Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Adicionar filtros








Intervalo de ano
1.
Korean Journal of Medicine ; : 590-592, 2008.
Artigo em Coreano | WPRIM | ID: wpr-49559

RESUMO

No abstract available.


Assuntos
Eosinofilia , Eosinófilos , Abscesso Hepático , Necrose
2.
Journal of the Korean Society of Magnetic Resonance in Medicine ; : 33-38, 2007.
Artigo em Inglês | WPRIM | ID: wpr-49832

RESUMO

PURPOSE: To investigate the applicability of the new three-dimensional overlapped reconstruction MR angiography (3-D ORMRA) technique in patients with hemifacial spasm and to compare the new 3-D reconstruction images with conventional MRA source images. MATERIALS AND METHODS: The study group comprised 27 patients with surgically proven hemifacial spasm. In all patients, conventional MRA source images and 3-D fast imaging employing steady-state acquisition (FIESTA) images were obtained prospectively. After 3-D MR angiographic images were obtained, the 3-D MRA and FIESTA images were overlapped at the workstation by using GE A/W 4.2 add/sub software. We analyzed the relationship between the offending vessels and root exit zone of the facial nerve using both 3-D ORMRA images and conventional MRA source images. RESULTS: In 25 of 27 patients, the offending vessel at the REZ of the facial nerve could be correctly identified on conventional MRA source images. In all patients, the presumed offending vessels depicted by the overlapped 3-D reconstruction MRA image corresponded well with the intraoperative findings. The 3-D reconstruction image showed more clear visualization of the spatial relationship between the offending vessels and the root exit zone of the facial nerve. CONCLUSION: The overlapped 3-D reconstruction MR angiography technique is very useful and informative in patients with hemifacial spasm, as compared with conventional MRA angiography technique.


Assuntos
Humanos , Angiografia , Nervo Facial , Espasmo Hemifacial , Estudos Prospectivos
3.
Journal of the Korean Society of Magnetic Resonance in Medicine ; : 79-85, 2004.
Artigo em Inglês | WPRIM | ID: wpr-21141

RESUMO

PURPOSE: To evaluate the usefulness and reproducibility of 1H MRS in different 1.5 T MR machines with different coils to compare the SNR, scan time and the spectral patterns in different brain regions in normal volunteers. MATERIALS AND METHODS: Localized 1H MR spectroscopy (1H MRS) was performed in a total of 10 normal volunteers (age; 20-45 years) with spectral parameters adjusted by the autoprescan routine (PROBE package). In all volunteers, MRS was performed in a three times using conventional MRS (Signa Horizon) with 1 channel coil and upgraded MRS (Echospeed plus with EXCITE) with both 1 channel and 8 channel coil. Using these three different machines and coils, SNRs of the spectra in both phantom and volunteers and (pre)scan time of MRS were compared. Two regions of the human brain (basal ganglia and deep white matter) were examined and relative metabolite ratios (NAA/Cr, Cho/Cr, and mI/Cr ratios) were measured in all volunteers. For all spectra, a STEAM localization sequence with three-pulse CHESS H2O suppression was used, with the following acquisition parameters: TR=3.0/2.0 sec, TE=30 msec, TM=13.7 msec, SW=2500 Hz, SI=2048 pts, AVG=64/128, and NEX=2/8 (Signa/Echospeed). RESULTS: The SNR was about over 30% higher in Echospeed machine and time for prescan and scan was almost same in different machines and coils. Reliable spectra were obtained on both MRS systems and there were no significant differences in spectral patterns and relative metabolite ratios in two brain regions (p>0.05). CONCLUSION: Both conventional and new MRI systems are highly reliable and reproducible for 1H MR spectroscopic examinations in human brains and there are no significant differences in applications for 1H MRS between two different MRI systems.


Assuntos
Humanos , Encéfalo , Gânglios , Voluntários Saudáveis , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Análise Espectral , Vapor , Voluntários
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA