Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Adicionar filtros








Intervalo de ano
1.
Journal of Jilin University(Medicine Edition) ; (6)2006.
Artigo em Chinês | WPRIM | ID: wpr-594865

RESUMO

Objective To observe the effect of fluvastatin(Flu) on differentiation and induction of human promyelocytic leukemia HL-60 cells and provide the theoretical foundation for treatment of human promyelocytic leukemia.Methods The cultured HL-60 cells were treated with 20 ?mol?L-1 Flu,the morphological changes of the cell differentiation were examined.The NBT reduction capability was detected in HL-60 cells treated with Flu for 72 h.After HL-60 cells were treated with 20 ?mol?L-1 Flu for 5 d,they were stained with non-specific esterase and the percentage of differentiation cells was analyzed.Results The HL-60 cells treated with Flu showed smaller cell body,reducing proportion of nucleus to cytoplasm,the nucleus tortuosity,fold or sublobe.There were specific granules and vacuoles in cytoplasm,displaying that some cells had differentiated to relative mature cells.As compared with control group,the NBT reduction capability in HL-60 cells treated with Flu for 72 h was significantly higher than that in control cells(P

2.
Chinese Medical Equipment Journal ; (6)2004.
Artigo em Chinês | WPRIM | ID: wpr-595529

RESUMO

Objective To evaluate the veracity and consistency of the results obtained from three automated hematology an-alyzers. Methods The reproducibility tests were used to assess the precision,the verification tests were exerted to evaluate the accuracy and consistency of test parameters(WBC,RBC,Hb,Hct and Plt) of the three hematology analyzers. According to the 1/2 standard of American Clinical Laboratory Improvement Amendment (CLIA,88),the relative bias of the reference analyzer and other assessed analyzers were determined. Results The results obtained from the three analyzers showed ex-cellent precision and stability,the coefficients of variation (CV) were all less than 5%; compared with the results of LH750,the results of Gens 5diff and ACT-5diff showed excellent correlation,all coefficients of correlation(?) exceeded 0.975. The results of both RBC and Hct obtained from Gens 5diff and ACT-5diff exceeded allowable error; the results of WBC,Hb and Plt were in the allowable error range. Conclusion In the condition of the excellent precision and stability,system errors existed in the analyzer can be found by verification on time. Through being adjusted and calibrated,the hematology ana-lyzers can meet the requirements and these results are consistent.

3.
Chinese Medical Equipment Journal ; (6)1993.
Artigo em Chinês | WPRIM | ID: wpr-594996

RESUMO

Objective To evaluate accuracy and consistency of the coagulation convention that involves PT, INR, FIB, APTT on two coagulation analysators(ACL-9000 and ACL-200, Beckman-Coulter Corporation, US). Methods The repeatability test was used to assess the precision, the accuracy and consistency of the coagulation convention on two coagulation analysators were evaluated by comparison and analysis. Results The repeatability of related test results based on ACL-9000 coagulation analysator was better that CV value less than 5%, but the repeatability of abnormal specimens FIB based on ACL-200 was poor that CV value of 6.6%. Through comparing ACL-9000 analyzer, the test results of ACL- 200 coagulation analysator has good correlation with it, correlation coefficient ?﹥0.975. Conclusion In the condition of the excellent precision and stability, we can also find system errors existed in the analyzer on time by verificating. Through being adjusted and calibrated, the examination department can deliver the results of accuracy consistency.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA