Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Adicionar filtros








Intervalo de ano
1.
China Pharmacy ; (12): 1348-1354, 2022.
Artigo em Chinês | WPRIM | ID: wpr-924360

RESUMO

OBJECTIVE To systematic ally stu dy the chemic al components of ethanol extract from Sanzi san ,and to provide reference for clarifying the pharmacodynamic material basis of the formulation. METHODS HPLC-Q-Exactive-MS technology was adopted. The determination was performed on Shim-pack GIST-HP C 18 column with mobile phase consisted of acetonitrile- 0.1% formic acid aqueous solution for gradient elution at the flow rate of 1 mL/min. The column temperature was 40 ℃,and sample size was 10 μL. Mass spectrometry conditions included the electrospray spray ion source was used for detection in positive and negative ion detection modes. Full MS/dd-MS 2 detection mode was adopted ,the resolution of Full MS was 70 000 and the resolution of dd-MS2 was 17 500. The scanning range was m/z 110-1 200. The ion peaks were identified by comparing with the information of control substances ,literature references and self-built database. RESULTS A total of 64 components were identified in the ethanol extract of Mongolian medicine Sanzi san , including 9 flavonoids,13 iridoids,14 organic acids ,18 tannins,3 triterpenes,3 amino acids and 4 fatty acids. CONCLUSIONS The ethanol extract of Mongolian medicine Sanzi san mainly include iridoids ,tannins and flavonoids ,which might be the pharmacodynamic material basis of Sanzi san.

2.
China Pharmacy ; (12): 1988-1994, 2021.
Artigo em Chinês | WPRIM | ID: wpr-886583

RESUMO

OBJECTIVE:To optim ize ethanol extraction technology of Mongolian medicine Naru- 3. METHODS :The L 9(34) orthogonal design was used to optimize ethanol extraction technology of Mongolian medicine Naru- 3 with solid-liquid ratio ,ethanol volume fraction and extraction time as factors ,using comprehensive scores for the contents of benzoylaconitine ,benzoylneoaconitine, benzoylhypoaconitine,aconitine,neoaconitine,hypoaconitine,piperine and gallic acid as indexes. RESULTS :The optimal ethanol extraction technology was that solid-liquid ratio of 1∶10(g/mL),ethanol volume fraction of 75%,extracting for 1.5 h. After 3 times of validation tests ,average contents of above 8 components in ethanol extract from Naru- 3 were 1.69,1.48,14.69,0.28, 0.05,0.08,26.01,17.33 mg/g(RSDs were 0-4.96%,n=3),respectively. Average comprehensive score was 19.03(RSD=1.42%, n=3). CONCLUSIONS :The optimal ethanol extraction technology of Mongolian medicine Naru- 3 is stable and feasible.

3.
Journal of Biomedical Engineering ; (6): 473-482, 2021.
Artigo em Chinês | WPRIM | ID: wpr-888203

RESUMO

The brain-computer interface (BCI) systems used in practical applications require as few electroencephalogram (EEG) acquisition channels as possible. However, when it is reduced to one channel, it is difficult to remove the electrooculogram (EOG) artifacts. Therefore, this paper proposed an EOG artifact removal algorithm based on wavelet transform and ensemble empirical mode decomposition. Firstly, the single channel EEG signal is subjected to wavelet transform, and the wavelet components which involve EOG artifact are decomposed by ensemble empirical mode decomposition. Then the predefined autocorrelation coefficient threshold is used to automatically select and remove the intrinsic modal functions which mainly composed of EOG components. And finally the 'clean' EEG signal is reconstructed. The comparative experiments on the simulation data and the real data show that the algorithm proposed in this paper solves the problem of automatic removal of EOG artifacts in single-channel EEG signals. It can effectively remove the EOG artifacts when causes less EEG distortion and has less algorithm complexity at the same time. It helps to promote the BCI technology out of the laboratory and toward commercial application.


Assuntos
Algoritmos , Artefatos , Simulação por Computador , Eletroencefalografia , Processamento de Sinais Assistido por Computador , Análise de Ondaletas
4.
Journal of Biomedical Engineering ; (6): 606-612, 2018.
Artigo em Chinês | WPRIM | ID: wpr-687588

RESUMO

Error related negativity (ERN) is generated in frontal and central cortical regions when individuals perceive errors. Because ERN has low signal-to-noise ratio and large individual difference, it is difficult for single trial ERN recognition. In current study, the optimized electroencephalograph (EEG) channels were selected based on the brain topography of ERN activity and ERN offline recognition rate, and the optimized EEG time segments were selected based on the ERN offline recognition rate, then the low frequency time domain and high frequency time-frequency domain features were analyzed based on wavelet transform, after which the ERN single detection algorithm was proposed based on the above procedures. Finally, we achieved average recognition rate of 72.0% ± 9.6% in 10 subjects by using the sample points feature in 0~3.9 Hz and the power and variance features in 3.9~15.6 Hz from the EEG segments of 200~600 ms on the selected 6 channels. Our work has the potential to help the error command real-time correction technique in the application of online brain-computer interface system.

5.
Journal of Kunming Medical University ; (12): 68-71, 2016.
Artigo em Chinês | WPRIM | ID: wpr-514101

RESUMO

Objective To investigate clinical features of chronic actinic dermatitis (CAD) in Kunming of Yunnan Province.Methods From October 2008 to October 2013,CAD in-patients in our hospital were selected and their general conditions,outcomes of photo-sensitive test and photo-patch test were analyzed in details.Results (1) Among 169 CAD patients,gender ratio (male:female) was 8.9:1.The lesions were mainly distributed on the exposed areas.(2) Photo-sensitive tests of 93 patients showed that the average value of UVA-MPPDwas 7.39 JPcm2 and that of UVB-MED was 20.91 mJPcm2.(3) The results of photo-patch test in 83 patients showed that 48 patients (67.8%) had positive reactions in patch test,and the most common contactant was balsam peru.Fifty-eight patients (69.9%) had positive reactions in photo-patch test indicating that the most common contactant in photo-patch test was balsam peru.Conclusions CAD appears mostly in the middle aged and the aged males and the lesions are mainly distributed on exposed areas.The most common contactants in photo-patch test are balsam peru and perfumed compounds.

6.
Chinese Journal of Biochemical Pharmaceutics ; (6): 185-188, 2015.
Artigo em Chinês | WPRIM | ID: wpr-467693

RESUMO

Polycyclic aromatic hydrocarbons ( PAHs) are ubiquitous environmental pollutants, whose carcinogenicity is determinated.The mechanism of their carcinogenicity: PAHs are able to combine with aryl hydrocarbon hydrocarbon receptor ( AhR ) , resulting in some toxicity and carcinogenicity.AhR is a ligand-dependent activation transcription factor, which is activated by a large variety of ligands, regulating the expression of a series of gene involved in metabolism, and participating in important biological processes, such as singal transduction, cell proliferation,differentiation and apoptosis,and so on.Besides, it's closely related with the tumor development.Thus, it will provide a new approach for cancer prevention and treatment to study the role of PAHs and AhR in the development of tumor.

7.
Journal of Biomedical Engineering ; (6): 245-250, 2014.
Artigo em Chinês | WPRIM | ID: wpr-259662

RESUMO

In the present study carried out in our laboratory, we recorded local field potential (LFP) signals in primary visual cortex (V1 area) of rats during the anesthesia process in the electrophysiological experiments of invasive microelectrode array implant, and obtained time evolutions of complexity measure Lempel-ziv complexity (LZC) by nonlinear dynamic analysis method. Combined with judgment criterion of tail flick latency to thermal stimulus and heart rate, the visual stimulation experiments are carried out to verify the reliability of anesthetized states by complexity analysis. The experimental results demonstrated that the time varying complexity measures LZC of LFP signals of different channels were similar to each other in the anesthesia process. In the same anesthesia state, the difference of complexity measure LZC between neuronal responses before and after visual stimulation was not significant. However, the complexity LZC in different anesthesia depths had statistical significances. Furthermore, complexity threshold value represented the depth of anesthesia was determined using optimization method. The reliability and accuracy of monitoring the depth of anesthesia using complexity measure LZC of LFP were all high. It provided an effective method of realtime monitoring depth of anesthesia for craniotomy patients in clinical operation.


Assuntos
Animais , Ratos , Anestesia , Métodos , Potenciais Evocados Visuais , Microeletrodos , Monitorização Fisiológica , Dinâmica não Linear , Estimulação Luminosa , Reprodutibilidade dos Testes , Córtex Visual
8.
Chinese Journal of Information on Traditional Chinese Medicine ; (12)2006.
Artigo em Chinês | WPRIM | ID: wpr-577840

RESUMO

Objective To establish a quality standard for Xiaoer Shengxue granules. Method SHU-Dihuang, yam, Chinese data in Xiaoer Shengxue granules were identified by TLC. Ferrous sulfate in the granule was determined by UV with wavelength at 509 nm. Results SHU-Dihuang, yam, Chinese data could be detected by TLC. Ferrous sulfate showed a good linear relationship at the range of 0.50~2.50 mg/mL, r=0.999 9. The average recovery was 101.3% and RSD was 1.48% (n=5). Conclusion The method is available with a good reproducibility and can be used for the quality control of Xiaoer Shengxue granule.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA