Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Adicionar filtros








Intervalo de ano
1.
Chinese Journal of Epidemiology ; (12): 503-507, 2017.
Artigo em Chinês | WPRIM | ID: wpr-737672

RESUMO

Objective To construct the growth percentile curves of weight-,length/height-,head circumference and BMI for 1 to 4 year-olds who had been breastfed in urban areas.Methods Data was from the longitudinal study on 1 025 breastfed children aged 1 to 4 years,in 8 urban areas during 2008-2012.MLwiN2.25 was selected to construct the multi-level models of weight-for-age,length for-age,head circumference-for-age and BMI-for-age.The models included many growth relevant factors including gender,age,family and social demographic characteristics,perinatal factors,parent biological characteristics,dietary patterns and diseases of childen.Based on these models,predicted values (P3,P15,P50,Ps5,P97) were estimated to fit the percentiles reference curves.Results The percentiles reference curves of weight-,length/height,head circumferenceand BMI-for-age for the 1-4 year-olds who had been breastfed in the urban areas were developed.Differences of all the indicators between boys and girls were statistically significant (P<0.001).Weight,length/height,head circumference and BMI were higher in boys than those in girls,with an average differences as 0.56-0.76 kg,0.89-1.12 cm,0.64-0.91 cm and 0.31-0.52 kg/m2.Conclusion The percentiles reference curves on growth,constructed by the longitudinal observational data and scientific method,were important in reflecting the development ofbreastfed children in urban areas.

2.
Chinese Journal of Epidemiology ; (12): 503-507, 2017.
Artigo em Chinês | WPRIM | ID: wpr-736204

RESUMO

Objective To construct the growth percentile curves of weight-,length/height-,head circumference and BMI for 1 to 4 year-olds who had been breastfed in urban areas.Methods Data was from the longitudinal study on 1 025 breastfed children aged 1 to 4 years,in 8 urban areas during 2008-2012.MLwiN2.25 was selected to construct the multi-level models of weight-for-age,length for-age,head circumference-for-age and BMI-for-age.The models included many growth relevant factors including gender,age,family and social demographic characteristics,perinatal factors,parent biological characteristics,dietary patterns and diseases of childen.Based on these models,predicted values (P3,P15,P50,Ps5,P97) were estimated to fit the percentiles reference curves.Results The percentiles reference curves of weight-,length/height,head circumferenceand BMI-for-age for the 1-4 year-olds who had been breastfed in the urban areas were developed.Differences of all the indicators between boys and girls were statistically significant (P<0.001).Weight,length/height,head circumference and BMI were higher in boys than those in girls,with an average differences as 0.56-0.76 kg,0.89-1.12 cm,0.64-0.91 cm and 0.31-0.52 kg/m2.Conclusion The percentiles reference curves on growth,constructed by the longitudinal observational data and scientific method,were important in reflecting the development ofbreastfed children in urban areas.

3.
Chinese Journal of General Practitioners ; (6): 803-804, 2017.
Artigo em Chinês | WPRIM | ID: wpr-666320
4.
Chinese Journal of Radiology ; (12): 800-804, 2014.
Artigo em Chinês | WPRIM | ID: wpr-469633

RESUMO

Objective To compare the iodine intake,image quality and radiation dose of dual-source CT coronary artery angiography between the low concentration isotonic contrast agent with iterative reconstruction technique of sinogram affirmed iterative rEconstruction (SAFIRE) and common concentration contrast agent with filtered back projection (FBP).Methods One hundred patients [58 men,42 women; age:(62± 11)y] were enrolled in this study.Fifty consecutive patients (Group A) were scanned with FBP and common concentration contrast agent and another 50 consecutive patients (Group B) were scanned with low concentration isotonic contrast agent and iterative reconstruction technique.The image quality were assessed by two experienced radiologists with a double blinded fashion in a five score scale.The attenuation of coronary artery,scan time,imaging noise,signal-to-noise ratio (SNR),contrast-to-noise ratio (CNR),radiation dose and iodine intake between these two groups were compared using two sample t test.The observer agreement for image quality was calculated using Kappa statistics.Results All examinations were completed successfully.There was no statistical difference (P>0.05) between two groups in clinical characteristics and scan parameters.There was no statistical difference for the mean subjective image quality of group A (4.4±0.7) and group B (4.3±0.8) (t=0.924,P>0.05).The Kappa value between two radiologists was 0.887 (P<0.01)on image quality.The mean attenuation of coronary artery segments was higher than 300 HU,especially in group A (386.1±51.5) HU,which was slightly higher than the group B (384.1±77.1) HU,but there was no statistical difference (t=0.157,P>0.05).The SNR and CNR in two groups did not have significant differences (P>0.05).The total iodine and iodine injection rates were 21.0 g,17.5 g/s in Group A and 16.2 g,13.5 g/s in Group B,respectively.The iodine intake was decreased by 22.9% in Group B.The effective radiation dose in Group B (1.09±0.19) mSv was significantly (t=20.260,P<0.01) lower than that in Group A (2.85±0.59) mSv,with the radiation dose reduced by 61.8%.Conclusion Low concentration isotonic contrast agent and iterative reconstruction technique can significantly reduce the radiation dose and iodine intake in CT coronary artery angiography and achieve the same image quality using common concentration contrast agent with FBP.

5.
Chinese Journal of Radiological Medicine and Protection ; (12): 664-667, 2013.
Artigo em Chinês | WPRIM | ID: wpr-439251

RESUMO

Objective To explore the application of CARE kV technique in the adult chest CT and the value of reducing radiation dose.Methods Sixty-nine patients were divided into two groups by random number generators:group A(39 cases) and group B(30 cases).Group A was examined by using CARE kV technique and group B was examined at routine 120 kV.CT dose index(CTDIvol),dose length product (DLP) and effective dose (E) were compared between the two groups,and analyzed the correlation between tube voltage selection and patient body mass index (BMI) of group A was analyzed.Results The average CTDIvol [(11.00 ± 3.89) mGy],DLP[(294.05 ± 91.17) mGy·cm] and E[(4.12 ± 1.28) mSv] of group A were lower than those of group B (16.64 ± 1.20) mGy,[(475.99 ± 41.16) mGy · cm],[(6.66 ±0.58) mSv].With statistically significant difference (t =-7.653,-10.151,-10.150,P < 0.05).Compared with routine 120 kV technique (group B),the CARE kV technique (group A) could reduce the total radiation dose about 38.14%.Compared obese patients(BMI≥28 kg/m2) with non-obese patients in group A and B,the mean E of non-obese patients was lower than that of obese patients in group A,which reduced the total E about 31.74% (t =4.322,P <0.05),while E in group B was no significant different between non-obese patients and obese patients.Conclusions In adult chest CT,CARE kV technique can select optimum scanning voltage automatically according to the patients with different BMI and anatomical regions,which can reduce the overall radiation dose while maintaining image quality.

6.
Chinese Journal of Radiological Medicine and Protection ; (12): 326-328, 2012.
Artigo em Chinês | WPRIM | ID: wpr-427083

RESUMO

Objective To study the image quality and radiation dose in dual-source CT cerebral angiography with prospective ECG-triggered sequence mode (step-and-shoot,SAS).Methods A total of forty-three patients with clinically suspected cerebral vascular disease underwent cerebral CT angiography with prospective ECG-triggering (step-and-shoot,SAS).Data acquisition was at 60% R-R interval of the ECG presentation mode.The post-processing included maximum intensity projection (MIP),multiplanar reformation (MPR) and volume rendering (VR).The CTA image quality,radiation dose and rates of excellent images were evaluated.Results The CTA image quality score was 4.72 ± 0.50 and 97.7% (42/43) patients had excellent CTA images.The average effective dose of SAS-CTA was (0.22 ± 0.01 )mSv,which was lower by 76.31% than that of DE-CTA.Conclusions Prospective ECG-triggering sequence could be used in cerebral angiography with a significant reduction in radiation dose and diagnostic image quality.

7.
Chinese Journal of Radiology ; (12): 481-485, 2011.
Artigo em Chinês | WPRIM | ID: wpr-415507

RESUMO

Objective To compare the quality and radiation doses of coronary artery angiography under the natural heart rate condition between Flash spiral heart mode and prospective electrocardiogramtriggering sequence mode using dual-source,in order to choose personalized low doses of coronary artery scanning mode.Methods Sixty patients who underwent coronary angiography(CTA)on a 128-slice,dualsource CT scanner were divided into 2 group i.e,group A(27cases)and group B(33 cases).Flash spiral heart scan mode was employed for group A.Inclusion criteria included:heart rate75 bpm),date acquisition was set at 30%-50%of the R-R interval. (3)At the arrhythmias,premature beat,fibrillation atrial,date acquisition was set at 20%-90%of the R-R interval.In both gronps,patients with a BMI≥25.0kg/m2 were examined with a tube voltage of 120 kV.while the other patients with a BMI<25.0 kg/m2 were examined with a tube voltage of 100 kV.The BMl was(24.6±1.0)kg/m2 in group A,while that was (24.6±0.9)kg/m2 in group B.In both groups,all images were transferred to the workstation for further processing and analysis.The imaging quality of coronary artery segments and the radiation dose were compared with t test.Results A total of 336 coronary artery segments were evaluated in group A and 412 segments were evaluated in group B.The imaging quality of coronary artery segments were scored.Excellent or good was achieved in 98.2%(330 of 336)artery segments in group A,and that was 98.1%(404 of 412)in group B.There was no statistical difference in imaging quality between the two groups(t=0.513,P=0.608).The average effective dose was(0.74±0.29)mSv in group A,whereas that was(3.67±1.37)mSv in group B.There was a significant difference between the two groups(t=-10.858,P=0.000).Conclusions The personalized low doses coronary artery scanning mode can substantially reduce radiation damage while preserving good imaging quality.

8.
Chinese Journal of Medical Imaging Technology ; (12): 301-303, 2010.
Artigo em Chinês | WPRIM | ID: wpr-473352

RESUMO

Objective To observe the CT features of ovary Brenner tumor. Methods CT manifestations of 5 patients with ovary Brenner tumor confirmed with pathology and clinical follow-up were retrospectively analyzed, and the masses were described for location, size, configuration, enhancement pattern, presence of calcification and metastatic spread. Results There were 7 tumors in 5 patients, 3 patients had unilateral tumors and 2 had bilateral Brenner tumors (left side 3 and right side 4), with tumor size ranging from 1.52 to 16.25 cm (mean 7.36 cm). Five masses in 4 patients were benign, 2 (bilateral tumors in 1 patient) were malignant. All tumors had well-defined margin. One patient with bilateral benign tumors had large pleural effusion and seroperitoneum. Five tumors in 4 patients (5/7, 71.43%) were solid and had calcification, 2 tumors in 1 patients (2/7, 28.57%) were mainly cystic, with septa in the tumors. The solid part of all tumors were inhomogeneous and had mild enhancement. Conclusion CT findings of ovary Brenner tumor have some characteristics. Combining with clinical manifestations, CT is helpful for the diagnosis of ovary Brenner tumor.

9.
Chinese Journal of New Drugs and Clinical Remedies ; (12): 537-541, 2006.
Artigo em Chinês | WPRIM | ID: wpr-408504

RESUMO

AIM: A new HPLC-MS method was developed to determine finasteride in human plasma. METHODS: Two formulations of finasteride tablets were given to 20 healthy male volunteers according to a randomized 2-way cross-over design. The samples were extracted by ethyl acetate under basic conditions, then were separated by C18 column and determined by mass detector. RESULTS: The calibration curve of finasteride was linear and intra-day and inter-day RSD were less than 10 %. The pharmacokinetics parameters of the two formulations (4.5 ± 0.5) h for t1/2; (3.0 ± 0.7) and (2.8 ± 0.9) h for tmax, respectively. The results indicated that there was no significant difference on cmax, A UC0-24, t1/2 or tmax values between the two formulations. CONCLUTION: The relative bioavailability of tablets I with respect to tablets Ⅱ is (99.3 ± 9.2) % by the A UC0-24 measurement, and bioe quivalence is observed between the two tablets.

10.
Chinese Mental Health Journal ; (12)2002.
Artigo em Chinês | WPRIM | ID: wpr-684014

RESUMO

Objective:to collect and summary mental disturbance caused by severe craniocerebral injury Method:to compare 150 cases of mental disturbance caused by severe craniocerebral injury with those (20 cases) with similar injury but without mental disturbance Result:1) The rate of those with mental disturbance in patients with severe craniocerebral injuries was 20 8% The rate of that in all patients of head injury was 5 2% 2) 107 of our sample (71 3%, 107/150) had sub-arachnoid hemorrhage 27 had fracture at the base of skull 3) Compared with those without mental disturbance, the occurrence of mental symptoms closely related to severity of injury 4) Delirium was the early symptom, while memory deficiency and affective disorder were common on the later stages Conclusion:Patients with brain contusion with subarachnoid hemorrhage are more likely having mental disturbance

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA