1.
Radiol. bras ; 49(1): 53-55, Jan.-Feb. 2016. graf
Artigo em Português | LILACS | ID: lil-775179

RESUMO

Abstract The present report describes a case where typical findings of traumatic glenohumeral interposition of rotator cuff stumps were surgically confirmed. This condition is a rare complication of shoulder trauma. Generally, it occurs in high-energy trauma, frequently in association with glenohumeral joint dislocation. Radiography demonstrated increased joint space, internal rotation of the humerus and coracoid process fracture. In addition to the mentioned findings, magnetic resonance imaging showed massive rotator cuff tear with interposition of the supraspinatus, infraspinatus and subscapularis stumps within the glenohumeral joint. Surgical treatment was performed confirming the injury and the rotator cuff stumps interposition. It is important that radiologists and orthopedic surgeons become familiar with this entity which, because of its rarity, might be neglected in cases of shoulder trauma.


Resumo O objetivo deste trabalho é relatar um caso com os achados de imagem característicos da lesão traumática do manguito rotador com interposição de múltiplos cotos de tendões do manguito rotador entre a glenoide e o úmero, confirmada cirurgicamente. Esta condição é uma rara complicação do trauma do ombro. Em geral ocorre no trauma de alta energia, frequentemente associada com luxação da articulação glenoumeral. No caso em questão não houve documentação de luxação franca da articulação glenoumeral. As radiografias mostraram aumento do espaço articular, rotação interna do úmero e fratura do coracoide. Nas imagens de ressonância magnética, além das alterações observadas nas radiografias, foi identificada ruptura massiva do manguito rotador com interposição dos cotos dos tendões do supraespinal, do infraespinal e do subescapular no interior da articulação glenoumeral. Foi realizado tratamento cirúrgico confirmando a lesão e a interposição dos cotos do manguito. É importante que radiologistas e ortopedistas estejam familiarizados com esta entidade, que, pela sua raridade, pode ser negligenciada no atendimento do trauma do ombro.

2.
Clinics ; 65(11): 1093-1097, 2010. ilus, tab
Artigo em Inglês | LILACS | ID: lil-571422

RESUMO

OBJECTIVE: To evaluate the intraobserver and interobserver reliability of radial torsion angle measurement using computed tomography. METHODS: Twelve pairs of cadaver radii and 116 forearms from 58 healthy volunteers were evaluated using axial computed tomography sections measured at the level of the bicipital tuberosity and the subchondral region of the radius. During digital imaging, the angle was formed by two lines, one diametrically perpendicular to the radial tubercle and the other tangential to the volar rim of the distal joint surface. Measurements were performed twice each by three observers. RESULTS: In cadaveric bones, the mean radial torsion angle was 1.48º (-6º - 9º) on the right and 1.62º (-6 º - 8º) on the left, with a mean difference between the right and left sides of 1.61º (0º - 8º). In volunteers, the mean radial torsion angle was 3.00° (-17° - 17°) on the right and 2.91° (-16°- 15°) on the left, with a mean difference between the sides of 1.58º (0º - 7º). There was no significant difference between each side. The interobserver correlation coefficient for the cadaver radii measurements was 0.88 (0.72 - 0.96) and 0.81 (0.58 - 0.93) for the right and left radius, respectively, while for the volunteers, the difference was 0.84 (0.77 - 0.90) and 0.83 (0.75 - 0.89), respectively. Intraobserver reliability was high. CONCLUSION: The described method is reproducible and applicable even when the radial tubercle has a rounded contour.


Assuntos
Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Rádio (Anatomia)/fisiologia , Rádio (Anatomia) , Distribuição por Idade , Cadáver , Intervalos de Confiança , Antebraço/fisiologia , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Fatores Sexuais , Estatísticas não Paramétricas , Tomógrafos Computadorizados , Anormalidade Torcional
3.
Rev. bras. cir. plást ; 24(2): 138-144, abr.-jun. 2009. tab, graf, ilus
Artigo em Português | LILACS | ID: lil-526911

RESUMO

A grande maioria das queimaduras de terceiro grau é tratada com a excisão tangencial,seguida da enxertia de pele. No entanto, as deformidades secundárias são frequentes, principalmentenos membros superiores e na cabeça e pescoço. As contraturas causadas pelasqueimaduras graves podem ser tratadas das formas mais diversas. Aquelas limitadas às pequenasáreas podem ser tratadas com zetaplastias, enxertos ou retalhos locais; mas quandoa contratura é extensa é difícil atingir bons resultados com os métodos convencionais. Osautores descrevem a sistematização e a estratégia na reconstrução primária ou secundáriaem pacientes queimados com o emprego de 58 retalhos livres, em 44 pacientes.


Tangential excision is the debridement of necrotic tissue until viable tissue is reached. Thesecond phase of surgical treatment is wound closure. The gold standard of wound coverageis autologus skin grafting. However, results can be disappointing in severe burns that involvethe upper extremity and the neck. Fifty-eight free flaps for 46 patients with deep burns werereviewed retrospectively to determine indication, methods and outcomes.


Assuntos
Humanos , Masculino , Adulto , Feminino , Lactente , Anormalidades Congênitas , Contratura , Microcirurgia , Queimaduras/cirurgia , Retalhos Cirúrgicos , Extremidade Superior , Métodos , Pacientes , Técnicas e Procedimentos Diagnósticos
4.
Acta ortop. bras ; 16(2): 89-92, 2008. ilus, graf, tab
Artigo em Inglês, Português | LILACS | ID: lil-485964

RESUMO

As fraturas do úmero proximal são lesões comuns, levando seus pacientes a importantes limitações funcionais além de algumas complicações. Atualmente existem algumas opções de tratamentos cirúrgicos visando à melhor estabilização da lesão através de técnicas de ostessíntese, dependendo do grau de gravidade da lesão. Dentre eles, tem-se utilizado a placa com parafusos de ângulo fixo para região proximal do úmero, a qual possui o intuito de preservar a integridade biológica da cabeça umeral associada à redução anatômica segura utilizando múltiplos parafusos de fixação com estabilidade angular, permitindo assim a mobilização precoce do membro fraturado. Foram estudados retrospectivamente 11 pacientes com fratura proximal do úmero, tratados com esse modelo de placa entre os anos de 2004 e 2005. Na avaliação funcional foram utilizados o questionário de Constant e o índice DASH. Os resultados sugerem o aparecimento de perda funcional residual no membro superior após esse tipo de trauma, apesar da fixação estável e o tratamento fisioterapêutico.


Proximal humeral fractures are common injuries leading to severe functional restrictions and complications for patients. Today, there are several surgical alternatives aimed at achieving better injury stabilization by means of osteosynthesis techniques, depending on injury severity. One of these is the fixed-angle plate fixation of the proximal humerus. This bone fixation system is intended to preserve the biologic integrity of the humeral head associated with a safe anatomical reduction, employing several fixating screws with angle stability, thereby allowing an early mobilization of the fractured limb. Eleven patients with proximal humeral fractures treated with the method of fixed-angle plate fixation of the proximal humerus in the period of 2004 to 2005 were retrospectively studied. The patients were subjected to the Constant questionnaire and the DASH index for functional assessment. The results showed some residual dysfunction at the upper end after this type of trauma, even using a fixed-angle plate fixation of the proximal humerus, which notably provides a safe fixation, associated to physical therapy.


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Pessoa de Meia-Idade , Placas Ósseas , Fixação Interna de Fraturas/reabilitação , Fraturas do Ombro/reabilitação , Extremidade Superior , Brasil , Fixação Interna de Fraturas/métodos , Fraturas do Ombro/cirurgia , Fraturas do Ombro/diagnóstico , Inquéritos e Questionários , Estudos Retrospectivos
5.
Rev. bras. ortop ; 28(8): 553-8, ago. 1993. ilus, tab, graf
Artigo em Português | LILACS | ID: lil-199630

RESUMO

Os autores avaliaram os resultados do tratamento cirúrgico de 39 pacientes com fraturas da coluna toraco-lombar. Foram utilizadas, como material de fixaçäo hastes de Harrington isoladamente ou associadas a amarrilhos de Luque e placas AO tipo DCP e 4,5mm com parafusos transpediculares. Analisaram o comportamento do segmento vertebral envolvido na fratura, com destaque especial para a perda da correçäo que ocorre tardiamente. Observaram perda da correçäo inicial em 51,3 por cento dos pacientes, que variou de 5§ a 27§. Correlacionaram essa perda de correçäo à lesäo do disco intervertebral, à lesäo do corpo vertebral e à insuficiência dos métodos convencionais de fixaçäo em manter a reduçäo


Assuntos
Humanos , Masculino , Feminino , Criança , Adolescente , Adulto , Pessoa de Meia-Idade , Fraturas da Coluna Vertebral/cirurgia , Vértebras Lombares/cirurgia , Vértebras Torácicas/cirurgia , Seguimentos , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA