1.
Chinese Journal of Medical Instrumentation ; (6): 79-83, 2018.
Artigo em Chinês | WPRIM | ID: wpr-774504

RESUMO

This paper realized an electromagnetic tracking system based on electrically-controlled rotating magnetic field. A tracking system using the digital signal processor (DSP) as the control processing device was developed, including a controllable constant current source module, a magnetic field source module, a three-axis magnetic sensor and ADC interface circuit. The experimental results verified that each time the system could be stable positioning, average error of position was 0.282 cm, the average error of orientation was 0.696o, the positioning time was 1.572 s. Through calibration and further improvement of the hardware circuit, the performance of the system is expected to further improve.


Assuntos
Calibragem , Fenômenos Eletromagnéticos , Desenho de Equipamento , Campos Magnéticos
2.
Chinese Journal of Medical Instrumentation ; (6): 119-122, 2011.
Artigo em Chinês | WPRIM | ID: wpr-330503

RESUMO

Electromagnetic tracking is a method to track the position and space attitude of objects utilizing electromagnetic field. In this paper, the main methods during the development of Electromagnetic tracking are summarized and classified according to the magnetic field generation method, the number of magnetic sources and sensors used, the configuration and geometry of them. Tracking algorithm and calibration methods are also discussed. The critical issues during the development of electromagnetic tracking are analyzed, with the hope of helping the further research and application of electromagnetic tracking.


Assuntos
Algoritmos , Campos Eletromagnéticos , Imagens de Fantasmas
3.
Chinese Journal of Medical Instrumentation ; (6): 82-85, 2010.
Artigo em Chinês | WPRIM | ID: wpr-281158

RESUMO

Electrophysiological stimulator is widely used in study of biological electrical activities. This electrophysiological stimulator is capable of outputting both biphasic and monophasic waveforms with amplitudes within 0V and 30V. The sequence of the biphasic waveforms is alterable and their widths and interval can be respectively arbitrarily modified by the operator. The machine will inform the operator as soon as the charge completes through the indicator and buzzer. The safety of experimental objects is guaranteed by float ground thanks to battery power supply.


Assuntos
Cardioversão Elétrica , Terapia por Estimulação Elétrica , Fenômenos Eletrofisiológicos , Desenho de Equipamento
4.
Journal of Biomedical Engineering ; (6): 1101-1105, 2009.
Artigo em Chinês | WPRIM | ID: wpr-244683

RESUMO

In order to control real-time sampling and achieve smooth scroll wave in the epicardial mapping system, which has 128 channels and a sampling rate of 2kHz/channel, we have designed a user interface using Direct-Draw in cooperation with multiple-thread technology and extracting method. This method has proven to be feasible in animal experiment.


Assuntos
Animais , Algoritmos , Inteligência Artificial , Mapeamento Potencial de Superfície Corporal , Métodos , Técnicas Eletrofisiológicas Cardíacas , Métodos , Pericárdio , Fisiologia , Processamento de Sinais Assistido por Computador , Software
5.
Journal of Biomedical Engineering ; (6): 934-949, 2008.
Artigo em Chinês | WPRIM | ID: wpr-342711

RESUMO

It is important for cardiac therapy devices such as the automated external defibrillator to discriminate different cardiac disorders based on Electrocardiogram analysis. A phase space analysis based algorithm is proposed to detect cardiac arrhythmias effectively. Firstly, the phase space of the signal is reconstructed. Then from the viewpoint of geometry and information theory, the distribution entropy of the point density in the two-dimensional reconstructed phase space is calculated as the features in the further classification. Finally the nearest-neighbour method based on Mahalanobis distance is used to classify the sinus rhythm (SR), supraventricular tachyarrhythmia (SVTA), atrial flutter (AFL) and atrial fibrillation (AF). To evaluate the sensitivity, specificity and accuracy of this proposed method in the cardiac arrhythmias classification, the MIT-BIH arrhythmias database and the canine endocardial database are studied respectively. Experiment results demonstrate that the proposed method can detect SR, SVTA, AFL and AF signals rapidly and accurately with the simple computation. It promises to find application in automated devices for cardiac arrhythmias therapy.


Assuntos
Animais , Cães , Humanos , Algoritmos , Arritmias Cardíacas , Diagnóstico , Eletrocardiografia , Métodos , Entropia , Processamento de Sinais Assistido por Computador
6.
Journal of Biomedical Engineering ; (6): 678-681, 2007.
Artigo em Chinês | WPRIM | ID: wpr-346095

RESUMO

Atrial fibrillation (AF) is a complex and dangerous arrhythmia. The treatment method is still unefficient because of its unknown mechanism. The purpose of our research is to detect the electrical activity on the atria surface and therefore find the optimal technique to characterize AF for clinical application. All kinds of maps are presented clearly and the activity of sinus or AF rhythm can be seen quite differently. The active isopotential map can display the dynamic electrical conduction of the atrium as a movie. Sequentially the vectorgraph shows the direction of depolarization at every moment. Finally statistical results are also very useful for analysis on AF. Statistics of exciting frequency and correlation area show great difference in various channels during AF. "Source" or "sink" may be estimated by interval variance statistics. This study demonstrates the flexibility of the system in AF research. The statistical results can also be adopted to clearly express the characteristics of AF.


Assuntos
Animais , Cães , Fibrilação Atrial , Diagnóstico , Mapeamento Potencial de Superfície Corporal , Métodos , Eletrocardiografia Ambulatorial , Eletrodiagnóstico , Métodos , Pericárdio , Suínos
7.
Space Medicine & Medical Engineering ; (6)2006.
Artigo em Chinês | WPRIM | ID: wpr-579980

RESUMO

Objective To explore a method for real-time pretreatment and character extraction of epicardial signals and promote the research on the electrophysiological mechanism of atrial fibrillation (AF).Methods Firstly,an analysis was made to get the properties of epicardial signals. Then,a method based on template matching was used to extract atrial activities from epicardial signals. At last,the feature points of atrial activities could be recognized.Results The correctness of recognizing feature points of sinus rhythm and AF were 99.7% and 97.0% respectively. Furthermore,only 1~2 s were cost to compute a 10-second data record with this method.Conclusion The proposed method can extract crucial information about atrium depolarization from epicardial signals and is adequate for online analysis.

8.
Space Medicine & Medical Engineering ; (6)2006.
Artigo em Chinês | WPRIM | ID: wpr-575641

RESUMO

Objective To explore the mechanism underlying the superiority of the biphasic waveform to monophasic waveform in defibrillation.Method The Luo-Rudy model was adjusted so that it could be used to study defibrillation.Based on the adjusted model the effects of different defibrillation waveforms on cell action potential duration(APD) were studied.Result Biphasic electrical field pulse extended the APD longer than that with monophasic one.Moreover,biphasic waveforms with different strengths could prolong the APD almost equally,while monophasic pulses with different strengths showed different ability to prolong the APD and the spatial distribution of the APD became dispersed.It was also found that the strength of electrical fields pulse contributed much to the change of APD while the duration showed little effect.Conclusion The clinical superiority of biphasic pulses to monophasic pulses in defibrillation is resulted from its ability to prolong the time course of the APD and more importantly,it causes even spatial distribution of the APD.

9.
Space Medicine & Medical Engineering ; (6)2006.
Artigo em Chinês | WPRIM | ID: wpr-575049

RESUMO

Objective To find a method for real-time measurement of epicardial electrical activity suitable for clinical application.Method Combined unipolar and bipolar mapping technique for recording epicardial electrical activity was applied to detect the propagation of depolarization wave over the epicardium.Epicardial signals from 4 pigs were sampled simultaneously during sinus rhythm or atrial fibrillation(AF).Result Active isopotential map showing the spread of excitation on epicardial surface was demonstrated and correlation analysis data were obtained.The difference in correlation coefficients between adjacent sites was evident during sinus rhythm(above 0.8) and AF(about(0.5).) Conclusion The result shows that combined unipolar and bipolar technique improves the electrode efficiency and the precision in epicardial mapping.Distribution of depolarization wave or the reentry pathway during complex arrhythmia may be revealed by correlation analysis.

10.
Space Medicine & Medical Engineering ; (6): 319-323, 2006.
Artigo em Chinês | WPRIM | ID: wpr-408706

RESUMO

Objective To study the complex restitution relation between the present action potential duration (APD) and its previous diastole interval (DI) and APD. Method The Luo-Rudy model was paced with different protocols to draw the coordinate curves between the present APD and its first previous DI. These curves were fit with the artificial neural network (ANN). Result Different pacing protocols caused different coordinate curves, and there was no one-to-one relation between pre-sent APD and its first previous DI. ANN fits these curves satisfactorily. Conclusion There is a complex relation between the present APD and the APDs and Dis of the first three previous beats. This relation can be modeled accurately with ANN.

11.
Chinese Journal of Medical Physics ; (6): 205-208,210, 2000.
Artigo em Chinês | WPRIM | ID: wpr-604985

RESUMO

This Paper brings forward a new technology of EEG Telemetry. Using two FDM channels, the signals can be transmitted through public telephone lines: the EEG signals are transmitted by TDM technology in one channel; the parametes are transmitted to the receiver for identification of data or synchronization in the other channel synchronously. This technology can satisfy almost any routine clinic needs, and also the quahty of transmission is nearly perfect: the distortion is little; distinct noise pollution and shift of base-line do not exist, which is valuable in medical application.