Chinese Journal of Radiation Oncology ; (6): 916-919, 2018.
Artigo em Chinês | WPRIM | ID: wpr-708290

RESUMO

Objective Because of statistical noise in Monte Carlo dose calculations,the effective point doses may not be accurately calculated.A user-defined sphere volume was adopted to substitute the effective point to take sphere sampling around the effective point,which minimize the random errors and improve the accuracy of statistical dose.Methods Direct dose measurements were performed at 0°and 90° using a 0.125 cm3 Semiflex ionization chamber (IC) 31010 isocentrically placed in the center of a homogeneous Cylindric sliced RW3 phantom (PTW,Germany).In the scanned CT phantom series,the sensitive volume length of the IC (6.5 mm) was delineated and the isocenter was defined as the simulated effective point.All beams were simulated in the treatment planning system (TPS) in accordance to the measured model.The grid spacing was calculated by 2 mm voxels and the relative standard deviation should be ≤ 0.5%.The statistical and measured doses were statistically compared among three IC models with different electron densities (ED;esophageal lumen ED =0.210 g/cm3 for model A,air ED =0.001 g/cm3 for model B and the default CT scanned ED for model C) at different sampling sphere radius (2.5,2.0,1.5 and 1.0 mm) to evaluate the effect of Monte Carlo.calculation uncertainty upon the dose accuracy.Results In the Monaco TPS,the statistical value was in the highest accordance with the measured value with an absolute average deviation of 0.49% when the IC was set as esophageal lumen ED =0.210 g/cm3 and the sampling sphere radius was 1.5 mm.When the IC was set as air ED=0.001 g/cm3 and default CT scanned ED,and,the recommended statistical sampling sphere radius was 2.5 mm,the absolute average deviations were 0.61% and 0.70%.Conclusion In the Monaco TPS,the calculation model with an ED of 0.210 g/cm3 and a sampling radius of 1.5 mm is recommended for the ionization chamber 31010 to substitute the effective point dose measurement to decrease the random stochastic errors of Monte Carlo.

2.
Chinese Journal of Radiation Oncology ; (6): 862-866, 2016.
Artigo em Chinês | WPRIM | ID: wpr-495485

RESUMO

Objective To figure out the optimal parameters of a volumetric modulated arc therapy ( VMAT) plan for cervical and upper esophageal cancer by quality evaluation of VMAT plans with different parameters, and to provide a reference for the design of clinical VMAT treatment plan. Methods Ten patients with cervical esophageal cancer and ten patients with upper esophageal cancer were enrolled as subjects. The Nucletron Oncentra 4. 3 treatment planning system was used to generate plans for Elekta Synergy VMAT accelerator. Six VMAT plans were made with variation in the gantry angle ( 2°, 3°, and 4°), the maximum delivery time (80 s, 110 s, and 150 s), and the collimator angle (0° and 45°). The doses to the planning target volume and organs at risk were analyzed by paired t test. Results For cervical and upper esophageal cancer, the quality of VMAT plans with a collimator angle of 45° was better than those with a collimator angle of 0°(P=0. 003?0. 007). For cervical esophageal cancer, there was no significant difference in quality between VMAT plans with a maximum delivery time of 110 s or 150 s and those with a maximum delivery time of 80 s ( P>0. 05 );for upper esophageal cancer, there was also no significant difference in quality between VMAT plans with three different maximum delivery times ( P>0. 05 ) . For cervical esophageal cancer, the VMAT plans with a gantry angle of 3° had a better quality than those with a gantry angle of 2° or 4°(P=0. 010?0. 048). For upper esophageal cancer, the VMAT plans with a gantry angle of 3° had a better quality than those with a gantry angle of 4° ( P=0. 010?0. 048) . Compared with those with a gantry angle of 2° , the VMAT plans with a gantry angle of 3° had a slightly better dose distribution in the target volume ( P=0. 046 ) , but a slightly higher dose to lung tissue ( V25 and V30 , P=0. 007 and 0. 026) . Conclusions The optimal initial parameters of a VMAT plan for cervical and upper esophageal cancer are a collimator angle of 45°, a maximum delivery time of 80 s, and a gantry angle of 3°.

3.
Chinese Journal of Radiation Oncology ; (6): 740-744, 2016.
Artigo em Chinês | WPRIM | ID: wpr-497972

RESUMO

Objective To investigate the optimization of therapeutic regimen through the adjustment of the minimum sub-field area in intensity-modulated radiotherapy (IMRT) for cervical cancer,under the premise of no influence on the dose to target volume or organs at risk.Methods A total of 12 patients with pathologically confirmed cervical cancer were enrolled,and the prescribed dose to the planning target volume (PTV) was 50 Gy in 25 fractions.The Pinnacle 8.0m treatment planning system was used for all patients,and 16 IMRT plans were developed for each patient,with the application of 9 evenly distributed fixed incidence directions (0°,40°,80°,120°,160°,200°,240°,280°,and 320°),a minimum sub-field number of 80,and a minimum sub-field hop count (MU) of 5 MU.The range of sub-field area was 2-81 cm2.Direct machine parameter optimization was used for inverse-planned optimization calculation,and all the plans met the requirements of the clinical prescribed dose.The dose-volume histogram was used to evaluate the dose distribution in target volume and organs at risk.Results With the sub-field area increasing from 2 cm2 to 81cm2,the total hop count of IMRT plan was reduced from (1405±170) MU to (490±47) MU (P=0.000),and when the sub-field area increased above 6 cm×6 cm,the total hop count was reduced significantly (P=0.000).In the IMRT plan with a minimum sub-field area of 2-49 cm2,there was no significant difference in dose between the target volume and the organs at risk (P>0.05).The dose to the rectum,the bladder,and both femoral heads showed no significant differences across the IMRT plans with different minimum sub-field areas (P>0.05).Conclusions When the Pinnacle 8.0m treatment planning system is used to develop IMRT plans for cervical cancer,the requirements for clinical dose can still be met with a minimum sub-field area reaching 7 cm×7 cm,and there are significant reductions in sub-field hop count and total hop count.

4.
Chinese Journal of Radiation Oncology ; (6): 618-621, 2016.
Artigo em Chinês | WPRIM | ID: wpr-496875

RESUMO

Objective To construct the uniform electron density couch model (model A ED =0.25) and two components non uniform electron density couch model (model B FD =0.5and foam core=0.1) in the Monaco treatment planning system for the iBEAM(R) evo Extension 415,and to compare which model can better quantify the treatment couch influence on radiation dose.Methods Phantom was positioned in the center of the couch,the attenuation of the couch was evaluated with 6 MV for a field size of 10 cm× 10 cm.Dose measurements of couch attenuation were performed at gantry angles from 180.0° to 122.8°,using a 0.125cc semiflex ionization chamber (PTW),isocentrically placed in the center of a homogeneous cylindrical phantom.Each experimental setup was first measured on the linear accelerator and then reproduced in the TPS.By adjusting the relative-to water electron density (ED) values of the couch,the measured attenuation was replicated.The model accuracies of the model A and model B were evaluated by comparing the measured and calculated results at the minimum computational grid (2 mm) and maximum computing grid (5 mm),respectively.Results The maximum measured and calculated percentage deviation for the central phantom position was 4.01%.The couch model was included in the TPS with a uniform ED of 0.25 or a 2 component model with a fiber ED=0.5 and foam core ED=0.1.For model A and B under 2 and 5 mm voxel grid size,the mean absorbed dose with couch was reduced to 0.61%,0.84%,0.71% and 0.92%from 2.8% without couch.Conclusions Model A has a good agreement between measured and calculated dose distributions for all different voxel grid sizes and gantry angles.It can accurately describes the dose perturbations due to the presence of the couch and should therefore be used during treatment planning.

5.
Journal of International Oncology ; (12): 785-788, 2014.
Artigo em Chinês | WPRIM | ID: wpr-466578

RESUMO

Objective Comparing the dosimetric characteristics of volumetric modulated arc therapy (VMAT) and constant dose rate intensity modulated arc therapy (IMAT) in esophagus cancer to evaluate the performance of the two different arc therapy delivery techniques.Methods 22 cases of esophageal cancer patients were selected for the planning comparison study.All plans were done for IMAT and VMAT treatment plans on Oncentra 4.1 treatment planning system,prescription dose of 2 Gy in total 30 fractions.Planning objectives for PTV were at least 95% reached the prescription dose and V110 no more than 10%.The maximum dose of spinalcord below 45 Gy and double lung dose V20 ≤ 28%,V30 ≤ 18% were constrained.Plans were evaluated based on the ability to meet the dose volume histogram.The dose homogeneity index (HI),radiation conformity index (CI),radiation delivery time,monitor units and γ pass rate were also compared.SPSS 19.0 software paired ttest analysis was carried out on the two sets of data.Results The results showed that the IMAT plans in terms of the PTV's CI (t =3.35,P=0.003),D2(t =-2.27,P=0.034) lung's V30(t =-2.46,P=0.023) were better than that of VMAT group.But the VMAT plans spinal's V40 (t =2.37,P =0.027),lung's V5 (t =2.43,P =0.024) were superior to that of IMAT plans.There were no significant differences between IMAT and VMAT plans in the average dose of PTV,CTV,GTV,heart,spinal cord,double lung and the γpass rate.Conclusion IMAT presents a slight improvement in the OAR sparing in high dose with shorter treatment time when compared to VMAT.While in terms of delivered MU and tissue of low dose irradiated area is higher than that of in VMAT.These two treatment methods all can meet the clinical demand,which should be selected according to the actual situation of the patient.

6.
Chinese Journal of Radiation Oncology ; (6): 265-268, 2014.
Artigo em Chinês | WPRIM | ID: wpr-446685

RESUMO

Objective To investigate the application of the Monte Carlo dose calculation of output factors for electron beams in radiotherapy.Methods The code EGS4/MCTP was used to simulate the head of a medical linear accelerator (Varian 23EX) to calculate the output factors for 6 MeV,9 MeV and 18 MeV electron beams.The source-to-surface distance used was 100 cm.The field sizes ranged from 2 cm × 2 cm to 25 cm × 25 cm.The calculated output factors agreed with the corresponding measured factors which were measured by the IBA Phantom system to within 2%.Then,the output factors of direct articles and indirect articles which were under different energy and various cone-insert combinations were calculated by the code EGS4/MCTP.Results The calculated output factors agreement with the measurements is found to be mostly under the 1% level.The variation of output factors depends on the characteristics of the beams and the modifications that the various cone-insert combinations introduce to these characteristics.Conclusions Monte Carlo dose calculations for electron beams in homogeneous water phantoms have been demonstrated to be accurate under the 1% level in comparison with measurements.The output factors were influenced by energy and cone-insert combinations in complex ways.

7.
The Journal of Practical Medicine ; (24): 2064-2067, 2014.
Artigo em Chinês | WPRIM | ID: wpr-453044

RESUMO

Objective To measure the setup errors and organ movements of patients with esophagus carcinoma during radiotherapy and find a reasonable margin from the clinic target volume (CTV) to the planning target volume (PTV). Methods (1) Set-up veri cation: Forty-two cases of untreated esophageal cancer were enrolled into this study. The physicist firstly made the planning according to the doctor requests and ensured the best distribution at the target. Thereafter, the 0° and 90° digitally reconstructed radiograph (DRR) was transmitted to the iView GT workshop. Meanwhile, two copies of cross-cut electronic portal image (EPI) were required before radiotherapy. Two doctors confirmed the variance of the osteal mark from the EPI and DRR,and output a 3D direction (left to right, superior to inferior, anterior to posterior) of the setup errors through the iView GT software. (2)Breathing motion:Ten cases of untreated esophageal cancer were enrolled into this study.Three distinct breathing levels were deflned: FB (free breathing), EBH (expiration with breath-held) and IBH (inspiration with breath-held). We gave the treatment planning in FB, then by moving the isocenter to EBH and IBH, we recalculated the dose distribution without changing the field angle, shape and weighing (Mus). Displacements were analyzed at four points (anterior, posterior, right lateral and left lateral) and five levels of target (upper, quarter, isocenter, three-quarter and lower). Results (1) The systematic setup errors were -0.23 cm, -0.02 cm and -0.06 cm, and the random errors were 0.44 cm, 0.45 cm and 0.44 cm at the direction of left to right(LR), superior to inferior (SI), anterior to posterior(AP), respectively. (2) The organ movements were 0.3 cm, 0.6cm and 0.3cm at the LR, SI, AP, respectively. Conclusions As an alternative, the root-sum-of-squares of set-up error and organ motion are suggested by σtot=√ (σITV2+σSM2). The CTV to PTV margins are 0.8cm left to right, 0.78cm superior to inferior, 0.5cm anterior to posterior.

8.
Chinese Journal of Radiation Oncology ; (6): 340-342, 2012.
Artigo em Chinês | WPRIM | ID: wpr-427086

RESUMO

ObjectiveTo evaluate correlation factors of cervical lymph nodes metastasis in thoracic esophageal carcinoma.MethodsLocal-regional metastasis of lymph node for 126 cases with esophageal squamous cell cancer after surgery from 2004 to 2009 were reviewed.Risk factors of cervical lymph nodes metastasis were examined by multiple Logistic regression analysis.ResultsIn 126 cases,supraclavicular lymph node metastasis rate was 43.7% (55/126).By logistic regression,none of the primary site,T stage,N stage,histological grade,lymph node metastasis rate,lymph node metastasis degree and number of lymph nodes metastatic field was not the high risk of cervical lymph nodes metastasis.In addition,multivariate analysis found that lymph node metastasis in mediastinum region 1 was high risk factor for lymph node metastasis of region 1 ( x2 =12.14,9.27,P =0.000,0.002),lymph node metastasis in region Ⅲ and region 2 were high risk factors for lymph node metastasis of region Ⅱa ( x2 =14.56,8.27,8.02,3.93,P =0.000,0.004,0.005,0.047 ).ConclusionMediastinal para-recurrent nerve lymph node metastasis is a significant predictor for cervical lymph nodes metastasis.

9.
Chinese Journal of Radiological Medicine and Protection ; (12): 294-296, 2012.
Artigo em Chinês | WPRIM | ID: wpr-427030

RESUMO

Objective To study the relationship between parameter settings in the intensity-modulated radiation therapy (IMRT) planning in order to explore the effect of parameters on absolute dose verification.Methods Forty-three esophageal carcinoma cases were optimized with Pinnacle 7.6c by experienced physicist using appropriate optimization parameters and dose constraints with a number of iterations to meet the clinical acceptance criteria.The plans were copied to water-phantem,0.13 cc ion Farmer chamber and DOSE1 dosimeter was used to measure the absolute dose.The statistical data of the parameters of beams for the 43 cases were collected,and the relationships among them were analyzed.The statistical data of the dosimetry error were collected,and comparative analysis was made for the relation between the parameters of beams and ion chamber absolute dose verification results.Results The parameters of beams were correlated among each other.Obvious affiliation existed between the dose accuracy and parameter settings.When the beam segment number of IMRT plan was more than 80,the dose deviation would be greater than 3% ; however,if the beam segment number was less than 80,the dose deviation was smaller than 3%.When the beam segment number was more than 100,part of the dose deviation of this plan was greater than 4%.On the contrary,if the beam segment number was less than 100,the dose deviation was smaller than 4% definitely.Conclusions In order to decrease the absolute dose verification error,less beam angles and less beam segments are needed and the beam segment number should be controlled within the range of 80.

10.
Chinese Journal of Radiation Oncology ; (6): 414-416, 2011.
Artigo em Chinês | WPRIM | ID: wpr-421283

RESUMO

ObjectiveTo measure the setup errors with infrared marker-based positioning system (IM-BPS) and electronic portal imaging device (EPID) for patients with esophageal carcinoma and lung cancer and investigate the accuracy and practicality of IM-BPS. MethodsFrom January 2007 to January 2008, 40 patients with esophageal carcinoma and 27 patients with lung cancer received three-dimensional conformal radiotherapy or intensity-modulated radiotherapy, setup errors during the treatment were measured with IM-BPS and EPID, and the data of setup errors were compared with paired t-test and agreement with x2-test. ResultsIt takes 10 - 12 mins to complete the validating for each patient by EPID) system, while IMBPS system only needs 2 -5 mins. The mean setup errors along x, y and z-axis for patients with esophageal carcinoma measured by IM-BPS and EPID were 3.49 mm, 3. 19 mm, 3.31 mm and 4. 03 mm, 3.41 mm, 3.43 mm, respectively. For the patients with lung cancer, the setup errors were 4. 23 mm, 3.51 mm, 3. 39mm and 4. 85 mm, 3. 53 mm, 3.74 mm, respectively. The difference of setup errors meanured by the two systems was within 1 mm for 65% esophageal carcinoma patients ( x2 =51.09, P =0. 000), and 55% lung cancer patients ( x2 =53. 35, P =0. 000).Conclusions The measurement results of setup errors for patients with esophageal carcinoma and lung cancer show that IM-BPS is mostly better than EPID. Though validating for patients can be measured accurately and be well quality controlled, IM-BPS is used easily because of macroscopic, homely,spare time and real-time monitoring.

11.
Chinese Journal of Radiation Oncology ; (6): 222-225, 2011.
Artigo em Chinês | WPRIM | ID: wpr-415535

RESUMO

Objective With the Monte Carlo method to recaleulate the IMRT dose distributions from four TPS to provide a platform for independent comparison and evaluation of the plan quality.These results wiU help make a clinical decision as which TPS will be used for prostate IMRT planning.Methods Eleven prostate cancer cases were planned with the Corvus,Xio,Pinnacle and Eclipse TPS.The plans were recalculated bv Monte Cado using leaf sequences and MUs for individual plans.Dose-volume-histograms and isodose distributions were compared.Other quantities such as Dmin(the minimum dose received by 99% of CTV/PTV),Dmax(the maximum dose received by 1%of CTV/PTV),V110%,V105%,V95%(the volume of CTV/PTV receiving 110%,105%.95% of the prescription dose),the volume of rectum and bladder receiving>65 Gy and>40 Gy,and the volume of femur receiving>50 Gy were evaluated.Total segments and MUs were also compared.Results The Monte Carlo results agreed with the dose distributions from the TPS to within 3%/3 mm.The Xio,Pinnacle and Eclipse plans show less target dose heterogeneity and lower V65 and V40 for the rectum and bladder compared to the Corvus plans.The PTV Dmin is about 2 Gy lower for Xio plans than others while the Corvus plans have slightly lower female head V50(0.03%and 0.58%)than others.The Corvus plans require significantly most segments(187.8)and MUs(1264.7)to deliver and the Pinnacle plans require fewest segments(82.4)and MUs(703.6).Conclusions We have tested an independent Monte Carlo dose catculation system for dose reconstruction and plan evaluation.This system provides a platform for the fair comparison and evaluation of treatment plans to facilitate clinical decision making in selecting a TPS and beam delivery system for particular treatment sites.

12.
Chinese Journal of Radiation Oncology ; (6): 64-68, 2011.
Artigo em Chinês | WPRIM | ID: wpr-384848

RESUMO

Objective To compare the results of three dose verification solutions of esophageal carcinoma IMRT plans. Methods Seven esophageal carcinoma cases were planned with Pinnacle 8.0 h.The MATRIXX and Delta4 were chosen as the two-dimensional dosimetry and three-dimensional dosimetry.IMRT plans and Delta4 phantom plans were also recalculated by Monte Carlo. Gamma values were evaluated for MATRIXX and Delta4 with 3 mm/3% gamma criteria. For the comparison of Pinnacle, Delta4 and Monte gamma maps, the dose distribution in central plane, dose profiles and dose-volume histograms were used to evaluate the agreement. Results The gamma maps comparison show that with 3 mm/3% gamma criteria an over 98% pass ratio was obtained by MATRIXX measurement. A 94. 4% gamma pass ratio whicl.contains 4 fields gamma pass ratio lower than 90%, was obtained by Delta4 measurement. A 97.6% and 99. 8% gamma pass ratio was obtained between the Delta4 measurement and Monte Carlo simulation with 2 mm/2% and 3 mm/3% gamma criteria. The dose distribution in central plane and dose profiles from Pinnacle calculation were almost in agreement with both the Monte Carlo simulation and Delta4 measurement. The DVH plot have slightly differences between Pinnacle and Delta4 measurement as well as Pinnacle and Monte Carlo simulation, but have excellent agreement between Delta4 measurement and Monte Carlo simulation. Conclusions It was shown that all the three methods can be used very efficiently to verify esophageal carcinoma IMRT delivery, Delta4 and Monte Carlo simulation no data missed. The primary advantage of Delta4 is the fact it can measure true 3D dosimetry while Monte Carlo can simulate in patients CT images but not in phantom.

13.
Chinese Journal of Radiological Medicine and Protection ; (12): 295-298, 2010.
Artigo em Chinês | WPRIM | ID: wpr-389254

RESUMO

Objective To evaluate the respiration-induced target volume motion in 3D-CRT for mid-thoracic esophageal carcinoma in order to guide the radiation oncologist to choose the expansion marginfor ITV.Methods Ten patients with mid-thoracic esophageal carcinoma were scanned by multi-spiral CTsimulator respectively in free breathing(FB),breath.hold after normal inspiration and expiration(IBH and EBH)with the same scanning range.Then the CT images of three series were transfefred to the treatmentplanning system.The target volume was outlined following the same standard.The motion of the centerpoint of GTV,the center point of each slice of GTV and the edge of the GTV in selected slice weremeasured respectively to obtain the comprehensive value of GTV motion。in order to find the appropriate IMvalue according to the 95%confidence interval of the GTV motion.Results①The GTV motion betweenIBH and EBH was(0.19±0.16)cm in the left.right direction,(0.54±0.19)cm in the cranial andcaudal irection.and(0.16±0.14)cm in anterior.posterior directions for the center of GTV,.For thecenter point of each slice of GTV.they ere(0.19±0.15)cm,(0.54±0.16)cm,(0.16±0.13)cm in three directions above.respectively.For the edge of the GTV in selected slice.they were(0.26±0.19)cm,(0.54±0.18)cm,(0.24±0.19)cm,respectively.The comprehensive value of GTV motion between IBH and EBH was(0.23±0.17)cm,(0.54±0.17)cm,(0.21±0.17)cm.respectively.The 95%confidence interval was 0.21-0.25 cm.0.53-0.56 cm and 0.19-0.22 cm in three directions.②The direction of GTV motion:No motion was noticed in 8.2%.while 73.3%to the right side and 18.5%to the left side in the left-right direction when IBH were compared with EBH.100%were moved to caudal in the the cranial and caudal direction[(0.54±0.17)cm].In the anterior-posterior direction,no motion was noticed in 8.2%,while 16.6%to the posterior and 75.2%to the anterior when IBH were compared with EBH.③The GTV motion was correlated with the vafiance of 1ung volumes in IBH-EBH(r=0.683,P=0.032)and not with GTV volume and length.Conclusions Respiration can induce target volume motion in 3 DCRT for mid-thoracic esophageal carcinoma.Compared to EBH.the GTV tends to move to the caudal,the anterior and the ight side in IBH.

14.
Chinese Journal of Radiation Oncology ; (6): 270-273, 2009.
Artigo em Chinês | WPRIM | ID: wpr-394074

RESUMO

Objective To measure the setup errors of patients with esophageal carcinoma during the treatment of three dimensional conformal radiotherapy (3DCRT), and to analyze the impact of setup errors on dose distribution of GTV,CTV and normal tissues around. Methods Forty-two patients with esophageal cancer treated by 3DCRT were included. The setup errors of each patient were measured once a week for 6 times by electronic portal imaging device (EPID). The setup errors were integrated into the treatment plan-ning system by moving the isocenter. Then the dose distribution of GTV, CTV and normal tissues were recal-culated. Results The systematic setup errors of the 42 patients were - 2.31 mm, - 0.55 mm and - 0.16 mm, and the random errors were 4.42 mm, 4.35 mm and 4.48 mm in the directions of lef-fight, anterior-posterior,and superior-inferior, respectively. The dose covered 95% GTV( D95 ) was reduced by 32 cGy and by 88 cGy for CTV D95. The lung V20 in the original plan and the integrated plan was 22.49% and 22.02%, respectively. The average dose of the heart in the two plans was 2077.62 cGy and 2036.23 cGy, respectively. In the original plan, no patient had maximum dose of spinal cord over 4500 cGy; While in the intergrated plan there were 18 patients had the spinal cord dose more than 4500 cGy, with a maximum dose of 5503.90 cGy. Conclusions The setup errors cause significant dose reduction of GTV and CTV, but not of the lung and heart . The maximum dose of the spinal cord may exceed 4500 cGy due to the setup errors.

15.
Chinese Journal of Radiation Oncology ; (6): 93-96, 2008.
Artigo em Chinês | WPRIM | ID: wpr-402039

RESUMO

Objective To evaluate the variance and the concordance between the tumor length measured by CT scans and that measured by surgical specimens in esophageal carcinoma. Methods Fiftytwo surgical specimens of the esophageal carcinoma were made into pathological giant section.The shrinkage ratio of tumor was calculated by comparing the length of the specimen fixed by formalin for 24 h and that measured during the operation.One hundred and thirty-seven patients with esophageal carcinoma underwent spiral CT scan before the surgery,and the length of the gross tumor volume was obtained.After the tumor length of the fixed specimen had been measured,the real tumor length in situ was calculated using the shrinkage ratio.Then the variance and the concordance between the tumor length in CT scans and that in situ were compared.Results The mean shrinkage ratio was 90%±10%.The mean tumor length in CT scans was longer than that in situ(5.8 am±2.4 cm vs 4.1 cm±1.8 cm,P=9.68,P=0.000).The concordance of the length measured by the two methods was 40.9%(56/137). Conclusions A certain variance existed between the tumor length in CT images and that computed from surgical specimen in esophageal carcinoma.The results of esophagography and endoscopy should also be referred to delineate the gross tumor volume of esophageal carcinoma.

16.
Chinese Journal of Radiation Oncology ; (6): 275-279, 2008.
Artigo em Chinês | WPRIM | ID: wpr-400103

RESUMO

Objective To evaluate the optimized conformal and IMRT plans for the upper esophageal carcinoma. Methods Eight patients with upper esophageal carcinoma underwent CT simulation.GTV was contoured on the CT image,referring the esophagogram and endoscopy simuhaneously,then CTV and PTV were also defined using the same criteria.Different conformal radiotherapy plans consisting of 3 fields(F),4F or 6F,IMRT plans consisting of 3F,4F,5F,7F,9F or 11F,and a simplified IMRT(s-IMRT)plan were designed for these patients.The minimum prescription dose that 95%of PTV volume received was 6000 cGy.Dose distributions of the PTV and OARs in different 3 DCRT and IMRT plans were compared and the optimized plans for the upper esophageal carcinoma were then recommended. Resuits Dose and volume parameters of PTV were similar among the 3DCRT plans(P>0.05).4F 3DCRT plan reduced lung V20 as compared to 6F plan(P<0.05),and mean lung dose(MLD)of 3F and 6F 3DCRT plans were higher than that of4F plan(P<0.05).PTV D100 of 3F IMRT plan was lower than that of 9F and 11F plans(P<0.05).IV of 4F IMRT plan was larger than that of 9F and 11F IMRT plans(P<0.05).PTV dose and volume parameters of the 9F IMRT and 1 1 F IMRT were similar comparing with 5F.7F and s-IMRT plans,and OARs dose was also similar among IMRT plans(P>0.05).PTV CI,D100,D95,V100 and V95 of the 4F 3DCRT plan were all lower than those of 5F,7F and s-IMRT plans(P<0.05).5F,7F and s-IMRT plans reduced lung V20 as compared to 4F 3DCRT plan(P<0.05).Conclusions For the upper esophageal carcinoma.4F 3DCRT plan is recommended among the 3DCRT plans.5F.7F and s-IMRT plans are recommended among the IMRT plans,which are superior than 4F 3 DCRT plan.