Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Adicionar filtros








Intervalo de ano
1.
Journal of Pharmaceutical Practice ; (6): 364-367, 2020.
Artigo em Chinês | WPRIM | ID: wpr-823106

RESUMO

Objective To establish a fast detection method of sodium aescinate by using near infrared (NIR) spectroscopy analysis method for the determination of the content of sodium aescinate for injection. Methods OPUS software was used to optimize the collected spectrum. PLS algorithm and factorization algorithm were used to establish quantitative model and qualitative model. Results The correlation coefficient of the quantitative model reached 0.9926, the RMSECV deviation was 0.253. The deviation between the predicted value of the sample and the true measured value was less than 5%, which could accurately predict the content of sodium aescinate. Conclution The qualitative model can effectively distinguish the samples of other varieties that have not participated in the modeling, and provide a reference for the rapid screening of the drug.

2.
China Pharmacist ; (12): 389-391, 2017.
Artigo em Chinês | WPRIM | ID: wpr-507544

RESUMO

Objective:To establish a method for the determination of chloramphenicol and hydrocortisone in chloramphenicol hy-drocortisone ear drop. Methods:An HPLC method was used with a Shiseido SPOLAR C18 column (250 mm ′4. 6 mm, 5 mm). The mobile phase was 0. 01 mol·L-1 sodium heptane sulfonate buffer solution (6. 8 g potassium dihydrogen phosphate was dissolved in 0. 01 mol · L-1 heptane sodium sulfonate buffer solution and diluted to 1000 ml, 5 ml triethylamine was added and mixed, and then the pH was adjusted to 2. 5 by phosphoric acid)-methanol (40︰60). The column temperature was 30℃ and the flow rate was 1. 0 ml · min-1 . The detection wavelength was 245 nm and the injection volume was 10 μl. Results: Chloramphenicol and hydrocortisone had a good linear relationship within the range of 50. 26-753. 84 μg · ml-1 ( r =0. 9996 ) and 10. 93-163. 92 μg · ml-1 ( r =1. 0000), respectively. The average recovery of chloramphenicol was 100. 21% and RSD was 0. 48%(n=9). The average recovery of hydrocortisone was 100. 82% and RSD was 0. 37% (n=9). Conclusion:The method has the advantages of high specificity, good reproducibility and high precision, and can be used as a method for the determination of chloramphenicol and hydrocortisone in chlor-amphenicol hydrocortisone ear drop.

3.
Journal of Southern Medical University ; (12): 382-385, 2010.
Artigo em Chinês | WPRIM | ID: wpr-269543

RESUMO

<p><b>OBJECTIVE</b>To investigate the characteristic findings of an anomalous systemic arterial supply to the lung without the pulmonary artery on spiral CT and discuss its nomenclature.</p><p><b>METHODS</b>Four cases of anomalous systemic arterial supply to the left basal segment of the lung without the pulmonary artery were retrospectively reviewed with analysis of the characteristic CT findings.</p><p><b>RESULTS</b>On spiral CT scans, the involved left lower lung including the entire left basal segments (n=2), the lateral and posterior basal segment (n=1), and the anterior, medial, and posterior basal segment (n=1) had mild volume loss and areas of ground-glass opacity but with normal bronchial trees. The absence of the entire or part of the basal segments of the normal left lower lobar pulmonary artery, anomalous systemic artery originating from the abdominal aorta, diffuse dilatation of the systemic arterial branches distributed in the basal segments of the left lower lobe, and left lower pulmonary venous drainage into left atrium were found in all these patients.</p><p><b>CONCLUSION</b>This anomaly presents with characteristic findings on chest spiral CT, for which the nomenclature of local absent pulmonary artery better shows the characteristics of the disease.</p>


Assuntos
Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Aorta Abdominal , Anormalidades Congênitas , Diagnóstico por Imagem , Artéria Pulmonar , Anormalidades Congênitas , Diagnóstico por Imagem , Estudos Retrospectivos , Terminologia como Assunto , Tomografia Computadorizada Espiral
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA