Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Adicionar filtros








Intervalo de ano
1.
Journal of Biomedical Engineering ; (6): 272-279, 2023.
Artigo em Chinês | WPRIM | ID: wpr-981539

RESUMO

Accurate source localization of the epileptogenic zone (EZ) is the primary condition of surgical removal of EZ. The traditional localization results based on three-dimensional ball model or standard head model may cause errors. This study intended to localize the EZ by using the patient-specific head model and multi-dipole algorithms using spikes during sleep. Then the current density distribution on the cortex was computed and used to construct the phase transfer entropy functional connectivity network between different brain areas to obtain the localization of EZ. The experiment result showed that our improved methods could reach the accuracy of 89.27% and the number of implanted electrodes could be reduced by (19.34 ± 7.15)%. This work can not only improve the accuracy of EZ localization, but also reduce the additional injury and potential risk caused by preoperative examination and surgical operation, and provide a more intuitive and effective reference for neurosurgeons to make surgical plans.


Assuntos
Humanos , Couro Cabeludo , Mapeamento Encefálico/métodos , Epilepsia/diagnóstico , Eletroencefalografia/métodos , Encéfalo
2.
Chinese Journal of Radiological Medicine and Protection ; (12): 721-725, 2021.
Artigo em Chinês | WPRIM | ID: wpr-910384

RESUMO

Objective:To investigate the influence of low-dose ionizing radiation on the expression level of serum insulin-like growth factor binding protein-3 (IGFBP-3) in radiation workers in hospitals.Methods:183 radiation workers were randomly selected and grouped by work type including interventional radiology ( n=37), nuclear medicine ( n=43), radiotherapy ( n=48), and diagnostic radiology ( n=55). The content of IGFBP-3 in the serum of radiation workers was detected by ELISA assay. Results:It was observed that the expression level of serum IGFBP-3 in the four groups had significant differences ( F=6.056, P<0.05), and the content of serum IGFBP-3 in the interventional radiology group was significantly higher than that of nuclear medicine, radiotherapy, and diagnostic radiology groups ( t= 2.815, 3.611, 3.936, P<0.05). The concentration of IGFBP-3 in the serum of radiation workers among different annual effective dose groups was statistically different ( F=8.380, P<0.05), which gradually increased with the increase of annual effective dose and length of service ( rs=0.202, 0.151, P<0.05). Conclusions:The expression level of serum IGFBP-3 has the potential to be used as a biomarker to reflect the cumulative exposure of long-term chronic low-dose ionizing radiation.

3.
Chinese Journal of Preventive Medicine ; (12): 1496-1499, 2021.
Artigo em Chinês | WPRIM | ID: wpr-922723

RESUMO

A questionnaire was used to investigate the emergency training needs of novel coronavirus pneumonia of disease prevention and control institutions in provinces, deputy provincial level regions and cities specifically designated in the state plan, and the effect evaluation of emergency training activities conducted by Chinese Center for Disease Control and Prevention (China CDC). The results showed that 67.4% of 47 disease prevention and control institutions (31/46) believed that the emergency training at the initial stage of the epidemic should be conducted as soon as possible, and the form of network training should be given priority. The training should focus on the urgently needed technologies such as epidemiological investigation, formulation and response of prevention and control strategies, laboratory testing, etc. The teaching materials should highlight pertinence and practicability and be presented in the form of electronic video. The average satisfaction score of the video training conducted by China CDC was (8.81±1.125) and the score of audio-video courseware was (8.97±0.893). The needs analysis and evaluation of novel coronavirus pneumonia prevention and control in disease prevention and control institutions could provide reference for the follow-up training and improve the emergency training management.


Assuntos
Humanos , COVID-19 , China/epidemiologia , Pneumonia/prevenção & controle , SARS-CoV-2 , Inquéritos e Questionários
4.
Chinese Journal of Radiological Medicine and Protection ; (12): 746-752, 2020.
Artigo em Chinês | WPRIM | ID: wpr-868513

RESUMO

Objective:To explore the feasibility of using a High-Throughput Chromosome Automatic Scanning System (Metafer 4) to carry out automatic micronucleus detection for radiation workers.Methods:A total of 2 005 radiation workers selected were divided into five groups in terms of diagnostic radiology, radiotherapy, nuclear medicine, interventional radiology and industrial application.The Metafer 4 was used to assay micronuclei in peripheral blood lymphocytes from the subjects, with the factors affecting micronuclei analyzed. A total of 200 micronucleus samples collected by stratified random sampling were manually assayed for comparison of micronuclei frequency and detection efficiency between automatic and manual analysis.Results:The mean micronuclei frequency in 2 005 radiation workers were measured to be (0.92±0.02) ×10 -3. There was significant difference in the frequencies of micronuclei among the five groups ( χ2=11.054, P<0.05), with higher micronuclei frequency in interventional radiology group(1.00±0.03) ×10 -3 than in other groups ( χ2=5.568, 5.334, 7.689, P<0.05). Statistically significant difference could be observed in annual effective dose, length of service and micronuclei frequency among the radiation workers in different medical applications ( F=3.026, χ2=11.582, 8.878, P<0.05). A positive correlation between annual effective dose and micronucleus frequency was shown by Pearson analysis ( r=0.106, P<0.05). Multiple linear regression analysis showed that the automatic assay-based micronuclei frequencies were associated with length of service and work categories( r=9.485×10 -6, 5.660×10 -5, P<0.05), significantly lower when compared with manual analysis ( χ2=169.259, P<0.05). There was a consistency (ICC=0.713, P<0.05) between the two assay methods, but automatic analysis can increase the assayed micronucleus frequency by about 5 folds. Conclusions:The micronucleus frequency tested by automatic detection reflects genetic damage from low-dose chronic radiation exposure, and there may be feasibility of using automatic analysis to assay micronucleus of radiation workers.

5.
Chinese Journal of Radiological Medicine and Protection ; (12): 278-283, 2020.
Artigo em Chinês | WPRIM | ID: wpr-868443

RESUMO

Objective:To explore the influence factors of chromosomal aberration levels in radiation workers in hospitals.Methods:Two hundred and fourteen age- and sex- matched hospital radiation workers were recruited by stratified random sampling method. According to the job title, the individuals were divided into four groups including diagnostic radiology group ( n=57), radiotherapy group ( n=49), nuclear medicine group ( n=52) and interventional radiology group ( n=56). Chromosomal aberrations in peripheral blood lymphocytes from the subjects were measured using conventional cytogenetic analysis method, and the influence factors of chromosomal aberrations were analyzed. Results:There was significant difference in the frequencies of acentric fragment, translocation and total chromosome-type aberrations among the four groups ( χ2=9.906, 19.965, 32.824, P<0.05), and the rates of aberrations were significantly higher in the interventional radiology group and the nuclear medicine groups than those in the diagnostic radiology (interventional group: χ2=4.711, 10.798, 10.845, P<0.05; nuclear medicine group: χ2=3.853, 7.674, 7.708, P<0.05) and the radiotherapy groups (interventional group: χ2=9.209, 9.772, 21.330, P<0.05; nuclear medicine group: χ2=8.010, 6.969, 10.812, P<0.05). The rates of translocation and total aberrations ( χ2=7.706, 6.667, P<0.05) and the frequencies of acentric fragment, translocation and total aberrations ( χ2=12.263, 15.360, 21.478, P<0.01) were dependent on the length of service and the dose among different groups. The rates of translocation and total aberrations significantly increased along with exposure doses ( r=0.347, 0.263, P<0.01). Poisson regression analysis indicated that the job titles and annual effective dose partly affected the levels of chromosomal aberrations[ IRR=1.797 (nuclear medicine group), 2.136 (interventional group) and 1.422 (0.5-1 mSv group); P<0.05]. Conclusions:The frequencies of chromosomal aberrations in the radiation workers of interventional and nuclear medicine groups remain higher levels in hospital, thus it is necessary to strengthen the radiation protection on these radiation workers.

6.
Chinese Journal of Radiological Medicine and Protection ; (12): 253-257, 2018.
Artigo em Chinês | WPRIM | ID: wpr-708051

RESUMO

Objective To explore the influence of long-term low-dose ionizing radiation on 8-hydroxy-2-deoxyguanosine(8-OHdG) level in the serum of radiation workers in hospitals.Methods 307 age-and sex-matched hospital radiation workers were recruited by stratified random sampling method.After deleting the subjects without dosage information,230 individuals were divided into four groups according to their job title [including diagnostic radiology (n =75),radiotherapy (n =60),nuclear medicine (n =41) and interventional radiology (n =54)].Serum 8-OHdG level was measured by ELISA assay.Results According to the statistical analysis,there was significant difference in the serum 8-OHdG level among four groups (F =9.071,P < 0.05),and the content of serum 8-OHdG was significantly higher in the interventional radiology group than that in the groups of diagnostic radiology,radiotherapy and nuclear medicine (t =-4.473,-3.011,-2.189,P < 0.05).There were significant differences in serum 8-OHdG level among different dose groups and working period groups(F =7.659,3.058,P < 0.05).The serum 8-OHdG levels significantly increased along with exposure dose and working period (r =0.300,0.142,P < 0.05).Conclusions Serum 8-OHdG may be a potential biomarker of oxidative DNA damage in radiation workers exposed to low-dose ionizing radiation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA