 168), 95.2% (109 727/115 287), 95.5% (165 065/172 881), 93.4% (109 727/117 543) and 96.7% (165 065/170 625), respectively. In clinical application, the detection rate of local gastric lesions by AI System was 93.0% (6 830/7 344). A total of 514 focal gastric lesions were missed by AI System. The main reasons were punctate erosions (48.8%, 251/514), diminutive xanthomas (22.8%, 117/514) and diminutive polyps (21.4%, 110/514). The mean number of false positives per gastroscopy was 2 (1, 4), most of which were due to normal mucosa folds (50.2%, 5 635/11 225), bubbles and mucus (35.0%, 3 928/11 225), and liquid deposited in the fundus (9.1%, 1 021/11 225).Conclusion:The application of AI System can increase the detection rate of focal gastric lesions.

2.
Chinese Journal of Digestive Endoscopy ; (12): 293-297, 2023.
Artigo em Chinês | WPRIM | ID: wpr-995384

RESUMO

Objective:To assess the diagnostic efficacy of upper gastrointestinal endoscopic image assisted diagnosis system (ENDOANGEL-LD) based on artificial intelligence (AI) for detecting gastric lesions and neoplastic lesions under white light endoscopy.Methods:The diagnostic efficacy of ENDOANGEL-LD was tested using image testing dataset and video testing dataset, respectively. The image testing dataset included 300 images of gastric neoplastic lesions, 505 images of non-neoplastic lesions and 990 images of normal stomach of 191 patients in Renmin Hospital of Wuhan University from June 2019 to September 2019. Video testing dataset was from 83 videos (38 gastric neoplastic lesions and 45 non-neoplastic lesions) of 78 patients in Renmin Hospital of Wuhan University from November 2020 to April 2021. The accuracy, the sensitivity and the specificity of ENDOANGEL-LD for image testing dataset were calculated. The accuracy, the sensitivity and the specificity of ENDOANGEL-LD in video testing dataset for gastric neoplastic lesions were compared with those of four senior endoscopists.Results:In the image testing dataset, the accuracy, the sensitivity, the specificity of ENDOANGEL-LD for gastric lesions were 93.9% (1 685/1 795), 98.0% (789/805) and 90.5% (896/990) respectively; while the accuracy, the sensitivity and the specificity of ENDOANGEL-LD for gastric neoplastic lesions were 88.7% (714/805), 91.0% (273/300) and 87.3% (441/505) respectively. In the video testing dataset, the sensitivity [100.0% (38/38) VS 85.5% (130/152), χ2=6.220, P=0.013] of ENDOANGEL-LD was higher than that of four senior endoscopists. The accuracy [81.9% (68/83) VS 72.0% (239/332), χ2=3.408, P=0.065] and the specificity [ 66.7% (30/45) VS 60.6% (109/180), χ2=0.569, P=0.451] of ENDOANGEL-LD were comparable with those of four senior endoscopists. Conclusion:The ENDOANGEL-LD can accurately detect gastric lesions and further diagnose neoplastic lesions to help endoscopists in clinical work.

3.
Chinese Journal of Digestion ; (12): 433-438, 2022.
Artigo em Chinês | WPRIM | ID: wpr-958330

RESUMO

Objective:To compare the ability of deep convolutional neural network-crop (DCNN-C) and deep convolutional neural network-whole (DCNN-W), 2 artificial intelligence systems based on different training methods to dignose early gastric cancer (EGC) diagnosis under magnifying image-enhanced endoscopy (M-IEE).Methods:The images and video clips of EGC and non-cancerous lesions under M-IEE under narrow band imaging or blue laser imaging mode were retrospectively collected in the Endoscopy Center of Renmin Hospital of Wuhan University, for the training set and test set for DCNN-C and DCNN-W. The ability of DCNN-C and DCNN-W in EGC identity in image test set were compared. The ability of DCNN-C, DCNN-W and 3 senior endoscopists (average performance) in EGC identity in video test set were also compared. Paired Chi-squared test and Chi-squared test were used for statistical analysis. Inter-observer agreement was expressed as Cohen′s Kappa statistical coefficient (Kappa value).Results:In the image test set, the accuracy, sensitivity, specificity and positive predictive value of DCNN-C in EGC diagnosis were 94.97%(1 133/1 193), 97.12% (202/208), 94.52% (931/985), and 78.91%(202/256), respectively, which were higher than those of DCNN-W(86.84%, 1 036/1 193; 92.79%, 193/208; 85.58%, 843/985 and 57.61%, 193/335), and the differences were statistically significant ( χ2=4.82, 4.63, 61.04 and 29.69, P=0.028, =0.035, <0.001 and <0.001). In the video test set, the accuracy, specificity and positive predictive value of senior endoscopists in EGC diagnosis were 67.67%, 60.42%, and 53.37%, respectively, which were lower than those of DCNN-C (93.00%, 92.19% and 87.18%), and the differences were statistically significant ( χ2=20.83, 16.41 and 11.61, P<0.001, <0.001 and =0.001). The accuracy, specificity and positive predictive value of DCNN-C in EGC diagnosis were higher than those of DCNN-W (79.00%, 70.31% and 64.15%, respectively), and the differences were statistically significant ( χ2=7.04, 8.45 and 6.18, P=0.007, 0.003 and 0.013). There were no significant differences in accuracy, specificity and positive predictive value between senior endoscopists and DCNN-W in EGC diagnosis (all P>0.05). The sensitivity of senior endoscopists, DCNN-W and DCNN-C in EGC diagnosis were 80.56%, 94.44%, and 94.44%, respectively, and the differences were not statistically significant (all P>0.05). The results of the agreement analysis showed that the agreement between senior endoscopists and the gold standard was fair to moderate (Kappa=0.259, 0.532, 0.329), the agreement between DCNN-W and the gold standard was moderate (Kappa=0.587), and the agreement between DCNN-C and the gold standard was very high (Kappa=0.851). Conclusion:When the training set is the same, the ability of DCNN-C in EGC diagnosis is better than that of DCNN-W and senior endoscopists, and the diagnostic level of DCNN-W is equivalent to that of senior endoscopists.

4.
Chinese Journal of Digestion ; (12): 606-612, 2021.
Artigo em Chinês | WPRIM | ID: wpr-912216

RESUMO

Objective:To develop early gastric cancer (EGC) detection system of magnifying blue laser imaging (ME-BLI) model and magnifying narrow-band imaging (ME-NBI) model based on deep convolutional neural network, to compare the performance differences of the two models and to explore the effects of training methods on the accuracy.Methods:The images of benign gastric lesions and EGC under ME-BLI and ME-NBI were respectively collected. A total of five data sets and three test sets were collected. Data set 1 included 2 024 noncancerous lesions and 452 EGC images under ME-BLI. Data set 2 included 2 024 noncancerous lesions and 452 EGC images under ME-NBI. Data set 3 was the combination of data set 1 and 2 (a total of 4 048 noncancerous lesions and 904 EGC images under ME-BLI and ME-NBI). Data set 4: on the basis of data set 2, another 62 noncancerous lesions and 2 305 EGC images under ME-NBI were added (2 086 noncancerous lesions and 2 757 EGC images under ME-NBI). Data set 5: on the basis of data set 3, another 62 noncancerous lesions and 2 305 EGC images under ME-NBI were added(4 110 noncancerous lesions and 3 209 EGC images under ME-NBI and ME-BLI). Test set A included 422 noncancerous lesions and 197 EGC images under ME-BLI. Test set B included 422 noncancerous lesions and 197 EGC images under ME-NBI. Test set C was the combination of test set A and B (844 noncancerous and 394 EGC images under ME-BLI and ME-NBI). Five models were constructed according to these five data sets respectively and their performance was evaluated in the three test sets. Per-lesion video was collected and used to compare the performance of deep convolutional neural network models under ME-BLI and ME-NBI for the detection of EGC in clinical environment, and compared with four senior endoscopy doctors. The primary endpoint was the diagnostic accuracy of EGG, sensitivity and specificity. Chi-square test was used for statistical analysis.Results:The performance of model 1 was the best in test set A with the accuracy, sensitivity and specificity of 76.90% (476/619), 63.96% (126/197) and 82.94% (350/422), respectively. The performance of model 2 was the best in test set B with the accuracy, sensitivity and specificity of 86.75% (537/619), 92.89% (183/197) and 83.89% (354/422), respectively. The performance of model 3 was the best in test set B with the accuracy, sensitivity and specificity of 86.91% (538/619), 84.26% (166/197) and 88.15% (372/422), respectively. The performance of model 4 was the best in test set B with the accuracy, sensitivity and specificity of 85.46% (529/619), 95.43% (188/197) and 80.81% (341/422), respectively. The performance of model 5 was the best in test set B, with the accuracy, sensitivity and specificity of 83.52% (517/619), 96.95% (191/197) and 77.25% (326/422), respectively. In terms of image recognition of EGC, the accuracy of models 2 to 5 was higher than that of model 1, and the differences were statistically significant ( χ2=147.90, 149.67, 134.20 and 115.30, all P<0.01). The sensitivity and specificity of models 2 and 3 were higher than those of model 1, the specificity of model 2 was lower than that of model 3, and the differences were statistically significant ( χ2=131.65, 64.15, 207.60, 262.03 and 96.73, all P < 0.01). The sensitivity of models 4 and 5 was higher than those of models 1 to 3, and the specificity of models 4 and 5 was lower than those of models 1 to 3, and the differences were statistically significant ( χ2=151.16, 165.49, 71.35, 112.47, 132.62, 153.14, 176.93, 74.62, 14.09, 15.47, 6.02 and 5.80, all P<0.05). The results of video test based on lesion showed that the average accuracy of doctors 1 to 4 was 68.16%. And the accuracy of models 1 to 5 was 69.47% (66/95), 69.47% (66/95), 70.53% (67/95), 76.84% (73/95) and 80.00% (76/95), respectively. There were no significant differences in the accuracy among models 1 to 5 and between models 1 to 5 and doctors 1 to 4 (all P>0.05). Conclusions:ME-BLI EGC recognition model based on deep learning has good accuracy, but the diagnostic effecacy is sligntly worse than that of ME-NBI model. The effects of EGC recognition model of ME-NBI combined with ME-BLI is better than that of a single model. A more sensitive ME-NBI model can be obtained by increasing the number of ME-NBI images, especially the images of EGG, but the specificity is worse.

5.
Chinese Journal of Digestive Endoscopy ; (12): 783-788, 2021.
Artigo em Chinês | WPRIM | ID: wpr-912173

RESUMO

Objective:To assess the influence of an artificial intelligence (AI) -assisted diagnosis system on the performance of endoscopists in diagnosing gastric cancer by magnifying narrow banding imaging (M-NBI).Methods:M-NBI images of early gastric cancer (EGC) and non-gastric cancer from Renmin Hospital of Wuhan University from March 2017 to January 2020 and public datasets were collected, among which 4 667 images (1 950 images of EGC and 2 717 of non-gastric cancer)were included in the training set and 1 539 images (483 images of EGC and 1 056 of non-gastric cancer) composed a test set. The model was trained using deep learning technique. One hundred M-NBI videos from Beijing Cancer Hospital and Renmin Hospital of Wuhan University between 9 June 2020 and 17 November 2020 were prospectively collected as a video test set, 38 of gastric cancer and 62 of non-gastric cancer. Four endoscopists from four other hospitals participated in the study, diagnosing the video test twice, with and without AI. The influence of the system on endoscopists′ performance was assessed.Results:Without AI assistance, accuracy, sensitivity, and specificity of endoscopists′ diagnosis of gastric cancer were 81.00%±4.30%, 71.05%±9.67%, and 87.10%±10.88%, respectively. With AI assistance, accuracy, sensitivity and specificity of diagnosis were 86.50%±2.06%, 84.87%±11.07%, and 87.50%±4.47%, respectively. Diagnostic accuracy ( P=0.302) and sensitivity ( P=0.180) of endoscopists with AI assistance were improved compared with those without. Accuracy, sensitivity and specificity of AI in identifying gastric cancer in the video test set were 88.00% (88/100), 97.37% (37/38), and 82.26% (51/62), respectively. Sensitivity of AI was higher than that of the average of endoscopists ( P=0.002). Conclusion:AI-assisted diagnosis system is an effective tool to assist diagnosis of gastric cancer in M-NBI, which can improve the diagnostic ability of endoscopists. It can also remind endoscopists of high-risk areas in real time to reduce the probability of missed diagnosis.

6.
International Journal of Biomedical Engineering ; (6): 62-64,后插1, 2017.
Artigo em Chinês | WPRIM | ID: wpr-606653

RESUMO

Brain-computerinterface(BCI) is a kind of direct channel for information communication and control established between the human brain and computer or other electronic equipment.BCI is a novel information communication system which does not depend on the conventional brain information pathways.The asynchronous brain-computer interface technology is based on alpha wave control,and can automatically switch system mode between working and idle and select the larger EEG signal associated with motion imagination.In this paper,the basic knowledge of BCI and alpha wave-based asynchronous BCI technology were introduced.The key technology and application prospect of the novel alpha wave-based asynchronous BCI technology were summarized,and the status and existing problems were analyzed.

7.
Tianjin Medical Journal ; (12): 737-739, 2013.
Artigo em Chinês | WPRIM | ID: wpr-475536

RESUMO

Objective To investigate the expression and clinical significance of microRNA-224 and microRNA-378e in colorectal cancer tissues and normal mucosa adjacent to tumor lesions. Methods The gene chip technology was used to detect the different expression of miRNA in colorectal carcinoma tissues and adjacent normal tissues, which was then confirmed by real-time PCR. The relationship between the pathology and clinical data was analyzed. Results The expres-sion level of miR-224 was significantly up-regulated in tumor tissue, while miR-378e was down-regulated in tumor tissue, which was confirmed by real-time PCR. The expression of miR-224 was strongly associated with histological types, while miR-378e was strongly associated with the infiltration depth of colorectal cancer. Conclusion miR-224 is a potent tumor promoter, while miR-378e is a potent tumor suppressor. Both miR-224 and miR-378e can be used as potential colorectal cancer molecular markers.

8.
China Oncology ; (12): 703-708, 2013.
Artigo em Chinês | WPRIM | ID: wpr-440734

RESUMO

Background and purpose: MicroRNAs (miRNAs) play an important role in tumor biological behavior. miRNAs are down-regulated or up-regulated in various cancer types, triggering abnormal cell differentiation, proliferation and apoptosis. This study was designed to investigate the expression and clinical signiifcance of miR-187*in colorectal cancer (CRC), and further to investigate its roles in promoting cell apoptosis. Methods:The expressions of miR-187* in 40 CRC cases were examined by real-time quantitative reverse transcription-PCR (qRT-PCR). The relationship between miR-187*expression and clinical features of CRC was analyzed. HCT116 cells were transfected with a miR-187*mimic and the apoptosis of the transfected cells were examined by lfow cytometry (FCM). Results:The expression of miR-187*was down-regulated in CRC tissues 0.165 (0.106, 0.428) compared with those in normal tissues 0.334 (0.211, 0.712) (P<0.05), especially in mucinous carcinoma and older age CRC (P<0.05). Transfection of HCT116 cells with a miR-187*mimic up-regulated the expression of miR-187*and increased cell early apoptosis (P<0.05). Conclusion: The expression level of miR-187* was lower in CRC. miR-187* expression correlates with histological type and age. Transfection of HCT116 cells with a miR-187*mimic accelerates apoptosis of tumor cells, suggesting that miR-187*is a potent tumor suppressor.

9.
Chinese Journal of Geriatrics ; (12): 391-393, 2009.
Artigo em Chinês | WPRIM | ID: wpr-394977

RESUMO

Objective To explore the correlation of pulmonary heart disease (PHD) with erythrocyte immunity function and serum erythropoietin(EPO)level. Methods Forty-eight patients with PHD were selected as PHD group, while forty people were chosen as control group. The erythrocyte C3b receptor (E-C3bRR), erythrocyte immunity complex (RBC-ICR) and serum EPO content were detected by yeast rosette method and enzyme-linked immunosorbent assay (ELISA),and blood gas indexes were examined by blood gas analyser.Results The E-C3bRR and serum EPO content were lower, while the RBC-ICR was higher in PHD group than in control group(both P< 0. 01). Compared with control group, PCOz and HCO3-levels were higher, but blood oxygen saturation(SaO2) level was lower in the PHD group than in control group(both P<0. 01). There were no differences in pH value and PO2between two groups(both P>0. 05). The E-C3bRR was positively related to serum EPO content (r=0. 623, P<0.01), and HCO3-was positively related to pH value and PCO2(r=0. 219 ,P<0. 05;r=0. 585,P<0. 01) ,whereas PCO2was negatively related to pH value(r=-0. 529,P<0.01),and PO2was positively related to SaO2(r=0. 682,P<0.01)in PHD group. Conclusions There is a correlation between E-C3bRR and serum EPO content in PHD patients.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA