Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Journal of Southern Medical University ; (12): 620-624, 2018.
Artigo em Chinês | WPRIM | ID: wpr-690420

RESUMO

<p><b>OBJECTIVE</b>To explore the association of plasma level of advanced oxidation protein products (AOPPs) with Framingham risk score in type 2 diabetic patients without vascular diseases.</p><p><b>METHDOS</b>This cross-sectional study was conducted among type 2 diabetic patients without vascular diseases recruited from 3 affiliated hospitals of Southern Medical University between March, 2010 and May, 2011, with age- and gender-matched healthy individuals as the control group. The demographic data were collected from all the participants, and the biochemical indexes and plasma levels of AOPPs were examined. The risk of cardiovascular disease in 10 years was assessed for all the participants based on their Framingham risk scores.</p><p><b>RESULTS</b>A total of 112 diabetic patients and 49 healthy subjects were enrolled in this study. The diabetic patients had significantly higher body mass index (BMI), blood glucose, triglyceride, low-density lipoprotein (LDL), plasma AOPPs and Framingham risk score but lower high-density lipoprotein level than the control subjects. Spearman correlation analysis showed that plasma level of AOPPs was positively correlated with the Framingham risk score (r=-0.44, P<0.001), and further multiple linear regression analysis suggested that plasma AOPPs level was independently correlated with the Framingham risk score (β0.305, P<0.001).</p><p><b>CONCLUSION</b>Type 2 diabetic patients without vascular diseases have significantly higher plasma levels of AOPPs and are at a greater risk of cardiovascular events in 10 years than healthy individuals. Plasma AOPPs are positively correlated with the Framingham risk score, suggesting the value of plasma AOPPs level in predicting the risk of cardiovascular events in these patients.</p>

2.
China Journal of Orthopaedics and Traumatology ; (12): 884-887, 2015.
Artigo em Chinês | WPRIM | ID: wpr-251618

RESUMO

<p><b>OBJECTIVE</b>To study on the reliability of the Akagi line as a reference axis to guide for rotational alignment of the proximal tibial component in total knee arthroplasty (TKA) the rotational alignment reference bony landmarks of the proximal tibial component on magnetic resonance image (MRI) were measured.</p><p><b>METHODS</b>From January 2010 to December 2013, 80 normal knees of Chinese volunteers including 35 males and 45 females with an average age of (35.4±6.1) years were reviewed. The images of the knees were obtained by MRI. The surgical epicondylar axis (STEA) was identified in the femoral transverse sections and then was projected to the side of tibia, forming the SETA'. A line connecting the medial border of the patellar tendon and the middle of the posterior cruciate ligament insertion (Akagi line) and its vertical line (AK), as well as a line connecting the medial 1/3 of the patellar tendon and the middle of the posterior cruciate ligament insertion and its vertical line (AP), were identified in the tibial transverse sections. The angles were measured between the AK, AP and STEA'.</p><p><b>RESULTS</b>The angle between AK and STEA' was (0.59±2.07)°, and there was no significant difference between the two lines (t=-2.54, P=0.13). The mean angle between AP and STEA' was (3.21±2.04)°, and there was a significant difference between the two lines (t=14.05, P<0.05). There was a significant difference between the AK and AP (t=-11.68, P<0.05).</p><p><b>CONCLUSION</b>The reliability of the Akagi line as a reference axis to guide for rotational alignment of the proximal tibial component in TKA is good.</p>


Assuntos
Adolescente , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Artroplastia do Joelho , Métodos , Reprodutibilidade dos Testes , Rotação , Tíbia , Cirurgia Geral
3.
Chinese Journal of Medical Education Research ; (12): 1141-1143, 2014.
Artigo em Chinês | WPRIM | ID: wpr-669816

RESUMO

Objective To explore the application effects of simulation diagnosis teaching in practical teaching of obstetrics and gynecology.Methods Students were divided into simulation teaching group(n=46) and traditional teaching group(n=46).Survey was conducted among simulation teaching group and traditional teaching group concerning clinical teaching of obstetrics and gynecology.Teaching effects were evaluated by questionnaire and examination.SPSS 13.0 statistics software was used to do the analysis.Enumeration data was analyzed by chi-square test while measurement data by t test.P<0.05 stands for statistically significant difference.Results There were significant differences in improving students' clinical thinking and practical ability between two groups(P<0.05).Satisfaction degree of simulation teaching group was significantly higher than that of traditional teaching group.Examination results of simulation teaching group was significantly higher than that of traditional teaching group(theoretical exam:P=0.001; operational exam:P=0.000).Conclusions Simulation diagnosis teaching can provide students more opportunities to practice and improve students' clinical thinking ability and clinical practice ability.

4.
China Journal of Orthopaedics and Traumatology ; (12): 918-921, 2011.
Artigo em Chinês | WPRIM | ID: wpr-347004

RESUMO

<p><b>OBJECTIVE</b>To study the morbidity factors of bilateral intertrochanteric fractures by analyzing medical records, so as to provide evidences for preventing the multiple intertrochanteric fractures.</p><p><b>METHODS</b>From Janurary 2000 to June 2009, 68 patients with bilateral intertrochanteric fractures were studied, including 31 males and 37 females, ranging in age from 42 to 95 years with an average age of 75 years. There were type A1 in 24 hips, type A2 in 96 hips, and type B3 in 16 hips. One hundred and twenty-eight hips had received surgical treatment, 8 hips were treated with conservative method. On the first injury, 67 patients discharged after treatment, 1 patients discharged after treatment in other department. On the second injury, 58 patients discharged after treatment, 2 patients died of complications, 8 patients dischagred after treatment in other department. The risk factors including age, cause of injury, fractures type, complications, osteoporosis and treatment were analyzed.</p><p><b>RESULTS</b>The average age of two fractures were (73.6 +/- 9.25) and (76.7 +/- 6.74) years; the major injury cause was fall; the A2-type fractures went up to 80.88% on the secondary injury;and the proportion of complications was high, mainly geriatric cognitive disorders, hemiplegic paralysis, and dysopia. Bone mineral density measurement of 16 cases showed marked osteoporosis.</p><p><b>CONCLUSION</b>Osteoporosis and fall injury contribute mostly to the multiple intertrochanteric fractures. Complication was the dominating risk factor. Treatment of osteoporosis, intensive care, postoperative rehabilitation and effective initial surgery are the key to prevent the secondary intertrochanteric fractures in old people.</p>


Assuntos
Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Acidentes por Quedas , Fraturas do Quadril , Morbidade , Osteoporose , Fatores de Risco
5.
Chinese Journal of Experimental Ophthalmology ; (12): 834-838, 2011.
Artigo em Chinês | WPRIM | ID: wpr-635711

RESUMO

BackgroundIt is important to measure the corneal curvature, anterior chamber depth (ACD) and axial length accurately for calculating IOL power. The interchange outcomes from different measuring methods and apparatus will cause unreliable IOL power. ObjectiveThe present study was to compare the differences of corneal curvature, anterior chamber depth (ACD) measured by IOLMaster and Orbscan Ⅱbefore and after laser in situ keratomileusis(LASIK) and further compare the axial length measured by IOLMaster and A-ultrasound. Methods One hundred and thirty eyes from 65 consecutive myopic patients before LASIK and 56 eyes of 28 cases with 1-month follow-up duration after LASIK in Henan Eye Institute were enrolled in this study. The K value, ACD between IOLMaster and Orbscan Ⅱ as well as results of axial length between IOLMaster and A-ultrasound were compared by using paired t test. The agreements of the measured values among IOLMaster, Orbscan Ⅱ and A-ultrasound were evaluated using Bland-Altman plot. ResultsBefore LASIK,the K value measured by IOLMaster,Orbscan Ⅱ were ( 43.32 ± 1.52 ) D and ( 42.99 ± 1.45 ) D respectively with the difference value of( 0. 33 ±0. 03 ) D, showing a significant difference(t=10. 380,P=0.000) and a positive relation between them(r=0.971,P=0.000). After LASIK,the K value measured by IOLMaster, Orbscan Ⅱwere(39. 02±2. 14) D and ( 38.91 ±2. 04) D with the difference value (0. 12±0. 33 ) D, presenting a significant differences between them (t =2.715, P =0.009). Bland-Altman plots indicated the disagreement in K value and uninterchangeable. Before LASIK, the ACD measured by IOLMaster,Orbscan Ⅱ and A-ultrasound were ( 3.72 ± 0. 22 ) mm, ( 3.69 ±0. 22 ) mm and ( 3.75± 0.27 )mm respectively and no significant differences were found between them (P > 0. 05 ). Axial length measured by IOLMaster significantly prolonged in comparison with A-ultrasound(25.59± 1. 01 mm vs 25.22±0.99 mm ) , and the difference was( -0. 37 ±0. 30 ) mm, showing significant difference ( t =- 14. 098, P =0. 000 ) and positive correlation ( r =0. 954, P =0. 000 ). Axial length values measured by IOLMaster were ( 25.54 ± 1.05 ) mm in preoperation and ( 25.48 ± 1.01 ) mm in postoperation with the difference (0.052±0. 412)mm, showing statistically insignificant difference between them (t=0. 946,P=0. 348). ConclusionsKeratometries measured by IOLMaster,Orbscan Ⅱ are much more different. Therefore,these two methods are not recommended to use interchangely. ACD measured by IOLMaster,Orbscan Ⅱ and A ultrasound are proved to obtain the similar results and is clinically interchange. Axial length measured by IOLMaster is longer than that measured by A-ultrasound.

6.
China Journal of Orthopaedics and Traumatology ; (12): 668-671, 2010.
Artigo em Chinês | WPRIM | ID: wpr-332866

RESUMO

<p><b>OBJECTIVE</b>To compare therapeutic effects between clavicular hook plate and tension band fixation for the treatment of Allman type II to III sternoclavicular joint dislocations.</p><p><b>METHODS</b>A retrospective survey was analyzed from May 2000 to September 2008. A total of 31 patients with Allman type II to III sternoclavicular joint dislocations were followed up. Sixteen patients were fixed with the clavicular hook plate (Group A) including 11 males and 5 females, with a mean age of (37.4 +/- 7.3) years. Fifteen patients were treated with tension band fixation (Group B) including 9 males and 6 females, with a mean age of (35.6 +/- 5.1) years. The indexes of intra-operation and during the hospital stay, the clinical outcomes and postoperative complications were statistically compared.</p><p><b>RESULTS</b>All the patients were followed up for 12 to 37 months, with an average of 20 months. There was no significant differences in data of operative time, blood loss and length of incision between the two group (P > 0.05); however, the economic cost was significantly much more in Group A (P < 0.01). Also, there was statistically difference in the incidence of complications between the two groups (P = 0.023), which were 2 patients in Group A and 8 patients in Group B. According to Rockwood evaluation criteria, in group A, 13 patients got an excellent result, 2 good and 1 poor; in group B, 10 patients got an excellent result, 3 good, 1 poor and 1 bad. There were no statistical difference in good and excellent rate.</p><p><b>CONCLUSION</b>The clavicular hook plate for the treatment of Allman type II to III sternoclavicular joint dislocation is believed to be as good as tension band fixation, but there are fewer complications and in favor of early exercise.</p>


Assuntos
Adulto , Feminino , Humanos , Masculino , Placas Ósseas , Estudos de Casos e Controles , Fixação Interna de Fraturas , Métodos , Luxações Articulares , Cirurgia Geral , Dispositivos de Fixação Ortopédica , Articulação Esternoclavicular , Ferimentos e Lesões
7.
China Journal of Orthopaedics and Traumatology ; (12): 536-538, 2008.
Artigo em Chinês | WPRIM | ID: wpr-307059

RESUMO

<p><b>OBJECTIVE</b>To evaluate the safety and reliability of percutaneous internal fixation for pelvic ring injuries with cannulated screws.</p><p><b>METHODS</b>Forty-eight patients (21 male and 27 female, aged from 17 to 61 years with an average age of 38 years) with unstable pelvic ring injuries were treated with closed reduction and percutaneous cannulated screws fixation under C-arm fluoroscopic guidance. According to Tile's classification, the patients were classified into type B1 in 4 cases, B2.1 in 8, B2.2 in 10, B3 in 4, C1 in 11, C2 in 7 and C3 in 4. Among them, 39 patients were treated with anterior and posterior fixation, 4 were treated with anterior fixation, and 5 were treated with posterior fixation alone. Anteroposterior, inlet and outlet X-ray radiographs and CT scans of the pelvis were taken preoperatively to evaluate the stability and deformities, and after surgery the plain radiographs and CT scans were taken to evaluate the reduction and the location of screws.</p><p><b>RESULTS</b>The average operative time was 55 minutes (range, 15 to 95 minutes), and the average intraoperative blood loss was 60 ml (range, 15 to 150 ml), no patient accepted blood transfusion during or after operation. All 48 patients were inserted 157 cannulated screws (mean 3.3, range 2 to 8 per patient). Forty-two patients (135 screws) underwent postoperative pelvic CT scan and 91.11% (123 screws) of them was considered in optimal location; 7 screws penetrated the wall of pelvis and acetabulam because of overlength (<0.5 cm) or deviation, 5 screws interfered with the sacral canal or foramen. Fortunately, these 12 screws did not cause any symptom to the patients. The average follow-up period was 13 months (range 8 to 49 months), the displacement of injured pelvis was satisfactorily corrected in 45 patients (93.75%) and the fractures were healed at one stage. Among all patients, 40 cases (83.33%) had returned to their original works, 4 were still in the process of recovery at the last follow-up and the other 4 were unemployed as sciatic nerve injury or amputation. According to Lindahl improved standard of functional assessment of pelvic injury, the result was excellent in 35 cases, good 10 and fair 3, the average score was 78.7.</p><p><b>CONCLUSION</b>With better understanding of the pelvic anatomy, and under C-arm fluoroscopic guidance, treatment of closed reduction and percutaneous cannulated screw internal fixation for unstable pelvic ring injuries is a safe, reliable and feasible method. The clinical outcome is satisfactory.</p>


Assuntos
Adolescente , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Parafusos Ósseos , Fixação Interna de Fraturas , Métodos , Procedimentos Cirúrgicos Minimamente Invasivos , Métodos , Ossos Pélvicos , Ferimentos e Lesões
8.
China Journal of Chinese Materia Medica ; (24): 511-513, 2005.
Artigo em Chinês | WPRIM | ID: wpr-279127

RESUMO

<p><b>OBJECTIVE</b>To study the chemical constituents of the corm of the planted Cremastra appendiculata.</p><p><b>METHOD</b>The compounds were isolated by column chromatography with silica gel and Sephadex LH-20, and their structures were elucidated by means of spectroscopic methods including 2D NMR techniques.</p><p><b>RESULT</b>Six compounds were isolated, and identified as isohircinol (I), flavanthrinin (II), p-hydroxyphenylethyl alcohol (III), 3,4-dihydroxyphenylethyl alcohol (IV), daucosterol (V), beta-sitosterol (VI).</p><p><b>CONCLUSION</b>These compounds were not previously isolated from this plant, and isohircinol (I) was obtained from natural source for the first time.</p>


Assuntos
Orchidaceae , Química , Álcool Feniletílico , Química , Plantas Medicinais , Química , Sitosteroides , Química
9.
China Journal of Chinese Materia Medica ; (24): 1827-1830, 2005.
Artigo em Chinês | WPRIM | ID: wpr-287278

RESUMO

<p><b>OBJECTIVE</b>To investigate the chemical constituents from the tuber of the planted Cremastra appendiculata.</p><p><b>METHOD</b>The compounds were isolated by column chromatography over silica gel, Sephadex LH-20 and RP-HPLC, and their structures were elucidated on the basis of spectroscopic analysis.</p><p><b>RESULT</b>Eight compounds were isolated, and identified as cirrhopetalanthrin (I), 7-hydroxy-4-methoxyphenanthrene-2-O-beta-D-glucoside (II), 4-(2-hydroxyethyl)-2-methoxyphenyl-1-O-beta-D-glucopyranoside (III), tyrosol 8-O-beta-D-gluco-pyranoside (IV), vanilloloside (V), p-hydroxybenzaldehyde (VI), sucrose (VII), adenosine (VIII).</p><p><b>CONCLUSION</b>These compounds are isolated from this plant for the first time. All compounds were evaluated against human colon cancer (HCT-8), human hepatoma (Bel7402), human stomach cancer(BGC-823), human lung adenocarcinoma (A549), human breast cancer (MCF-7), and human ovarian cancer (A2780) cell lines, and cirrhopetalanthrin (I) showed non-selective moderate cytotoxicity with IC50 values of 8.4-13.3 micromol x L(-1), and other compounds were inactive.</p>


Assuntos
Humanos , Adenosina , Química , Farmacologia , Antineoplásicos Fitogênicos , Química , Farmacologia , Benzaldeídos , Química , Farmacologia , Linhagem Celular Tumoral , Concentração Inibidora 50 , Orchidaceae , Química , Raízes de Plantas , Química , Plantas Medicinais , Química , Sacarose , Química , Farmacologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA