Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Adicionar filtros








Intervalo de ano
1.
Chinese Journal of Practical Nursing ; (36): 8-10, 2014.
Artigo em Chinês | WPRIM | ID: wpr-455262

RESUMO

Objective To develop the improved monitoring and evaluation system of adverse drug reaction during infusion in clinic and emergency department,and investigate the effect of this system.Methods To develop monitoring and evaluation system of adverse drug reaction,which was consistent with the medical safety (adverse) event reporting,and running it.The system consisted of organizational structure,knowledge training,event reporting and processing,data analysis,quality control and continuous improvement.We collected the observed indicators of the cases of adverse drug reaction,quality and network reporting time pass rate,which were compared with those of the conventional system.Results One year during the improved system running,the cases of adverse drug reaction in clinic and emergency department infusion was reduced,the quality of reporting and handling significantly improved,network report pass rate increased.Conclusions Improved monitoring and evaluation system of adverse drug reactions has some significance in safety management of clinic and emergency department infusion,which is worthy of promotion in clinical work applications.

2.
Chinese Journal of Practical Nursing ; (36): 10-13, 2014.
Artigo em Chinês | WPRIM | ID: wpr-450475

RESUMO

Objective To discuss the application of scenario simulation technique in emergency rescue training of hospital grave pubic health events.Methods Based on the simulate function in the scenario simulation technique,we designed the emergency drill script of hospital grave pubic health events,set the simulate scene,communication system and indicators measuring emergency rescue,drilled and trained the hospital rescue crews,compared with the rescue crews trained in routine method.40 nurses were selected before or after the application of scenario simulation technique separately.Results The qualified rate of indicators such as communication and medical rescue system that were trained by scenario simulation method was higher than the rescue crews trained in routine method.Conclusions Scenario simulation technique would improve the training effect of emergency rescue in hospital grave pubic health events.

3.
Chinese Journal of Postgraduates of Medicine ; (36): 1-3, 2011.
Artigo em Chinês | WPRIM | ID: wpr-422062

RESUMO

ObjectiveTo observe the effectiveness of collagen sponge for reducing volume of drainage after surgery for lumbar spinal stenosis. MethodsOne hundred and eighty-six patients who suffered from lumbar spinal stenosis were divided into two groups by random digits table method. The test group(96 cases) used collagen sponge to cover dura mater before placing drainage tube,the control group (90 cases) was treated without collagen sponge. The volume of drainage at 1,12,24 h after surgery were observed, the blood routine test was carried out at before and 48 h after surgery and the volume and ratio of blood transfusion after surgery was also measured and compared between the two groups. ResultsThe volume of drainage were significantly decreased in the test group compared with the control group at 1,12,24h after surgery [( 106.11 ± 20.02 ) ml vs. ( 127.02 ± 25.09) ml, (236.12 ± 34.06) ml vs. (327.31 ± 51.21 )ml, (355.16 ± 49.03 ) ml vs.( 506.36 ± 85.29 ) ml](P < 0.05 ). The volume and the ratio of blood transfusion in the test group were ( 176.27 ± 21.37) ml and 10.42%(10/96) ,which were greatly lower than those in the control group[(445.94 ±24.56) ml and 32.22% (29/90)](P <0.05). The number of RBC and the concentration of Hb were (2.96 ± 0.45 ) × 1012/L and ( 106.75 ± 7.30) g/L, differently in the test group at 48 h after surgery,which were increased significantly compared with the control group[(2.35 + 0.57) × 1012/Land (90.45 ± 5.10) g/L](P < 0.05 ). ConclusionsCollagen sponge provides rapid ,effective and durable hemostasis and decreases the leak of cerebrospinal fluid after surgery for lumbar spinal stenosis. It can be used as an effective and economic method to reduce the volume of drainage after surgery.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA