Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Chinese Journal of Radiological Medicine and Protection ; (12): 422-427, 2019.
Artigo em Chinês | WPRIM | ID: wpr-754984

RESUMO

Objective To propose a treatment planning optimization algorithm which can make full use of OAR dose distribution prediction meanwhile improving the output planning quality as much as possible.Methods We had reformulated an FMO function under the guidance of dose distribution prediction and also integrated equivalent uniform dose (gEUD) based on the consideration of prediction uncertainty,for providing optimal solution.Performance of the method was evaluated by comparing the optimized IMRT plan quality of 8 cervical cancers in the term of DVH curves,dose distribution and dosimetric endpoints with the original ones.Results The proposed method had a feasible,fast solution.Compared with original plan,its output plan had better plan quality in better dose homogeneity,less hot spot and further dose sparing for OARs.V30,V45 of rectum was decreased by (6.60±3.53)% and (17.03±7.44)%,respectively,with the statistically significant difference (t=-4.954,-6.055,P<0.05).V30,V45 of bladder was decreased by (14.74 ± 5.61) % and (14.99 ± 4.53) %,respectively,with the statistically significant difference (t=-6.945,-8.759,P<0.05).Conclusions We have successfully developed a predicted dose distribution and equivalent uniform dose-based planning optimization method,which is able to make good use of 3D dose prediction and ensure the output plan quality for intensity modulated radiation therapy.

2.
Korean Journal of Medical Physics ; : 54-61, 2012.
Artigo em Coreano | WPRIM | ID: wpr-81822

RESUMO

A polymer gel dosimeter was fabricated. A 3-dimensional dosimetry experiment was performed in the small field of the photon of the cyberknife. The dosimeter was installed in a head and neck phantom. It was manufactured from the acrylic and it was used in dosimetry. By using the head and neck CT protocol of the CyberKnife system, CT images of the head and neck phantom were obtained and delivered to the treatment planning system. The irradiation to the dosimeter in the treatment planning was performed, and then, the image was obtained by using 3.0T magnetic resonance imaging (MRI) after 24 hours. The dose distribution of the phantom was analyzed by using MATLAB. The results of this measurement were compared to the results of calculation in the treatment planning. In the isodose curve on the axial direction, the dose distribution coincided with the high dose area, 0.76mm difference on 80%, rather than the low dose area, 1.29 mm difference on 40%. In this research, the fact that the polymer gel dosimeter and MRI can be applied for analyzing a small field in a 3 dimensional dosimetry was confirmed. Moreover, the feasibility of using these for the therapeutic radiation quality control was also confirmed.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica , Citarabina , Cabeça , Imageamento por Ressonância Magnética , Pescoço , Polímeros , Controle de Qualidade , Tioguanina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA