Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Adicionar filtros








Intervalo de ano
1.
Chinese Journal of Tissue Engineering Research ; (53): 4975-4982, 2017.
Artigo em Chinês | WPRIM | ID: wpr-666401

RESUMO

BACKGROUND: A Lenke3 type adult idiopathic scoliosis finite element model was established successfully using Mimics software. However, whether the model fits the actual conditions of individualized patients still requires a further revision and validation.OBJECTIVE: To modify and validate the Lenke3 type adult idiopathic scoliosis finite element model by finite element analysis software.METHODS: Based on the characteristics of Lenke3 adult idiopathic scoliosis model, the three-factor and three-level orthogonal experiment was used to optimize the finite element model, making it more close to the actual one. The vertebrae at T1-T4, T5-T8 and L6-S1 levels (sacral lumbarization) were loaded to simulate left and right lateral flexion,as well as extension and flexion, and the range of motion when left and right rotation were compared with Busscher and Yamamoto experiments in vitro.RESULTS AND CONCLUSION: (1) According to the orthogonal experiment, the mean difference and range of each factor and each level were calculated, and finally A1B2C3 combination was the optimal one that can make the model largely consistent with the real situation. The difference in Cobb angles between the clinical lateral flexion test and the parameter pre-modified model simulation was 54.44°, which was decreased to 2.11° after modification. Moreover, the maximum difference in each scoliosis Cobb angle of the modified model was 4.29°. (2) The simulation results of the modified model when compared with the X-ray images when left and right lateral flexion, the two data obeyed normal distribution, so the paired t test was used: left lateral flexion, P =0.082 (P > 0.05); right lateral flexion, P=0.421 (P > 0.05);supine position, P=0.160 (P > 0.05). (3) The range of motion at T1-T4 segments was as followings: left flexion, 3.25°;right flexion, 3.32°; anteflexion 2.52°; extension, 2.89°; left rotation, 3.73°; right rotation 3.76°; the range of motion at T5-T8 segments: left flexion, 1.39°; right flexion, 1.43°; anteflexion 1.35°; extension, 1.34°; left rotation 2.09°; right rotation 2.11°; the range of motion at L6/S1: left flexion: 5.17°; right flexion: 5.19°; anteflexion: 8.92°; extension: 7.35°; left rotation: 1.41°; right rotation: 1.42°. The results were almost consistent with Busscher and Yamamoto experimental results. (4) To conclude, the model is in good agreement with the patient's actual properties after modification. The modified model has good reliability and validity, and provides valid data platform for simulating clinical operation in the future.

2.
Chinese Medical Equipment Journal ; (6): 151-153,156, 2017.
Artigo em Chinês | WPRIM | ID: wpr-662360

RESUMO

Objective To standardize the purchasing procedure of aseptic high-value consumables to benefit the hospital and patient.Methods The present situation of aseptic high-value consumables management was introduced,the purchasing procedure of them was analyzed,and some countermeasures were put forward aiming at the problems in the purchasing procedure.Results Some suggestions were brought out including normalizing the access qualification management and purchase procedure,executing barcode management to improve its tractability,training administrative staffs to promote refined management and completing aseptic high-value consumables management system.Conclusion The purchasing procedure of aseptic high-value consumables can be improved from the aspects of management system,information management,personnel training and etc.

3.
Chinese Medical Equipment Journal ; (6): 151-153,156, 2017.
Artigo em Chinês | WPRIM | ID: wpr-659872

RESUMO

Objective To standardize the purchasing procedure of aseptic high-value consumables to benefit the hospital and patient.Methods The present situation of aseptic high-value consumables management was introduced,the purchasing procedure of them was analyzed,and some countermeasures were put forward aiming at the problems in the purchasing procedure.Results Some suggestions were brought out including normalizing the access qualification management and purchase procedure,executing barcode management to improve its tractability,training administrative staffs to promote refined management and completing aseptic high-value consumables management system.Conclusion The purchasing procedure of aseptic high-value consumables can be improved from the aspects of management system,information management,personnel training and etc.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA