Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Adicionar filtros








Intervalo de ano
1.
Chinese Journal of Endocrine Surgery ; (6): 274-277, 2018.
Artigo em Chinês | WPRIM | ID: wpr-695563

RESUMO

Objective To investigate the preoperative localizaion diagnosis and surgical strategies of primary hyperparathyroidism (pHPT).Methods The clinical data of pHPT patients who underwent initial parathyroid surgery at the Peking Union Medical College Hospital from Jan.2009 to Apr.2017 were retrospectively analyzed to explore preoperative localization and surgical options.Results There were a total of 902 surgical cases included in the study with 674 women and 228 men.All had preoperative parathyroid ultrasonography (US) (sensitivity 97.18%,positive predictive value (PPV) 98.40%) and 99Tcm-sestamibi (MIBI) scan (sensitivity 94.24%,PPV 98.00%).The combination of US and MIBI scan had a sensitivity of 92.39% and PPV of 97.37%.MIBI scan showed negative results in 51 cases.We found that male patients with cystic lesions were more likely related to negative MIBI scan (P<0.05).Among 89 patients with negative MIBI and/or US,39 received neck CT,17 received positron emission tomography (PET)/CT,and 9 received ultrasound-guided biopsy for further localization.800 patients (88.69%) underwent minimally invasive parathyroid surgery (MIP) with anesthesia of cervical plexus block.656 patients (72.72%) had normal parathyroid hormone (PTH) level on the first post-operative day,140 patients (15.52%) had postoperative hypocalcaemia and 234 patients (25.94%) presented hypocalcaemic symptoms within 3 days after operation,which could be relieved by intravenous calcium or continuous medicine taken by mouth.During the follow-up of the 800 MIP patients,4 had recurrence and one patient was not cured.Conclusions Parathyroid US and MIBI scan are of good value in localizaion diagnosis.Neck CT or PET/CT should be used as supplementary approaches in patients with negative US and/or MIBI scan.MIP with anesthesia of cervical plexus block is simple and feasiable for pHPT cases with accurate localization.

2.
Chinese Journal of Medical Imaging Technology ; (12): 509-513, 2018.
Artigo em Chinês | WPRIM | ID: wpr-706271

RESUMO

Objective To investigate the efficacy of SPECT/CT in detecting parathyroid lesions in chronic kidney disease (CKD) with secondary hyperparathyroidism (sHPT) patients.Methods Within 2 weeks before parathyroidectomy (PTX),52 patients of CKD with sHPT underwent 99Tcm-sestamibi (99Tcm-MIBI) dual-phase planar and delayed SPECT/CT scintigraphy.Taking surgical pathology as the golden standards,the sensitivity,specificity and accuracy of dual-phase planar,SPECT,CT and SPECT/CT were calculated and compared.Results Totally 172 lesions were detected in surgical operation,including 13 parathyroidomas (PM),26 adenomatoid hyperplasias (AH) and 133 diffuse parathyroid hyperplasias (PH).The sensitivity of 99Tcm-MIBI dual-phase planar,SPECT,CT and SPECT/CT was 55.81% (96/172),70.35% (121/172),79.65% (137/172) and 81.40% (140/172),respectively,while the specificity was 92.05%(81/88),90.91% (80/88),76.14% (67/88),93.18% (82/88),the accuracy was 68.08% (177/260),77.31% (201/260),78.46% (204/260) and 85.38% (222/260),respectively.The sensitivity of SPECT/CT was superior to that of SPECT (x9 =17.053,P<0.001) and 99Tcm-MIBI dual-phase planar (x2 =44.000,P<0.001).SPECT/CT was superior to CT (x2 =10.316,P =0.001) for specificity,and superior to CT (x2 =13.136,P<0.001),SPECT (x2 =14.815,P<0.001) or 99Tcm-MIBI dual-phase planar (x2=39.706,P<0.001) for accuracy.Conclusion SPECT/CT fusion imaging is better in localization of parathyroid lesions of CKD with sHPT patients than 99Tcm-MIBI dual-phase planar,SPECT or CT imaging alone.

3.
Chinese Journal of Medical Imaging ; (12): 772-776, 2017.
Artigo em Chinês | WPRIM | ID: wpr-706404

RESUMO

Purpose To evaluate the clinical guiding value of 99Tcm-methoxyisobutylisonitrile gated myocardial perfusion imaging (99Tcm-MIBI G-MPI) in diagnosing the coronary microangiopathy in patients with diabetic mellitus.Materials and Methods Sixty patients with clinical confirmed coronary microvascular angina were selected and assigned into two groups,with 26 patients (with diabetes mellitus) in group A and 34 patients in group B (without diabetes mellitus).The region,extent and range of coronary microangiopathy was detected by 99Tcm-MIBI G-MPI,and the difference of myocardial ischemia between the two groups was statistically analyzed.Results The ratio of abnormal myocardial perfusion in group A was significantly higher than that in group B (96.15% vs.73.53%,x2=5.43,P<0.05);the total number of abnormal coronary branches in group A was significantly larger than that in group B (82.67% vs.62.67%,P<0.05);the total number abnormal perfusion segments in group A was significantly larger than that in group B (P<0.05),and the abnormal perfusion segments number of anterior wall,septum,apical region and inferior wall in group A was significantly larger than that ingroup B (P<0.05);the rate of abnormal perfusion at single coronary supplying region in group A was significantly lower than that in group B (P<0.05).Conclusion 99Tcm-MIBI G-MPI is of great clinical significance for diagnosing coronary microangiopathy and evaluating myocardial ischemia in patients with diabetes mellitus.

4.
Cancer Research and Clinic ; (6): 455-457, 2009.
Artigo em Chinês | WPRIM | ID: wpr-380692

RESUMO

Objective To investigate the clinical value of 99Tcm-MIBI SPECT-CT image fusion technology for diagnosing breast tumor and detecting axiiiary lymph node metastasis. Methods 99Tcm-MiBI breast and axillary lymph node planar and SPECT-CT imaging in 80 female breast tumor patients were done. All patients had pathological examination results after surgery as control. Results SPECT-CT fusion images sensitivity for breast cancer diagnosis, specificity and accuracy rates were 88.2 % (45/51), 93.1% (26/29) and 90 % (71/80). Planar imaging sensitivity, specificity and accuracy rate were 82.4 % (42/51), 79.3 %(23/29) and 81.3 %(65/80). SPECT-CT fusion images were higher than planar imaging (P <0.05). SPECT-CT fusion images sensitivity, specificity and accuracy for detecting axillary lymph node metastasis were 81.8 %(18/22), 89.7 % (26/29) and 86.3 % (44/51). Planar imaging sensitivity, specificity and accuracy were 77.2 % (17/22), 86.2 % (25/29) and 82.4 %(42/51). There was no significant difference between them (P0.05). Conclusion SPECT-CT image fusion technology in the diagnosis of breast cancer is better than planar imaging. SPECT-CT image fusion in detecting axillary lymph node metastasis of breast cancer is similar to planar imaging.

5.
Journal of Applied Clinical Pediatrics ; (24)1986.
Artigo em Chinês | WPRIM | ID: wpr-639029

RESUMO

Objective To discuss the clinical value of 99Tcm-sestamibi(99Tcm-MIBI) myocardial perfusion imaging on detecting myocardial ischemia in children with Kawasaki disease(KD) at convalescence period.Methods Twenty-one children wih KD at convalescence period were divided into 2 groups according to results of echocardiography.Four cases with coronary artery dilation,17 cases without coronary artery dilation.All cases accepted dipyridamole stress myocardial perfusion imaging.These patients who had positive results were given rest myocardial perfusion imaging again next day.Results Among 21 cases,9 cases(42.8%) were positive in perfusion imaging.Four cases with coronary artery dilation showed myocardial ischemia in different degree detected by myocardial perfusion imaging.Among 17 cases without coronary artery dilation,5 cases(29.4%) were positive.Conclusions Compared to echocardiography,99Tcm-MIBI myocardial perfusion imaging can objectively evaluate the location,extent and degree of myocardial ischemia of children with KD.It will be a routine test in observing its phase development.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA