Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Adicionar filtros








Intervalo de ano
1.
Chinese Journal of Blood Transfusion ; (12): 327-334, 2021.
Artigo em Chinês | WPRIM | ID: wpr-1004515

RESUMO

With continuous discovery of tumor immune targets and continuous changes in antibody research and development technology, antibody drugs are becoming more and more widely used in clinical practice. However, some targets are not only expressed on tumor cells, but also on red blood cells. Therefore, the clinical application of antibodies against the corresponding targets may interfere with the detection of blood transfusion compatibility, resulting in difficulty in blood matching or delay of blood transfusion. This consensus summarizes the current solutions for the interference of CD38 monoclonal antibody (CD38 mAb) in transfusion compatibility testing. After analyzing the advantages and disadvantages of different methods, polybrene and sulfhydryl reducing agents [dithiothreitol (DTT) or 2-mercaptoethanol (2-Me)], as a solution for CD38 mAb interference in blood compatibility testing, are recommended for Chinese patients, so as to eliminate blood transfusion interference produce by CD38 mAb and further provide a pre-transfusion workflow for clinicians and technicians in Department of Blood Transfusion.

2.
Braz. j. microbiol ; 49(3): 564-568, July-Sept. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-951797

RESUMO

Abstract The objective of this study was to standardize and validate the dot-blot test for the serological diagnosis of bovine brucellosis, compare the results with those found in the 2-mercaptoethanol (2-ME) and complement fixation test (CF), and estimate the relative sensitivity and specificity of the dot-blot compared to these tests. Fifty bovine blood serum samples were used for the test standardization, and 1315 samples were used for evaluation and comparison between the tests; the results were compared using the Kappa indicator. At the end of standardization, it was established as optimal for the antigen obtained from Brucella abortus B19 after passing through a microorganism rupture process, the blood serum samples diluted at 1:100, and the conjugate at 1:30,000. The comparison of the dot-blot results with 2-ME showed Kappa index of 0.9939, sensitivity of 99.48%, and specificity 99.91%, with CF, Kappa index of 0.8226, sensitivity 100% and specificity 95.32%. Using the combination of the test results 2-ME and CF to establish the true condition of the animal, the dot-blot showed relative sensitivity of 100%, and relative specificity of 99.91%. The evaluated test proved to be effective and reliable, besides being easy to handle and interpret the results.


Assuntos
Animais , Bovinos , Brucella abortus/isolamento & purificação , Brucelose/veterinária , Testes Sorológicos/métodos , Doenças dos Bovinos/diagnóstico , Anticorpos Antibacterianos/sangue , Brucella abortus/imunologia , Brucelose/diagnóstico , Brucelose/microbiologia , Brucelose/sangue , Testes Sorológicos/instrumentação , Doenças dos Bovinos/microbiologia , Doenças dos Bovinos/sangue , Sensibilidade e Especificidade
3.
Journal of Pharmaceutical Analysis ; (6): 269-275, 2015.
Artigo em Chinês | WPRIM | ID: wpr-477579

RESUMO

A sensitive method based on high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been developed for the simultaneous determination of folic acid (FA) and its active metabolite, 5-methyltetrahydrofolic acid (5-M-THF), in human plasma. The analytes were extracted from plasma with methanol solution containing 10 mg/mL of 2-mercaptoethanol and 0.025% (v/v) ammonium hydroxide. FA and 5-M-THF were more stable after the addition of 2-mercaptoethanol and ammonium hydroxide in the sample preparation procedures of this study than they were in the previously published methods. Chromatographic separation was performed on a Hedera ODS-2 column using a gradient elution system of acetonitrile and 1 mM ammonium acetate buffer solution containing 0.6% formic acid as mobile phase. LC-MS/MS was carried out with an ESI ion-source and operated in the multiple reaction monitoring (MRM) mode. The assay was linear over the concentration ranges of 0.249-19.9 ng/mL for FA, and 5.05-50.5 ng/mL for 5-M-THF. The developed LC-MS/MS method offers increased sensitivity for quantification of FA and 5-M-THF in human plasma and was applicable to a pharmacokinetic study of FA and 5-M-THF.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA