Chinese Medical Equipment Journal ; (6): 86-90, 2017.
Artigo em Chinês | WPRIM | ID: wpr-662470

RESUMO

Objective To analyze the factors affecting the cleanliness level and infection control in the clean area for pharmacy intravenous admixture service (PIVAS) based on continuous monitoring.Methods The cleanliness indexes such as suspended particle and settling bacteria,infection control indexes such as the hygiene of object surface and hand as well as the noise in the clean area for PIVAS from 2013 to 2016 were monitored continuously according to GB 50457-2008 Clean factory building design specifications of medical industry and Intravenous admixture quality control specification.Results All the indexes accorded with the requirements for cleanliness and infection control except some odd cases unqualified in hand hygiene.Suspended particles increased as the time went by,and decreased along with noise after replacing high-performance filter.Conclusion It's of great significance to qualify the clean area of PIVAS to maintain air conditioning purification system periodically,implement anti-infection measure strictly and standardize continuous monitoring and evaluation.

2.
Chinese Medical Equipment Journal ; (6): 86-90, 2017.
Artigo em Chinês | WPRIM | ID: wpr-660106

RESUMO

Objective To analyze the factors affecting the cleanliness level and infection control in the clean area for pharmacy intravenous admixture service (PIVAS) based on continuous monitoring.Methods The cleanliness indexes such as suspended particle and settling bacteria,infection control indexes such as the hygiene of object surface and hand as well as the noise in the clean area for PIVAS from 2013 to 2016 were monitored continuously according to GB 50457-2008 Clean factory building design specifications of medical industry and Intravenous admixture quality control specification.Results All the indexes accorded with the requirements for cleanliness and infection control except some odd cases unqualified in hand hygiene.Suspended particles increased as the time went by,and decreased along with noise after replacing high-performance filter.Conclusion It's of great significance to qualify the clean area of PIVAS to maintain air conditioning purification system periodically,implement anti-infection measure strictly and standardize continuous monitoring and evaluation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA