Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Adicionar filtros








Intervalo de ano
1.
Korean Journal of Ophthalmology ; : 37-43, 2021.
Artigo em Inglês | WPRIM | ID: wpr-875238

RESUMO

Purpose@#We sought to evaluate the safety and effectiveness of patient-specific ocular prostheses produced by three-dimensional (3D) printing and the sublimation technique. A comparison with prostheses produced using manual manufacturing methods was then performed. @*Methods@#To confirm the biological and physiochemical safety, cytotoxicity, systemic acute toxicity, intradermal reaction, and skin sensitization tests were conducted according to the International Organization for Standardization guidelines. The compressive strength of the prostheses was also tested. Further, a case series of three patients who wore the 3D printed prostheses for more than eight hours daily for 4 weeks was executed. Self-assessments by these individuals using a questionnaire and safety evaluations focusing on the occurrence of conjunctival inflammation or allergic reactions according to the Cornea and Contact Lens Research Unit criteria by slit-lamp examination and similarity assessment were completed. @*Results@#The 3D printed ocular prostheses met the necessary qualifications per the biological and physiochemical safety tests, showing the absence of cytotoxicity, acute systemic toxicity, intradermal reactivity, and skin-sensitizing potency. Also, there was no difference in strength test results between previous ocular prostheses and the 3D printed ones. Self-assessment by the patients yielded satisfactory results, with no significant difference in the level of satisfaction reported for the 3D printed and previous handmade ocular prostheses. The 3D printed prosthesis did not trigger any side effects in the conjunctival sac and showed similar objective findings with respect to the color of the iris, sclera, and vessel patterns. @*Conclusions@#Our study confirms the biologic and physiochemical safety of 3D-printed ocular prostheses created using computer-aided design technology and a sublimation technique. The patients’ questionnaires and the judgment of the ophthalmologists/ocularists showed that the 3D printed ocular prosthesis was acceptable in function and appearance through a case series report.

2.
Korean Journal of Urology ; : 153-155, 1992.
Artigo em Coreano | WPRIM | ID: wpr-207594

RESUMO

A 48-year-old man presented with gross hematuria, hypertension and right flank pain. Angiography revealed unusual giant renal artery aneurysm associated with arteriovenous fistula. After nephrectomy, symptoms and signs were subsided. Herein we report this case with brief review of the literatures.


Assuntos
Humanos , Pessoa de Meia-Idade , Aneurisma , Angiografia , Fístula Arteriovenosa , Dor no Flanco , Hematúria , Hipertensão , Rim , Nefrectomia , Artéria Renal
3.
Korean Journal of Urology ; : 93-98, 1979.
Artigo em Coreano | WPRIM | ID: wpr-115553

RESUMO

One case of right duplicated ureter associated with single ectopic ureteral orifice to the vaginal vestibule in a 14-year old girl was presented. In a case, while normal self-voiding, urinary leakage has been complained since infant without other urinary symptoms and she was treated with right ureteronecystostomy in Paquin's method.


Assuntos
Adolescente , Feminino , Humanos , Lactente , Ureter
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA