Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Adicionar filtros








Intervalo de ano
1.
Chinese Journal of Stomatology ; (12): 539-545, 2018.
Artigo em Chinês | WPRIM | ID: wpr-810098

RESUMO

Objective@#To compare the phase transformation behavior, bending property and cyclic fatigue resistance of CM-wire, R-phase and M-wire nickel-titanium endodontic files treated by 3 heat treatment techniques.@*Methods@#Hyflex CM (25 mm, 25#/0.06) made from CM wire, TF (25 mm, 25#/0.06) made from R-phase heat treatment, ProTaper Next X2 (25 mm, tip size 25#/0.06) made from M-wire, Mtwo (25 mm, 25#/0.06) and ProTaper F2 (25 mm, tip size 25#/0.08) made from conventional nickel-titanium wire were chosen. Five of each files were chosen for differential scanning calorimetric (DSC) evaluation (n=5). The specimens were prepared from adjacent portions of the shaft. The weight and length were typically (20±1) mg and 2-3 mm. Another eight of the 5 nickel-titanium files were undergone cantilever-bending test, respectively (n=8). Further ten of the 5 instruments were submitted to the cyclic fatigue test by using a simulated metal root canal (n=10). The data of Ms, Mf, As, Af, ΔH, bending load, number of cyclic fatigue (NCF), fragment length were analyzed using one-way analysis of variance at a significance level of P<0.05.@*Results@#The Af of Hyflex CM [(60.27±0.94) ℃] and ProTaper Next [(51.40±0.32) ℃] were higher than body temperature of 37 ℃. The bending load values at 3.0 mm deflection of Hyflex CM [(0.867±0.074) N], TF [(1.275±0.146) N], Mtwo [(2.281±0.426) N], ProTaper Next [(3.104±0.252) N] and ProTaper [(4.227±0.483) N] increased gradually and significantly. The NCF of Hyflex CM (582±99), TF (427±85), ProTaper Next (158±22), Mtwo (129±32) and ProTaper (65±20) decreased gradually.@*Conclusions@#The 3 heat treatment techniques exert tremendous influence on the phase transformation behavior and mechanical characteristics of the files, which demonstrate improved bending property and cyclic fatigue resistance than the conventional ones.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA