Artigo em Chinês | WPRIM | ID: wpr-601070

RESUMO

Objective To analyze the comparability and correlation of reticulocyte parameters on the Beckman‐Coulter LH780 (LH780)and Sysmex XN‐1000(XN‐1000)hematology analyzers .Methods 80 blood samples were measured by the two instru‐ments ,the RBC count ,percentage of Ret(Ret% ) ,Ret value(Ret#)and immature reticulocyte fraction(IRF) were analyzed ,and the correlation of Ret% ,Ret# and IRF between two instruments were also analysed .The correlation between percentage of high laser reticulocyte(HLR% ) of LH780 and percentage of middle fluorescent reticulogyte(MFR% )+percentage of high fluorescent reticu‐locyte(HFR% ) of XN‐1000 were compared using two calculation methods of each instrument ,and the application value of HLR%were analysed .Results No significant differences were founded in RBC count ,Ret% ,and Ret# between the two instruments(P>0 .05) ,while there was statistical difference in IRF between the the two instruments (P<0 .05) .The relative deviation coincidence rate of RBC count was 97 .5% ,the correlation coefficent (r) of Ret% ,Ret# and IRF were 0 .912 ,0 .895 and 0 .666 respectively . There were statistical differences and correlations between HLR% and MFR% + HFR% when using calculation method of XN‐1000 and LH780 respectively(r were 0 .666 and 0 .767 respectively ,P<0 .05) .Conclusion The RBC count could meet the matc‐hing requirement ,and the Ret% and Ret # may be highly correlated on the two instruments .While the reference range of IRF should be established in each instrument .

2.
Artigo em Chinês | WPRIM | ID: wpr-600251

RESUMO

Objective To understand the result coincidence of 4 hematology analyzers (LH780 ,LH750 ,XN-1000 ,and XS-1000i) .Methods 20 samples of routine blood test were selected and detected by different hematology analyzers whose within-run precision and between-run precision all met the requirements of WS/T 406 standard .LH750 was chose to be the reference instru-ment ,and its detection results were standard values .The relative deviations and coincidence rates of WBC ,RBC ,Hb ,HCT , PLT ,MCV ,MCH and MCHC of the other 3 hematology analyzers were calculated .The WBC and PLT coincidence results of 82 cases of low-WBC samples ,86 cases of low-PLT samples ,and 35 cases of platelet aggregation samples were investigated .Results The coincidence rates of all items were more than 90% between LH780 and LH750 .For XN-1000/XS-1000i ,the coincidence rate was 80% in HCT ,and which were less than 80% in MCV and MCHC ,and more than 85% in other items .After readjusting the calibration factors of HCT of XN-1000 and XS-1000i ,the coincidence rates of HCT ,MCV and MCHC were all increased to more than 85% .The coincidence rates of WBC and PLT were less than 70% in low-WBC samples (WBC<1 .0 × 109/L) and low-PLT samples (PLT<30 × 109/L) .The results of WBC and PLT could not reach the relative deviation standards in 35 platelet aggrega-tion samples .Conclusion The comparative tests should be carried out among different hematology analyzers in one laboratory .

3.
Artigo em Chinês | WPRIM | ID: wpr-557108

RESUMO

0.05).) Conclusions Coxsackie virus is the most common pathogen in patients with viral meningitis in Chaoshan district, and the organization of disease prevention and scientific research and clinical medical should attach importance to it.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA