Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Adicionar filtros








Intervalo de ano
1.
Laboratory Medicine Online ; : 7-12, 2017.
Artigo em Coreano | WPRIM | ID: wpr-100538

RESUMO

BACKGROUND: In patients with HIV, CD4+ T cell count and viral load are the main laboratory tests performed to assess clinical management. However, they require extensive resources. In this study, we aimed to determine whether hematological parameters measured using a hematology analyzer are useful as surrogate markers of CD4+ T cell count and viral load in HIV-infected patients. METHODS: Peripheral blood samples were obtained from 14 HIV-naïve, 105 HIV-treated, and 103 uninfected individuals. Hematological parameters were measured using the ADVIA 2120i hematology analyzer (Siemens Healthcare Diagnostics, USA). RESULTS: In HIV-naïve and -treated patients, the percentage of large unstained cells (%LUCs) was 2.5±1.6% and 1.9±0.7%, respectively, compared to 1.6±0.5% in HIV-uninfected controls. The %LUCs was higher in HIV patients with low CD4⁺ T cell count below 200/μL (2.4±1.0%) or high viral load ≥200 copies/mL (2.4±0.8%) than in other infected groups. Significant differences in lymphocyte count were observed between the HIV-naïve (1.5±0.6×10⁹/L) and uninfected (2.0±0.6×10⁹/L) groups as well as between HIV patients with CD4⁺ T cells ≥500/μL (2.5±0.6×10⁹/L) and other infected groups. Neutrophil count varied between high viral load (3.0±1.4×10⁹/L) and low viral load (3.7±1.3×10⁹/L) groups. The CD4⁺ T cell count correlated with lymphocyte count (r=0.642, P<0.0001) and %LUCs (r=-0.287, P=0.002). CONCLUSIONS: %LUCs, lymphocyte count, and neutrophil count are probable surrogate markers of CD4⁺ T cells and viral load.


Assuntos
Humanos , Biomarcadores , Contagem de Células , Atenção à Saúde , Progressão da Doença , Hematologia , Infecções por HIV , HIV , Contagem de Linfócitos , Neutrófilos , Linfócitos T , Carga Viral
2.
Laboratory Medicine Online ; : 36-40, 2016.
Artigo em Coreano | WPRIM | ID: wpr-220317

RESUMO

BACKGROUND: Recently, a new automated inoculating instrument, Previ Isola(R) (bioMerieux, France) was introduced. Although there are many evaluation reports about the inoculation of urine and body fluid samples using Previ Isola(R), no evaluation has been reported for blood samples. The objectives of this study were to evaluate this instrument for the inoculation of blood samples and to compare the microbiological results with the manual loop-to-plate method. METHODS: From March 2014 to July 2014, a total of 296 non-duplicate blood samples showing positive signals on the BacT/Alert 3D system were obtained, and both manual and automated methods were used for sample inoculation. Results of the two methods were compared according to five aspects: the culture result, number of single colonies, morphology of colonies, number of re-inoculations, and time required for inoculation. RESULTS: The sensitivity and specificity of Previ Isola(R) were 98.9% and 96.6%, respectively. The positive and negative predictive values were 99.6% and 90.3%, respectively, and the total concordance rate was 98.6%. For Previ Isola(R) and the manual methods, the number of average usable single colonies per plate was 25 and 16, the number of re-inoculations was 60 and 62, and the inoculation time for 15 blood samples was 30 min and 75 min, respectively. The morphology of colonies showed no differences between the two methods. CONCLUSIONS: The automated inoculation instrument, Previ Isola(R), showed relative good concordance with manual method, with high sensitivity and high specificity for blood sample inoculation. Previ Isola(R) may be useful for inoculating specimens including blood samples.


Assuntos
Automação , Líquidos Corporais , Estudos de Avaliação como Assunto , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA