Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Adicionar filtros








Intervalo de ano
1.
Chinese Journal of Cardiology ; (12): 137-141, 2022.
Artigo em Chinês | WPRIM | ID: wpr-935117

RESUMO

Objective: To evaluate the safety and efficacy of transcatheter aortic valve implantation (TAVI) with the novel Prizvalve® system in treating severe aortic stenosis. Methods: This is a single-center, prospective, single-arm, observational study. A total of 11 patients with severe aortic stenosis with high risk or inappropriate for conventional surgical aortic valve replacement (SAVR) were included, and TAVI was achieved with the Prizvalve® system between March 2021 and May 2021 in West China Hospital. Transthoracic echocardiography (TTE) was performed immediately after prosthesis implantation to evaluate mean transaortic gradient and maximal transaortic velocity. The device success rate was calculated, which was defined as (1) the device being delivered via the access, deployed, implanted and withdrawn, (2) mean transaortic gradient<20 mmHg (1 mmHg=0.133 kPa) or a maximal transaortic velocity<3 m/s post TAVI, and without severe aortic regurgitation or paravalvular leak post TAVI. TTE was performed at 30 days after the surgery, and all-cause mortality as well as the major cardiovascular adverse events (including acute myocardial infarction, disabling hemorrhagic or ischemic stroke) up to 30 days post TAVI were analyzed. Results: The age of 11 included patients were (78.1±6.3) years, with 8 males. A total of 10 patients were with NYHA functional class Ⅲ or Ⅳ. Devices were delivered via the access, deployed, implanted and withdrawn successfully in all patients. Post-implant mean transaortic gradient was (7.55±4.08) mmHg and maximal transaortic velocity was (1.78±0.44) m/s, and both decreased significantly as compared to baseline levels (both P<0.05). No severe aortic regurgitation or paravalvular leak was observed post TAVI. Device success was achieved in all the 11 patients. No patient died or experienced major cardiovascular adverse events up to 30 days post TAVI. Mean transaortic gradient was (9.45±5.07) mmHg and maximal transaortic velocity was (2.05±0.42) m/s at 30 days post TAVI, which were similar as the values measured immediately post TAVI (both P>0.05). Conclusions: TAVI with the Prizvalve® system is a feasible and relatively safe procedure for patients with severe aortic stenosis and at high risk or inappropriate for SAVR. Further clinical studies could be launched to obtain more clinical experience with Prizvalve® system.


Assuntos
Idoso , Idoso de 80 Anos ou mais , Humanos , Masculino , Valva Aórtica , Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca , Estudos Prospectivos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA