Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Chinese Journal of Urology ; (12): 524-528, 2023.
Artigo em Chinês | WPRIM | ID: wpr-994074

RESUMO

Objective:To investigate the effect of Da Vinci robot-assisted single-port plus-one laparoscopic pyeloplasty (RSPY) in children with ureteropelvic junction obstruction (UPJO).Methods:The clinical data of 13 children with UPJO diagnosed by robot-assisted single-port plus-one laparoscopic pyeloplasty in Fujian Provincial Hospital from September 2021 to August 2022 were retrospectively analyzed. The mean age of the children was 60.0 (1.3, 108.0) months. The lesions of 10 patients were on the left, and 3 were on the right. The clinical manifestations were abdominal pain in 3 cases, urinary tract infection in 2 cases, and no symptoms in 10 cases. Preoperative isotope renogram showed affected renal function (28.32±1.82)%, and bilateral renal function difference > 10% in 7 cases. Mechanical obstruction existed in 5 cases. Preoperative ultrasound showed the affected side's renal cortex thickness of (1.98 ± 0.23) cm. During the operation, a single-port multi-channel trocar was placed in the umbilicus with another single port in the epigastrium, and a robotic system was placed to explore the subperitoneal dilated renal pelvis. The renal pelvis was suspended and pulled through the abdominal wall. The visual field was exposed, and the dilated renal pelvis was incised. The dilated renal pelvis was cut, a ureteral stent was placed, and the ureteropelvic duct was anastomosed.Results:The operation of 13 cases was successfully completed, without conversion to open surgery. The operation time was 180.0(165.0, 190.2)min. The intraoperative blood loss was < 5 ml. The postoperative hospital stay was 7.0(7.0, 7.0)d, and hospitalization costs were 56.3(52.1, 56.5)thousand yuan. The ureteral stent was removed 2 months after the operation, and no obvious complications such as urinary tract infection or low back pain occurred. The median postoperative follow-up was 12 months, ranged from 6 to 18 months. Urinary color ultrasound showed that the renal cortex was (4.95±0.57) cm, which was thicker than before. Isotope renogram showed that the renal function was (38.02±1.76)%, which was higher than before. Mechanical obstruction was transformed into incomplete obstruction.Conclusions:Da Vinci robot-assisted single-port plus-one laparoscopic pyeloplasty is precise and could achieve good surgical results on the basis of the effective restoration of lesion kidney function.

2.
Journal of Medical Biomechanics ; (6): E375-E381, 2023.
Artigo em Chinês | WPRIM | ID: wpr-987961

RESUMO

Objective To propose a new multi-joint series venipuncture system, explore the mechanics and kinematics-based related control problems involved in needle insertion and needle picking during the puncture process, and verify feasibility of this system. Methods A puncture manipulator was built, and needle displacement control algorithm was proposed by combing with the puncture mechanics model. The the forward kinematics was calculated by using DH method, so as to obtain the tip coordinates. Then the inverse kinematics was calculated by using the geometric method. The forward and inverse processes were closely connected. The position error of the end coordinates before and after needle picking was compared by using the method of kinematics positive solution-inverse solution-re-positive solution. Finally, experimental verification and simulation were conducted by combining with the physical object. Results Through simulation and experiments, accuracy of the theoretical model was verified. The needle insertion algorithm could be used to achieve success with only one needle insertion, which provided theoretical basis for the control of robot arm. The position error before and after needle picking could be controlled within 1 mm from the end trajectory. The end needle tip of robot arm was almost kept fixed during the needle picking process. Therefore, this needle picking scheme was feasible and could basically verify that the needle picking action of robot arm met the accuracy and safety requirements. Conclusions The venipuncture manipulator truly simulates the needle insertion and needle picking action during the puncture process, and can safely and accurately realize the needle insertion and needle picking action with needle tip as the fixed point, indicating that it has certain clinical value.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA