Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Chinese Journal of Medical Imaging Technology ; (12): 550-553, 2020.
Artigo em Chinês | WPRIM | ID: wpr-861055

RESUMO

Objective: To explore the value of high frequency probe combined with end scan convex array probe transperineal ultrasonography for diagnosis of anal fistula. Methods: Data of 87 patients with anal fistula who underwent surgical treatment were retrospectively analyzed. All patients were examined with ultrasonography using 5-12 MHz linear array probe combining with palpation and visual examination for detection of external mouth and fistula before operation, also perineum ultrasound using 3-10 MHz end scan convex array probe for detection of internal mouth and typing and location of anal fistula. The consistency between results of ultrasound and surgical operation was analyzed. Results: Among 87 patients, 73 cases were diagnosed as simple anal fistula and 14 as complex anal fistula, with a total of 93 internal mouths, 101 fistula canals and 94 internal mouths were detected with surgical operation. Ultrasound correctly diagnosed anal fistula in 66 patients, missed anal fistula in 15 cases and misdiagnosed 6 cases, the coincidence rate of ultrasound and operation was 75.86% (66/87), the Kappa value was 0.344 (P<0.001).The accuracy of ultrasonography in diagnosing internal mouth, fistula canal and external mouth of anal fistula was 80.65% (75/93), 83.17% (84/101) and 87.23% (82/94), respectively, the Kappa value of consistency with operation results was 0.298, 0.407 and 0.626, respectively (all P<0.001). Conclusion: High frequency probe combined with end scan convex array probe transperineal ultrasonography is helpful to diagnosis of anal fistula.

2.
Chinese Journal of General Practitioners ; (6): 673-674, 2011.
Artigo em Chinês | WPRIM | ID: wpr-421149

RESUMO

One hundred and sixteen patients with lower limb fracture were screened by Doppler ultrasound for deep vein thrombosis(DVT) of bilateral lower extremities within the first 72 h, d7 and d21 after fracture. Results showed that DVT was detected in 31 (26. 7% ) out of 116 cases within 72 h; at d7 and d21 DVT was detected in 3 and 1 patient respectively with a cumulated DVT rate of 30. 2% in 3 weeks.Serial Doppler ultrasonography is of value in screening for DVT of the lower extremities in patients with lower limb fracture at early stage.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA