Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Adicionar filtros








Intervalo de ano
1.
Rev. peru. biol. (Impr.) ; 27(1): 43-48, ene.-mar 2020.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1144929

RESUMO

Abstract The various industrial sectors, as well as livestock and agricultural activities, are increasing the production of inputs to meet the demand of the worldwide demographic explosion, making a challenge the clean maintenance of water, soil, and air. Therefore, the search for solutions for a pollutant-free environment without compromising economic development has become extremely important. Thereby, biotechnological studies in order to solve environmental issues have been gaining extensive attention through the coupling of technology procedures to biological systems as sustainable solutions to remediate contaminated areas. In this sense, this review covers topics such as the role of Omics era in microbial environmental biotechnology for pollution control as well as the microbial fuel cell use in energy production. Moreover, phytoremediation and the perspective of applying chemical methods are approached as environmentally friendly tools for the pollutant control to improve remediation processes.


Resumen Los diversos sectores industriales, así como las actividades ganaderas y agrícolas, están aumentando la producción de insumos para satisfacer la demanda de la explosión demográfica mundial, lo cual dificulta el mantenimiento limpio del agua, el suelo y el aire. Por lo tanto, la búsqueda de soluciones para un medio ambiente libre de contaminantes sin comprometer el desarrollo económico se ha vuelto extremadamente importante. De este modo, los estudios biotecnológicos para resolver problemas ambientales han recibido una gran atención a través del acoplamiento de procedimientos tecnológicos a sistemas biológicos como soluciones sostenibles para remediar áreas contaminadas. En este sentido, esta revisión cubre temas como el papel de la era Ómica en la biotecnología ambiental microbiana para el control de la contaminación, así como el uso de celdas de combustible microbianas en la producción de energía. Además, la fitorremediación y la perspectiva de aplicar métodos químicos se abordan como herramientas ecológicas para el control de contaminantes y mejorar los procesos de remediación.

2.
Rev. colomb. quím. (Bogotá) ; 47(2): 36-44, mayo-ago. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-960198

RESUMO

Abstract Reactive Black 5 (RB5) is an azo dye widely used in the textile industry because of its high chemical stability. Since it does not entirely fix on the fabrics, it pollutes water sources. In this work, the decolorization of aqueous solutions with RB5 was performed by heterogeneous photocatalysis with TiO2/UV. The reaction was carried out in an aluminum photoreactor equipped with five lamps. The effect of TiO2 (0.1, 0.175, and 0.25 g L-1), RB5 concentration (50, 75, and 100 mg L-1), and pH (3, 7, and 11) was evaluated for 14 h, using a Box-Behnken experimental statistical design. Complete decolorization of RB5 was obtained at 14 h, employing 0.175 g L-1 TiO2, 50 mg L-1 RB5, and pH 3. A 98.44% of decolorization was achieved in 10 h (0.25 g L-1 of TiO2, 50 mg L-1 of RB5, and pH 7). The highest decolorization percentage of RB5 (99.51%) was obtained at 10 h of exposure to UV light, using 0.5 g L-1 of TiO2, 50 mg L-1 of the dye, and a pH of 3. Cytotoxicity tests on the HepG2 cell line indicated that photocatalytic degradation of RB5 did not generate cytotoxic byproducts.


Resumen El Negro Remazol B (NRB) es un colorante azoico, usado en la industria textil por su estabilidad química. Este tinte no se fija al 100%, ocasionando contaminación en el agua. En este trabajo se evaluó la decoloración de soluciones acuosas con NRB mediante fotocatálisis heterogénea con TiO2/UV. La reacción se realizó en un fotorreactor de aluminio equipado con cinco lámparas. El efecto de la concentración de TiO2 (0,1; 0,175 y 0,25 g L-1), y NRB (50, 75 y 100 mg L-1) y el pH (3, 7 y 11) fue evaluado durante 14 h, tomando un diseño estadístico experimental Box-Behnken. La decoloración completa del NRB se obtuvo después de 14 h (0,175 g L-1 de TiO2, 50 mg L-1 de NRB, y pH 3). Se alcanzó un 98,44% de decoloración después de 10 h (0,25 g L-1 de TiO2, 50 mg L-1 de NRB, y pH 7). Se encontró que el mejor porcentaje de decoloración del NRB (99,51%) se obtuvo a las 10 h de exposición a luz UV, utilizando 0,5 g L-1 de TiO2, 50 mg L-1 del colorante y un pH de 3. Los ensayos de citotoxicidad sobre la línea celular HepG2 indicaron que la degradación fotocatalítica del NRB no generó subproductos citotóxicos.


Resumo O Negro Remazol B (RNB) é um corante azoico usado na indústria têxtil pela sua estabilidade química. O corante não é fixo no tecido em 100%, então contamina as fontes de água. Neste trabalho, avaliou-se a descoloração de soluções aquosas com RNB por meio de fotocatálise heterogênea com TiO2/UV. A reação foi feita no fotoreactor de alumínio com cinco lâmpadas. O efeito da concentração de TiO2 (0,1; 0,175 e 0,25 g L-1), RNB (50, 75 e 100 mg L-1) e pH (3, 7 e 11) foi avaliado durante 14 h utilizando o modelo estatístico Box-Behnken. Ás 14 h, foi atingida a descoloração completa do RNB (pH 3; 0,175 g L-1 de TiO2 e 50 mg L-1 de RNB). Utilizando 0,25 g L-1 de TiO2, 50 mg L-1 de RNB e pH 7, obteve-se descoloração de 98,44% em 10 h. Encontrou-se que a melhor porcentagem de descoloração do RNB (91,51%) foi obtida com 10 h de exposição à luz UV usando 0,5 g L-1 de TiO2, 50 mg L-1 do corante e pH de 3. Adicionalmente, os testes de citotoxicidade na linha celular HepG2 mostraram que a degradação fotocatalítica do RNB não gerou subprodutos citotóxicos.

3.
Eng. sanit. ambient ; Eng. sanit. ambient;22(5): 1017-1026, set.-out. 2017. tab, graf
Artigo em Português | LILACS | ID: biblio-891586

RESUMO

RESUMO A desinfecção adequada de águas cinzas é necessária para garantir a segurança de sua reutilização, principalmente em aplicações com potencial de exposição humana. Diversos processos oxidativos avançados têm sido empregados nos últimos anos para a degradação de contaminantes orgânicos, bem como para desinfecção de águas e efluentes. O objetivo deste trabalho foi testar TiO2 suportado em microtubos para desinfetar águas cinzas por meio da fotocatálise heterogênea, visando ao reúso hídrico em bacia sanitária. A água cinza utilizada nos experimentos foi coletada após passar por um sistema de tratamento composto de um tanque de evapotranspiração seguido de banhado construído de fluxo horizontal. Foram realizados testes em batelada utilizando-se um reator fotoquímico cilíndrico de 1,0 L (volume total do reator), preenchido com pequenos cilindros de vidro do tipo Pyrex com TiO2 suportado. Para os testes de desinfecção, foram utilizados os processos UV, H2O2, UV/TiO2, UV/H2O2 e UV/TiO2/H2O2. Foi possível obter uma camada homogênea de TiO2 depositada nos pequenos tubos de vidro Pyrex, com espessura média de 35,3 µm, capaz de promover um incremento na desinfecção de águas cinzas. Porém, mesmo com um maior poder de desinfecção do TiO2 - se comparado com a fotólise (UV) -, os processos em que se empregou o peróxido de hidrogênio foram bem mais eficientes, tanto na desinfecção (inativação total de coliformes totais, enterococos e Pseudomonas aeruginosa) quanto na remoção de matéria orgânica em termos de demanda química de oxigênio (em torno de 60%). As amostras mantidas em temperatura ambiente e envolvidas por plástico escuro não apresentaram recrescimento bacteriano com 24h de armazenamento após os experimentos, mostrando assim a viabilidade da água cinza tratada em reúso doméstico.


ABSTRACT Proper disinfection of greywater is needed to ensure the safety of its reuse, especially in applications with potential for human exposure. Various advanced oxidation processes have been used in recent years for the degradation of organic contaminants, as well as for disinfection of water and wastewater. The purpose of this study was to test TiO2 supported in microtubes to disinfect greywater by photocatalysis in order to reuse it in sanitary bowl. The greywater used in the experiments was collected after passing through a treatment system consisting of an evapotranspiration tank followed by constructed wetland with horizontal flow. Batch tests were conducted using a cylindrical photochemical reactor of 1.0 L (total volume of the reactor), filled with small glass Pyrex cylinders with supported TiO2. For disinfection tests, the processes UV, H2O2, UV/TiO2, UV/H2O2 and UV/TiO2/H2O2 were used. It was possible to obtain a homogeneous layer of TiO2 deposited in small Pyrex glass tubes with an average thickness of 35.3 µm; this layer was able to promote an increase in the greywater disinfection. However, even with a greater disinfection power of TiO2 compared with photolysis (UV), the processes with hydrogen peroxide was much more efficient in disinfection (total inactivation of total coliforms, enterococci and Pseudomonas aeruginosa) and in the removal of organic matter in terms of chemical oxygen demand (around 60%). Samples stored at a room temperature and wrapped in plastic dark showed no bacterial regrowth after 24 hours of storage after the experiments, thus showing the viability of treated greywater for domestic reuse.

4.
Rev. ciênc. farm. básica apl ; Rev. ciênc. farm. básica apl;35(3)set. 2014.
Artigo em Português | LILACS | ID: lil-737697

RESUMO

The increasing disposal of medicines into the environment has increased concern about the possible environmental impact of such actions, in both the medium and long term. Estrogens have been found in soil, surface water and groundwater. The aim of this study was to assess the ecotoxicity of chemical residues originating from in situ oxidation of 17β estradiol with hydrogen peroxide, a process of chemical remediation which is used to remove these hormones in acetone solution, at various pHs. Analyses were carried out by high resolution gas chromatography and a bioassay in which the single-cell species Euglena gracilis was the test organism. The results were obtained by comparing analyses done before and after the AOP (advanced oxidation process). It was observed that at pH 5.0, with a treatment time of 20 minutes, there was a good yield, but with some change in the behavior of the test organism. With a pH of 7.0, with 20 minutes time, the yield was low but there was no demonstration of ecotoxicological activity...


Com o crescente descarte de medicamentos no meio ambiente, observa-se o aumento da preocupação com o impacto ambiental que tal ação pode acarretar, tanto a médio como em longo prazo. Os estrogênios vêm sendo encontrados no solo, em águas superficiais e subterrâneas. O objetivo deste estudo foi avaliar a ecotoxicidade dos resíduos químicos originados a partir da oxidação do 17? estradiol, via peróxido de hidrogênio, em um processo destinado à remoção química destes hormônios em solução de acetona, e em diferentes pHs. As análises foram feitas utilizando cromatografia gasosa de alta resolução e bioteste com algas do gênero Euglenas gracillis. Os resultados foram baseados nas comparações de análises pré-processo oxidativo avançado (POA) e pós POA. Observou-se que os resultados obtidos na condição de pH 5,0, com tempo de 20 minutos, apresentou um bom rendimento, porém com mudança de comportamento dos bioindicadores. Em pH 7,0, com tempo de 20 minutos, o rendimento foi menor, porém não houve demonstração de atividade ecotoxicológica...


Assuntos
Humanos , Estradiol/toxicidade , Peróxido de Hidrogênio/análise , Cromatografia Gasosa , Poluição Ambiental
5.
Eng. sanit. ambient ; Eng. sanit. ambient;19(2): 105-112, Apr-Jun/2014. tab, graf
Artigo em Português | LILACS | ID: lil-707059

RESUMO

A cavitação hidrodinâmica se apresenta como um processo oxidativo avançado (POA), permitindo integrar-se aos processos de tratamento de água para consumo humano. Esta pesquisa teve como objetivo investigar os efeitos de diferentes reatores de cavitação hidrodinâmica para tratar água contaminada com esgoto doméstico, avaliando a contaminação microbiológica e os parâmetros físico-químicos. Foram construídos três modelos de reatores com diferentes rotores (R1, R2 e R3). Os resultados obtidos nos reatores R1, R2 e R3 mostraram redução nas concentrações dos parâmetros químicos em todas as amostras, particularmente nitritos, nitratos, bicarbonatos e dureza total, ao passo que a contaminação microbiológica teve inativação completa dos microrganismos estudados (coliformes totais e Escherichia coli).


The hydrodynamic cavitation is presented as an advanced oxidation process (AOP), allowing to integrate the processes of water treatment for human consumption. This research aimed to investigate the effects of different hydrodynamic cavitation reactors for treating water contaminated with sewage, evaluating the microbiological contamination and physicochemical parameters. Three models were constructed with different rotors reactors (R1, R2 and R3). The results obtained in the reactors R1, R2 and R3 have shown a reduction in the concentrations of chemical parameters in all samples, particularly nitrites, nitrates, bicarbonates, and total hardness, while the microbiological contamination was completely inactivation (total coliforms and Escherichia coli).

6.
Eng. sanit. ambient ; Eng. sanit. ambient;19(1): 61-66, Jan-Mar/2014. graf
Artigo em Português | LILACS | ID: lil-703064

RESUMO

Este estudo avaliou a degradação oxidativa do herbicida pós-emergente Basagran(r) 600 por fotólise e fotocatálise, usando TiO2 como catalisador, comparando-se a eficiência de ambos os processos. Os experimentos foram realizados irradiando-se soluções aquosas do herbicida em um reator do tipo slurry. Os tratamentos foram acompanhados por espectrofotometria de absorção na região do UV-visível observando-se a banda centrada em 335 nm. O primeiro processo mostrou-se pouco efetivo, sendo observada mínima redução dos valores de absorvância. Já o segundo foi muito mais eficiente, sendo observado, após 270 min de irradiação, 100% de redução da absorvância da banda no comprimento de onda estudado. Este processo seguiu uma cinética de pseudo-primeira ordem e teve constante de velocidade (k) estimada de 0,0116 min-1.


This study evaluated the oxidative degradation of the post-emerging herbicide Basagran(r) 600 by photolysis and photocatalysis using TiO2 as catalyst, and both processes were compared in their efficiency. The experiments were done irradiating aqueous solutions of the herbicide in a slurry type reactor. The treatments were accompanied by spectrophotometry in the UV-visible range observing the band centered in 335 nm. The first process showed rather ineffective, being observed minimal reduction of the absorbance values. On the other hand, the second process was much more efficient, being observed, after 270 min of irradiation, 100% absorbance reduction of the band in the choose wavelength. This process followed pseudo-first-order kinetic and the estimated rate constant (k) was 0.0116 min-1.

7.
Braz. j. pharm. sci ; 50(1): 25-40, Jan-Mar/2014. tab, graf
Artigo em Inglês | LILACS | ID: lil-709538

RESUMO

The frequent occurrence of pharmaceuticals in the aquatic environment requires an assessment of their environmental impact and their negative effects in humans. Among the drugs with high harmful potential to the environment are the antibiotics that reach the environment not only, as may be expected, through the effluents from chemical and pharmaceutical industries, but mainly through the sewage and livestock; because around 25 to 75% of the ingested drugs are excreted in unchanged form after the passage through the Gastro-Intestinal Tract. Tetracycline has high world consumption, representing a human consumption of about 23 kg/day in Brazil in 2007. At the moment, researches are being made to develop new tetracycline that incorporate heavy metals (Hg, Cd, Re, Pt, Pd) to their structures in order to increase their bactericidal effect. The conventional wastewater treatment plants are not able to degrade complex organic molecules to reduce their toxicity and improve their biodegradability. For this reason new technologies, i.e., the advanced oxidation processes, are being developed to handle this demand. The objectives of this study are to review the literature on the processes of obtaining tetracycline, presenting its waste treatment methods and evaluation of their environmental impact.


A ocorrência frequente de fármacos no meio aquático exige a avaliação do seu impacto ambiental e seus efeitos negativos em seres humanos. Dentre os fármacos com maior potencial de impacto ambiental estão os antibióticos, que chegam ao meio ambiente através dos efluentes de indústrias químico-farmacêuticas e, principalmente, através de esgotos domésticos e criação de animais, visto que 25% a 75% dos fármacos são excretados em forma inalterada após passagem pelo Trato Gastrointestinal. Parcela significativa do consumo mundial dos antibióticos corresponde à classe das tetraciclinas, representando consumo humano de 23 kg/dia no Brasil, em 2007. Atualmente, há pesquisas de novas tetraciclinas que incorporam metais pesados (Hg, Cd, Re, Pt, Pd) às suas estruturas com o intuito de aumentar suas atividades bactericidas. As estações de tratamento de águas residuais convencionais não são capazes de degradar moléculas orgânicas complexas, diminuir a sua toxicidade e melhorar a sua biodegradabilidade. Por esta razão, as novas tecnologias, como, por exemplo, os processos oxidativos avançados, estão sendo desenvolvidos para lidar com esta demanda. Os objetivos deste trabalho são fazer uma revisão da literatura sobre os processos de obtenção de tetraciclinas, apresentar métodos de tratamento de seus resíduos e avaliar o seu impacto ambiental.


Assuntos
Humanos , Tetraciclinas/análise , /análise , /análise , Efluentes Industriais/prevenção & controle , Poluição Ambiental/efeitos adversos
8.
Braz. j. pharm. sci ; 50(1): 41-54, Jan-Mar/2014. tab, graf
Artigo em Inglês | LILACS | ID: lil-709547

RESUMO

Over the past few decades, a high number of pharmaceuticals have been detected in surface, ground and drinking waters. This contamination comes from domestic sewage, livestock, hospitals and chemical-pharmaceutical industries. Typical examples of these pollutants are the fluoroquinolones - powerful antibiotics used in human and veterinary medicine. The presence of fluoroquinolones in the environment can pose a serious threat to the ecosystem and to human health due to their high consumption globally: in 1998, around 120 tons were produced. Even at low environmental concentrations, antibiotics stimulate bacterial resistance. The consequences of the presence of fluoroquinolones in the environment are not fully understood, but are known to be toxic to plants and aquatic organisms. Approximately 85% of the fluoroquinolones present in influents can be removed by conventional wastewater treatment plants, but the removed fraction is frequently accumulated in the sludge, which is sometimes used as fertilizer, representing an additional input route into the environment. The removal of fluoroquinolones by biological treatment is ineffective, and it is believed that only advanced oxidation technologies are able to destroy these emerging pollutants.


Nas últimas décadas, um grande número de fármacos tem sido identificado em águas superficiais, subterrâneas e potáveis. Tal contaminação advém do esgoto doméstico, hospitais, criação de animais e das indústrias químico-farmacêuticas. Exemplos típicos desses poluentes são as fluoroquinolonas – potentes antibióticos empregados na medicina humana e veterinária. A presença de fluoroquinolonas no meio ambiente pode representar uma séria ameaça para o ecossistema e para a saúde humana devido ao alto consumo mundial: em 1998 foram produzidas, aproximadamente, 120 toneladas. Mesmo em baixas concentrações, antibióticos podem estimular a resistência bacteriana. As consequências da presença de fluoroquinolonas no ambiente não são completamente compreendidas, mas sabe-se que são tóxicas para plantas e organismos aquáticos. Aproximadamente 85% das fluoroquinolonas presentes em efluentes podem ser removidos em estações de tratamento de efluentes convencionais, porém a fração removida é frequentemente acumulada no lodo, muitas vezes usado como fertilizante, o que representa uma rota adicional de entrada desses compostos no ambiente. A remoção de fluoroquinolonas por meio de tratamento biológico não é eficiente, e acredita-se que somente as tecnologias de oxidação avançada sejam capazes de degradar esses poluentes emergentes.


Assuntos
/análise , Fluoroquinolonas/toxicidade , Poluentes da Água/toxicidade , Poluição Ambiental/análise
9.
Eng. sanit. ambient ; Eng. sanit. ambient;17(2): 129-136, abr.-jun. 2012. graf, tab
Artigo em Português | LILACS | ID: lil-665937

RESUMO

A contaminação de águas por misturas diesel/biodiesel pode causar grandes impactos ambientais, relacionados à presença de compostos orgânicos recalcitrantes e tóxicos, inviabilizando o uso de processos biológicos de tratamento. A avaliação da biodegradabilidade, nas proporções B0, B25, B50, B75 e B100 (os números especificam o percentual em massa de biodiesel na mistura), indicou que a adição de biodiesel em teores acima de 50% aumenta a biodegradabilidade, alcançando 60 e 80% para B50 e B75, respectivamente. Na aplicação do processo Fenton, a remoção da matéria orgânica foi superior a 80% em todas as misturas, exceto para B0, que apresentou remoção máxima de 50%. A oxidação por Fenton se ajustou a um modelo cinético de pseudo-segunda ordem em relação à concentração de matéria orgânica, e resultou em aumento da biodegradabilidade de até 150%.


Waters contaminated with diesel/biodiesel and their blends can cause major environmental impacts, due to the presence of toxic and recalcitrant organic compounds, which invalidate the use of biological treatment processes. Evaluation of biodegradability of the blends B0, B25, B50, B75 and B100 (the numbers specify the mass percentage of biodiesel in the blend) indicated that the addition of biodiesel at concentrations above 50% increased biodegradation, reaching 60 and 80% for B50 and B75, respectively. When the Fenton process was used, removal of organic matter was greater than 80 % in all blends, except for B0, which showed maximum removal of 60%. Oxidation by Fenton was fitted with a pseudo-second order kinetic model in relation to the concentration of organic matter and resulted in increased biodegradation of up to 150%.

10.
Eng. sanit. ambient ; Eng. sanit. ambient;16(3): 261-270, jul.-set. 2011. ilus, tab
Artigo em Português | LILACS | ID: lil-601964

RESUMO

Os efluentes têxteis, geralmente, são carregados de corantes não biodegradáveis, o que dificulta o seu tratamento. Dentre as novas alternativas de tratamento estudadas, estão os Processos Oxidativos Avançados (POA). Os mesmos são processos com potencial de produzir radicais hidroxila (•OH), espécies altamente oxidantes, capazes de mineralizar a matéria orgânica. Assim, o objetivo deste trabalho foi estudar a aplicação dos POA (Fenton, foto-Fenton e UV/H2O2) no tratamento de efluente têxtil sintético contendo o corante Preto Biozol UC. Dentre os processos estudados, o mais eficiente foi o foto-Fenton (H2O2 = 1.500 mg.L-1 e Fe2+ = 75 mg.L-1), em pH = 3, que obteve 95,4 por cento e 73,0 por cento para as remoções de cor e demanda química de oxigênio (DQO), respectivamente.


The textile wastewater is usually loaded with non-biodegradable dyes, which hinder its treatment. Advanced Oxidation Processes (AOP) are among new treatment alternatives. They are processes with potential to produce hydroxyl radicals (•OH), highly oxidizing species, capable of mineralizing the organic matter. Thus, the aim of this work was to study the application of the AOP (Fenton, photo-Fenton and UV/H2O2) in the treatment of synthetic textile wastewater containing the Black Biozol UC dye. Among the studied processes, the most efficient was photo-Fenton (H2O2 = 1,500 mg.L-1 and Fe 2+ = 75 mg.L-1), at pH = 3, for color and chemical oxygen demand (COD) removals of 95.4 percent and 73.0 percent, respectively.

11.
Eng. sanit. ambient ; Eng. sanit. ambient;14(1): 1-8, jan.-mar. 2009. ilus, graf, tab
Artigo em Português | LILACS | ID: lil-512055

RESUMO

No presente trabalho, processos de oxidação avançada, Fe2+/H2O2 e UV/H2O2, e de fotólise (UV) foram empregados na descoloração de dois efluentes sintéticos, contendo corantes tipo índigo e azo, e de um efluente de lavanderia industrial. Experimentalmente, soluções em concentração de 20 mg/L dos corantes índigo carmim e vermelho congo, respectivamente 43 µmol/L e 29 µmol/L, e o efluente têxtil (pH = 3) foram submetidos a diferentes condições oxidantes sob temperatura ambiente (27 ºC). As remoções de cor e de DQO foram avaliadas em cada sistema oxidativo estudado. Em geral, os resultados obtidos mostraram que os processos utilizados são muito promissores na descoloração dos efluentes. A descoloração completa das soluções foi alcançada nos processos Fenton e com UV/H2O2. Estudos cinéticos revelam que a taxa de descoloração em meio aquoso segue uma cinética de pseudo-primeira ordem em relação à concentração do corante.


In the present work, advanced oxidation processes, Fe2+/H2O2 and UV/H2O2, and direct photolysis (UV light) have been applied in the decolorization of two synthetic wastewater containing indigo and azo dyes and laundry effluent. Individual aqueous solutions containing 20 mg/L indigo carmine and congo red dyes (43 µmol/L and 29 µmol/L, respectively) and textile laundry wastewater at pH 3 were subjected to different experimental conditions in the oxidation reactions at room temperature (27 ºC). Color and COD removals were evaluated for each oxidation systems. The results showed that the utilized processes are able to successfully decolorize the wastewaters. Complete bleaching was achieved by Fenton and UV/H2O2. Also, kinetics investigations revealed that the decolorization follows pseudo-first order kinetic with respect to the dye concentration.

12.
Rev. colomb. quím. (Bogotá) ; 34(2): 161-173, dic. 2005. ilus, graf, tab
Artigo em Espanhol | LILACS | ID: lil-636576

RESUMO

Con la creciente presión hacia un uso más racional del recurso hídrico, el desarrollo de tecnologías apropiadas de tratamiento de aguas es cada vez más urgente. Debido a ello, en los últimos años se han propuesto procesos de oxidación fotoquímicos y electroquímicos como alternativa para el tratamiento de aguas contaminadas con sustancias antropogénicas difícilmente biodegradables, así como para eliminar bacterias en aguas destinadas al consumo humano. El objetivo de este trabajo es presentar algunas de nuestras más recientes investigaciones que demuestran que tanto la electroquímica como la fotoquímica, al igual que el acople de estos procesos con tratamientos biológicos, son alternativas muy prometedoras para aumentar la calidad del agua.


With the increasing pressure on a more effective use of water resources, the developpement of appropriate water treatment technologies become more and more important. Photochemical and electrochemical oxidation processes have been proposed in recent years as an attractive alternative for the treatment of contaminated water containing anthropogenic substances hardly biodegradable as well as to purify and disinfect drinking waters. The aim of this paper is to present some of our last results demonstrating that electrochemical, photochemical, and the coupling of these processes with biological systems are very promising alternativesfor the improvement of the water quality.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA