Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Adicionar filtros








Intervalo de ano
1.
Chinese Journal of Orthopaedic Trauma ; (12): 470-477, 2023.
Artigo em Chinês | WPRIM | ID: wpr-992735

RESUMO

Objective:To investigate the early clinical effectiveness of using customized 3D printed acetabular augment to repair large acetabular bone defects in delayed total hip arthroplasty after failed treatment of acetabular fractures.Methods:A retrospective study was conducted to analyze the 6 patients who had undergone 3D printed acetabular augment to reconstruct acetabular bone defects in delayed total hip replacement from July 2021 to January 2023 after failed treatment of acetabular fractures. They were all males, with an age of (51.3±15.0) years. Paprosky classification: 2 cases of type ⅡB, 1 case of type ⅡC, and 3 cases of type ⅢA. Recorded were surgical time, intraoperative bleeding, hospitalization time, and visual analogue scale (VAS), and modified Merle d'Aubigné & Postel score, Harris hip score, and leg length discrepancy at the last follow-up.Results:For the 6 patients, the mean surgical time was (222.5±46.9) min, the mean intraoperative bleeding 1,100 (1,000, 2,625) mL, the mean hospitalization time (9.0±4.5) d, and the mean follow-up time (11.8±7.9) months. At the last follow-up, the VAS [(2.5±1.0) points] significantly decreased compared with the preoperative value [(6.2±0.8) points], the modified Merle d'Aubigné & Postel score [(13.2±2.1) points] and Harris hip score [(67.8±15.3) points] significantly increased compared with the preoperative values [(6.7±0.8) and (34.2±8.4) points], the vertical position of center of rotation [(22.5±5.2) mm] and the horizontal position of center of rotation [(40.7±2.6) mm] were significantly reduced compared with the preoperative values [(38.1±14.2) and (53.1±10.0) mm] ( P<0.05). At the last follow-up, the leg length discrepancy was (6.2±3.6) mm, showing no statistically significant difference from the preoperative value [(18.7±1.7) mm] ( P>0.05). At the last follow-up, no clear line at the cup-bone or augment-bone interface, or no possible prosthetic loosening or displacement was observed on the X-ray films. Conclusion:In delayed total hip arthroplasty after failed treatment of acetabular fractures, the customized 3D printed augment for repair of large bone defects in the acetabulum can reconstruct the normal rotation center of the hip joint, provide reliable stability for the cup prosthesis, and enable patients to obtain significant improvements in hip function.

2.
Chinese Journal of Orthopaedic Trauma ; (12): 1024-1029, 2022.
Artigo em Chinês | WPRIM | ID: wpr-992662

RESUMO

Objective:To explore the safety and efficacy of the minimally invasive treatment of unstable pelvic fractures with the blunt head technique of Kirschner wire and 3D-printed external template technique.Methods:A retrospective study was conducted of the clinical data of 21 patients with unstable pelvic fracture who had undergone minimally invasive treatment at Department of Orthopaedics, Union Hospital from May 2016 to July 2018 using 3D-printed external templates and the blunt head technique of Kirschner wire. There were 7 males and 14 females with an age of 43.6 years (from 19 to 65 years). According to the Tile classification, there were 3 cases of B1, 7 ones of B2, 6 ones of C1 and 5 ones of C2. The intraoperative fluoroscopy, operation time, postoperative fracture reduction and functional recovery of the pelvis at the last follow-up were recorded.Results:The 21 patients were followed up for an average of 16.3 months (from 12 to 24 months). A total of 33 wires were inserted in the 21 patients, including 15 S 1 ones and 18 S 2 ones. The intraoperative fluoroscopy ranged from 13 to 27 times, averaging 21.8 times. The operation time ranged from 65 to 130 min, averaging 88.6 min. The anterior subcutaneous internal fixation was used to fix the anterior ring in 9 patients. No vascular injury occurred during the operation. By the Matta criteria, the postoperative fracture reduction was assessed as excellent in 14 cases, good in 5, and fair in 2, giving an excellent to good rate of 90.5% (19/21). By the Majeed scoring system, the pelvic function at the last follow-up was assessed as excellent in 10 cases, good in 8, and fair in 3, giving an excellent to good rate of 85.7% (18/21). Lateral femoral cutaneous nerve injury occurred in 2 patients but was recovered by the 3-month follow-up. No other complications were follwed up. Conclusion:The minimally invasive treatment of unstable pelvic fractures with the blunt head technique of Kirschner wire assissted by 3D-printed external templates is safe and effective, showing advatages of reduced fluoroscopic frequency and operation time.

3.
Chinese Journal of Orthopaedic Trauma ; (12): 516-523, 2019.
Artigo em Chinês | WPRIM | ID: wpr-754754

RESUMO

Objective To explore the efficacy of the anterior lateral-rectus approach combined with preoperative simulation assisted by 3D printing for treatment of acetabular fractures in the elderly.Methods A total of 52 elderly patients with acetabular fracture were admitted to Department of Orthopaedics and Trauma,The Third Affiliated Hospital to Southern Medical University from January 2014 to December 2017.They were 36 males and 16 females,with an average age of 71.6 years (from 65 to 88 years).According to the Judet-Letournel classification,there were 5 anterior column fractures,6 transverse fractures,18 anterior and posterior hemi-transverse fractures,and 23 both-column fractures.For all cases a preoperative surgical simulation was implemented based on their 3D-printed acetabular models.A pre-bent reconstruction plate or a custom acetabular aliform plate was placed to fixate the fracture after reduction via the anterior lateral-rectus approach.The reduction quality,healing time,function of affected hip and complications were recorded.Results The operation time for this cohort ranged from 85 to 138 min (average,102 min);the intraoperative bleeding ranged from 280 to 750 mL(average,520 mL).Perioperatively,implant failure,wound infection or symptomatic lower extremity phlebothrombosis was observed in none of the patients.According to the Matta radiological evaluation,the postoperative reduction was rated as excellent in 40 cases,as good in 7 and as poor in 5 (an excellent and good rate of 90.4%).All cases were followed up for 6 to 18 (mean,10.6 months).All the acetabular fractures united after 8 to 20 weeks (average,12 weeks).According to the modified Merle d'Aubigne-Postal scoring at the final follow-up,the function of affected hip was categorized as excellent in 29 cases,as good in 12 and as fair in 11 (an excellent and good rate of 78.8%).Walking pain was experienced by 5 patients 6 months after operation,diagnosed by imaging examination as traumatic arthritis of the hip joint.Follow-ups observed no such complications as screw loosening or heterotopic ossification.Conclusion In the treatment of acetabular fractures in the elderly,the anterior lateral-rectus approach combined with preoperative simulation assisted by 3D printing can achieve effective reduction and fixation,decrease intraoperative hemorrhage,shorten operation time and reduce such complications as screw loosening caused by osteoporosis.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA