Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Chinese Journal of Medical Instrumentation ; (6): 167-169, 2002.
Artigo em Chinês | WPRIM | ID: wpr-344265

RESUMO

Focused Ultrasound Surgery (FUS) is a promising minimally invasive technique in tissue ablation. Because of the high intensity at the ultrasound focus, a precise 3D-localization system is required to determine the site of the treating target in order to increase the efficiency and security of FUS. This paper represents a three dimensional ultrasound (3D US) localization system developed and its workflow. The system is mainly composed of imaging and image processing system, movement device and its controlling circuits, and position feedback device. The system has a maximum scan range of +/- 30 degrees with a resolution of 8 levels from 0.54' to 0.36 degrees. For a spherical shape like target, in theory, the maximum diameter is 160 mm the system can treat. The system can be used to localize precisely the treatment targets with general sizes in the suitable parts of the body in FUS.


Assuntos
Humanos , Algoritmos , Processamento Eletrônico de Dados , Simulação por Computador , Desenho de Equipamento , Processamento de Imagem Assistida por Computador , Métodos , Imageamento Tridimensional , Microcomputadores , Cirurgia Assistida por Computador , Métodos , Terapia por Ultrassom , Métodos
2.
Chinese Journal of Medical Instrumentation ; (6): 410-413, 2002.
Artigo em Chinês | WPRIM | ID: wpr-344244

RESUMO

The development of a RF ablation therapeutic instrument based on improved PID algorithm is introduced here. It is based on the theory of radio frequency local destruction. By adopting the improved PID temperature control algorithm, the problem of the temperature control precision reduction due to tumor tissue characteristic changing by heating has been solved, thus ensuring homogeneous and smooth radio frequency heating to tumor foci. Experiments demonstrate that the new algorithm has strong adaptability and anti-disturbance capability, the equipment works stably and reliably, and can control therapeutic temperature precisely (+/- 2 degrees C), which indicates a good clinical application value.


Assuntos
Humanos , Algoritmos , Calorimetria , Métodos , Ablação por Cateter , Métodos , Eletrodos , Desenho de Equipamento , Hipertermia Induzida , Métodos , Armazenamento e Recuperação da Informação , Neoplasias , Terapêutica , Software , Temperatura