Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Adicionar filtros








Intervalo de ano
1.
Crit. Care Sci ; 35(4): 367-376, Oct.-Dec. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1528492

RESUMO

ABSTRACT Objective: To assess the impact of different vertical positions on lung aeration in patients receiving invasive mechanical ventilation. Methods: An open-label randomized crossover clinical trial was conducted between January and July 2020. Adults receiving invasive mechanical ventilation for > 24 hours and < 7 days with hemodynamic, respiratory and neurological stability were randomly assigned at a 1:1 ratio to the sitting position followed by passive orthostasis condition or the passive orthostasis followed by the sitting position condition. The primary outcome was lung aeration assessed using the lung ultrasound score (score ranges from 0 [better] to 36 [worse]). Results: A total of 186 subjects were screened; of these subjects, 19 were enrolled (57.8% male; mean age, 73.2 years). All participants were assigned to receive at least one verticalization protocol. Passive orthostasis resulted in mean lung ultrasound scores that did not differ significantly from the sitting position (11.0 versus 13.7; mean difference, -2.7; [95%CI -6.1 to 0.71; p = 0.11). Adverse events occurred in three subjects in the passive orthostasis group and in one in the sitting position group (p = 0.99). Conclusion: This analysis did not find significant differences in lung aeration between the sitting and passive orthostasis groups. A randomized crossover clinical trial assessing the impact of vertical positioning on lung aeration in patients receiving invasive mechanical ventilation is feasible. Unfortunately, the study was interrupted due to the need to treat COVID-19 patients. ClinicalTrials.gov registry: NCT04176445


RESUMO Objetivo: Avaliar o impacto de diferentes posicionamentos verticais na aeração pulmonar em pacientes em ventilação mecânica invasiva. Métodos: Trata-se de ensaio clínico aberto, randomizado e transversal, realizado entre janeiro e julho de 2020. Adultos em ventilação mecânica invasiva por mais de 24 horas e menos de 7 dias com estabilidade hemodinâmica, respiratória e neurológica foram distribuídos aleatoriamente em uma proporção de 1:1 à postura sentada seguida da condição de ortostatismo passivo ou o ortostatismo passivo seguido de postura sentada. O desfecho primário foi a aeração pulmonar avaliada pelo lung ultrasound score. O escore varia de zero (melhor) a 36 (pior). Resultados: Foram selecionados 186 indivíduos; destes, 19 foram incluídos (57,8% do sexo masculino; média idade de 73,2 anos). Todos os participantes foram selecionados para receber pelo menos um protocolo de verticalização. O ortostatismo passivo resultou em escores médios de aeração pulmonar por ultrassonografia que não diferiram significativamente da postura sentada (11,0 versus 13,7; diferença média, -2,7; IC95% -6,1 a 0,71; p = 0,11). Ocorreram eventos adversos em três indivíduos no grupo ortostatismo passivo e em um no grupo postura sentada (p = 0,99). Conclusão: Esta análise não encontrou diferenças significativas na aeração pulmonar entre os grupos ortostatismo passivo e postura sentada. É factível conduzir um estudo clínico transversal randomizado para avaliar o impacto do posicionamento vertical na aeração pulmonar em pacientes em ventilação mecânica invasiva. Infelizmente, o estudo foi interrompido devido à necessidade de tratar pacientes com COVID-19. Registro ClinicalTrials.gov: NCT04176445

2.
Eng. sanit. ambient ; 25(2): 413-423, mar.-abr. 2020. tab, graf
Artigo em Português | LILACS-Express | LILACS | ID: biblio-1098204

RESUMO

RESUMO No presente trabalho, foi avaliado o desempenho de um sistema de lodo ativado em batelada, com módulo de filtração, proporcionado por uma manta geotêxtil, na remoção de matéria orgânica presente em esgoto sanitário. O reator em escala piloto tinha volume útil de 85 L e foi operado durante 182 dias, com tempo total de ciclo de 24 horas de duração e idade do lodo (θc) de 25 dias. O sistema foi composto de um reator convencional (SB1), utilizado como controle e operado nas mesmas condições que o SM1, o qual utilizou a filtração em manta geotêxtil. Para confecção dos três módulos de filtração, foi utilizada uma manta sintética não tecida combinada com três tipos de espaçadores: tela antiderrapante em poliéster com revestimento em PVC (etapa I) durante 56 dias, geomanta tridimensional de filamentos de polipropileno termosoldados (etapa II) durante 49 dias e manta acrílica 100% poliéster (etapa III) durante 76 dias. A concentração de oxigênio dissolvido (OD) manteve-se na faixa de 3 mgO2.L-1, a relação alimento (A)/microrganismo (M) variou de 0,2 a 0,1 gDBO5.gSSV-1.d-1, e a carga orgânica média aplicada mudou de 0,194 a 0,267 kgDQO.m-3.d.-1. A remoção da turbidez manteve-se na faixa de 97%, a de matéria orgânica em termos de demanda bioquímica de oxigênio (DBO5) foi de 93% e entre 87 e 93% para o parâmetro demanda química de oxigênio (DQO), com o reator SM1 apresentando valores de eficiência e estabilidade operacional superiores ao SB1.


ABSTRACT This work evaluated the performance of a batch activated sludge system with a filtration module, provided by a geotextile blanket to remove organic matter present in sewage. The pilot-scale reactor had a useful volume of 85L, and it was operated for 182 days, with a total cycle time of 24 hours, and sludge age (θc) 25 days. The system was based on a conventional controller (SB1), used as a control and operated under the same conditions as the reactor (SM1) using geotextile blanket filtration. The preparation of the three filtration modules was applied to a non-woven synthetic blanket combined with three types of spacers: PVC-coated non-slip polyester mesh (Step I) for 56 days, three-dimensional geo-mat of thermosolded polypropylene filament (Step II) for 49 days, and 100% polyester acrylic blanket (Step III) for 76 days. The OD concentration remained in the range of 3 mgO2L-1, an F/M ratio ranging from 0.2 to 0.1 gBOD5. gVSS-1d-1 and the organic loading rate average applied ranged from 0.194 to 0.267 kg COD / m3.d.-1. Turbidity removal remained in the range of 97%, and the organic matter removal in terms of BOD5 was 93%, and from 87 to 93% in terms of COD, with SM1 reactor showing efficiency and stability values higher than SB1.

3.
Eng. sanit. ambient ; 22(4): 611-623, jul.-ago. 2017. tab, graf
Artigo em Português | LILACS | ID: biblio-891554

RESUMO

RESUMO Este artigo busca consolidar as principais características, vantagens e desvantagens de métodos disponíveis no meio técnico e científico para o controle de odores e corrosão em redes coletoras e estações de tratamento de esgoto, trazendo uma abordagem atualizada sobre soluções preventivas relacionadas à concepção e à operação de sistemas de esgotamento, com adição de compostos químicos ou aeração em fase líquida. São apresentados os princípios de cada técnica e consolidadas as principais diretrizes para o projeto de alternativas. Além disso, são apresentadas diretrizes para a concepção de soluções corretivas com contenção e exaustão de unidades/fontes potencialmente odorantes, incluindo uma discussão sobre os processos atualmente disponíveis no meio técnico-científico para tratamento de gases odorantes e corrosivos.


ABSTRACT This paper aims to consolidating the main characteristics, advantages and disadvantages of available methods in technical-scientific community to odor and corrosion control in sanitary sewerage systems and treatment plants, taking along an innovative approach on preventive solutions related to sewage systems design and operation with addition of chemicals or liquid phase aeration. The main beliefs of each technique are presented as well as the main guidelines for alternatives design. In addition, guidelines are given for corrective solutions design of covers and exhaust of potentially odorous sources, as well as a brief discussion of processes currently available in the technical-scientific community to the treatment of odorant odorous and corrosive gases.

4.
Eng. sanit. ambient ; 22(3): 437-444, mai.-jun. 2017. tab, graf
Artigo em Português | LILACS | ID: biblio-840428

RESUMO

RESUMO Este trabalho teve como objetivo avaliar quantitativamente a influência da concentração de lodo sobre os fatores que afetam a capacidade de aeração em sistemas de lodo ativado. A investigação experimental foi desenvolvida aplicando a técnica da respirometria, que possibilitou a determinação da taxa de consumo de oxigênio e das variáveis que afetam a transferência de oxigênio. Os resultados experimentais indicam que a concentração de lodo afeta de maneira significativa a capacidade de aeração em sistemas de lodo ativado e, consequentemente, aumenta consideravelmente o consumo de energia. A viabilidade econômica de sistemas que permitem aumento da concentração de lodo, como reatores biológicos com membranas e reatores biológicos com leito móvel, é questionável quando se comparam os custos de implementação com os benefícios resultantes.


ABSTRACT The objective of this research was to evaluate quantitatively the influence of sludge concentration on the factors affecting the aeration capacity in activated sludge systems. The experimental investigation involved the application of respirometry, by which the oxygen consumption rate was determined and allowed evaluation of the effect of concentration on the variables that affect oxygen transfer. The experimental results indicated that the sludge concentration has a strong effect on aeration capacity and consequently on the energy consumption. The economic feasibility of systems that allow operation at high concentration, like membrane bioreactor and moving bed biofilm reactor, is questionable when the costs of implementation are compared to the resulting benefits.

5.
Ciênc. rural ; 46(11): 1917-1923, Nov. 2016. tab, graf
Artigo em Inglês | LILACS | ID: lil-796078

RESUMO

ABSTRACT: Aeration is currently the most commonly used technique to improve the drying and storage of grain, depending on temperature and water content of the grain, as of the temperature and relative humidity of the outside air. In order to monitor temperature and humidity of the grain mass, it is possible to have a network of sensors in the cells of both internal and external storage. Use of artificial intelligence through Fuzzy theory, has been used since the 60s and enables their application on various forms. Thus, it is observed that the aeration of grain in function of representing a system of controlled environment can be studied in relation to the application of this theory. Therefore, the aim of this paper is to present an embedded Fuzzy control system based on the mathematical model of CRUZ et al. (2002) and applied to the Arduino platform, for decision support in aeration of grain. For this, an embedded Arduino system was developed, which received the environmental values of temperature and humidity to then be processed in a Fuzzy controller and return the output as a recommendation to control the aeration process rationally. Comparing the results obtained from the graph presented by LASSERAN (1981) it was observed that the system is effective.


RESUMO: A aeração é a técnica mais utilizada para melhorar a secagem e as condições de armazenamento de grãos, dependendo da temperatura e teor de água do grão, e da temperatura e da umidade relativa do ar externo. O controle da aeração depende do monitoramento da temperatura e da umidade da massa de grãos, podendo-se utilizar uma rede de sensores nas células de armazenamento tanto interna como externamente. A utilização de inteligência artificial pela aplicação da teoria Fuzzy vem sendo utilizada desde a década de 60 e pode ser usada em diversos meios. Assim, observa-se que a aeração de grãos, por ser um sistema de ambiência controlada, pode ser objeto de estudo na aplicação dessa teoria. Diante disso, objetiva-se com este trabalho apresentar um sistema embarcado de controle Fuzzy, baseado no modelo matemático de CRUZ et al. (2002) e aplicados em plataforma Arduino, para suporte a decisão na aeração de grãos. Para tanto, foi desenvolvido um sistema embarcado em Arduino, o qual recebe os valores ambientais: temperatura e umidade para então processar em um controlador Fuzzy e retornar como saída uma recomendação de aeração para controlar o processo de forma racional. Comparando-se os resultados obtidos com o gráfico apresentado por LASSERAN (1981), observasse que o sistema é eficaz.

6.
Rev. CEFAC ; 17(5): 1432-1440, sept.-out. 2015. tab
Artigo em Português | LILACS | ID: lil-765113

RESUMO

Resumo:OBJETIVO:observar se existe relação entre força muscular respiratória e área da aeração nasal em crianças respiradoras orais.MÉTODOS:trata-se de um estudo do tipo observacional, transversal comparativo entre dois grupos. Participaram 32 crianças com Respiração Oral secundária à rinite alérgica (21 meninos e 11 meninas) e 30 respiradoras nasais sem rinite alérgica (09 meninos e 21 meninas), 7 a 12 anos, submetidas à avaliação da aeração nasal com o espelho de Altmann e à avaliação da força muscular respiratória com o manovacuômetro digital (MVD(r)30).RESULTADOS:não houve correlação entre aeração nasal e força muscular respiratória em cada subgrupo. Houve diferença comparando-se valores das pressões expiratórias máximas entre meninos e meninas respiradores orais (p=0,0064) e entre meninos e meninas respiradores nasais (p=0,0030). Também houve diferença das pressões inspiratórias máximas entre meninos e meninas respiradores orais (p=0,0324) e entre meninos e meninas respiradores nasais (p=0,0210).CONCLUSÃO:não foi possível confirmar a relação entre a área de aeração nasal e a força muscular respiratória nos respiradores orais.


Abstract:PURPOSE:to observe whether there is a relationship between respiratory muscle strength and degree of nasal aeration in Mouth Breathing children.METHODS:this is an observational and a comparative cross-sectional study. The subjects were 32 Mouth Breathing children with allergic rhinitis (21 boys and 11 girls) and 30 nasal breathing without allergic rhinitis (09 boys and 21 girls), 7-12 years, subjected to evaluation for nasal aeration with Altmann mirror and to evaluation of respiratory muscle strength with digital manovacuometer (MVD(r)30).RESULTS:there was no correlation between nasal aeration and respiratory muscle strength in each subgroup. There was difference comparing values ​​of maximal expiratory pressure between mouth breathers boys and girls (p=0,0064), and between nasal breathers boys and girls (p=0,0030). There was also difference maximal inspiratory pressure between mouth breathers boys and girls (p=0,0324), and between nasal breathers boys and girls (p=0,0210).CONCLUSION:it was not possible to confirm that there is a relationship between the degree of nasal aeration and respiratory muscle strength in Mouth Breathing.

7.
Eng. sanit. ambient ; 18(1): 9-14, jan.-mar. 2013. ilus, tab
Artigo em Português | LILACS | ID: lil-676953

RESUMO

A injeção de misturas de ar e água na forma de jatos bifásicos é bastante usada para a aeração artificial em tanques e corpos hídricos. No presente trabalho, foram realizados experimentos para investigar a transferência de massa induzida por estes jatos em um tanque de aeração. Os resultados forneceram eficiências de transferência de oxigênio padrão variando entre aproximadamente 5 e 9%. Combinando-se os dados obtidos nesta pesquisa com os disponíveis na literatura, foram geradas correlações adimensionais para o coeficiente de transferência de massa em função da fração volumétrica de ar e do número de Froude densimétrico. Finalmente, os resultados foram aplicados a situações práticas envolvendo sistemas de aeração por jatos bifásicos.


The injection of air-water mixtures through two-phase jets is widely used for artificial aeration in tanks and water bodies. In this study, experiments were conducted to investigate mass transfer induced by such jets in an aeration tank. The results provided standard oxygen transfer efficiencies ranging from about 5 to 9%. Combining the results obtained here with those from previous investigations allowed to generate dimensionless correlations for the mass transfer coefficient as a function of the gas volume fraction and the densimetric Froude number. Finally, the results were applied to practical situations involving two-phase jet aeration systems.

8.
Biosci. j. (Online) ; 28(Supplement 1 - XXXIII Congresso Brasileiro de Ciência do Solo): 203-211, 2012. tab, graf
Artigo em Inglês | LILACS | ID: biblio-912182

RESUMO

The implantation and development of alternative crops to production of biofuel are dependents of soil structural quality. The physic nut has been considered as one of the promising sources of biofuel. The objective of this study was to quantify the influence of use systems on some indicators of soil physical quality and to identify critical values of bulk density and air-filled porosity to crop development of an Alfisol under conventional system of physic nut. For the evaluation of physical indicators of soil quality, samples were collected with disturbed and indisturbed structure in different sampling positions (crop row and interrow). The samples were taken of the layers 0.00 - 0.05; 0.05 - 0.10 and 0.10 - 0.20 m depth. In the conditions of this study, concluded that: i) except to 0.10 to 0.20 m depth, the sampling positions influenced all soil physical parameters; ii) the crop row position presented higher macroporosity and total porosity in 0.00 to 0.10 m depth; iii) the critical air-filled porosity and bulk density values for plant growth were 0.74 and 1.49 Mg m-3 and iv) considering the bulk density and air-filled porosity only the crop row position no indicate restrictive values to plants development.


A implantação e o desenvolvimento de culturas alternativas para a produção de biocombustível são dependentes da qualidade estrutural do solo. O pinhão manso tem sido considerado uma fonte promissora de biocombustível. O objetivo deste estudo foi verificar a influência dos sistemas de uso em alguns parâmetros físicos e identificar valores críticos ao desenvolvimento de plantas de um Argissolo Vermelho Amarelo sob sistema convencional de pinhão manso. Coletaram-se amostras com estrutura alterada e inalterada, nas posições linha e entrelinha de cultivo do pinhão manso e nas camadas de 0,00 a 0,05; 0,05 a 0,10 e 0,10 a 0,20 m. Nas condições deste estudo, conclui-se que: i) as posições de amostragem influenciam os parâmetros físicos com exceção da camada de 0,10 - 0,20 m; ii) na camada de 0,00 - 0,10 m, o solo na posição linha de cultivo apresentou uma maior macroporosidade e porosidade total do solo; iii) os valores críticos ao desenvolvimento de plantas referentes ao índice de vazios e de densidade do solo são 0,74 e 1,49 Mg m- 3 e v) considerando o índice de vazios e a densidade do solo, somente o solo na posição linha de cultivo não indica valores limitantes ao desenvolvimento da cultura.


Assuntos
Qualidade do Solo , Características do Solo , Jatropha , Biocombustíveis
9.
Eng. sanit. ambient ; 16(4): 353-360, out.-dez. 2011. ilus, tab
Artigo em Português | LILACS | ID: lil-614699

RESUMO

Atividades humanas aceleram o processo natural de eutrofização das águas, favorecendo a floração de algas e cianobactérias. Estes organismos emitem os compostos 2-metilisoborneol (MIB) e geosmina, que conferem gosto e odor de mofo e terra à água. A presença destes compostos se estende à água potável uma vez que os processos convencionais de tratamento são insuficientes para removê-los. Esta pesquisa foi realizada com o objetivo de avaliar alternativas de processos de tratamento para a remoção de MIB e geosmina da água. Os processos estudados foram aeração em cascata, dessorção por ar e nanofiltração. Os resultados sugerem a possibilidade de remoção quase total de MIB e geosmina da água através do sistema de nanofiltração, enquanto que os processos baseados em aeração e dessorção foram relativamente ineficientes.


Human activities accelerate the natural process of eutrophication, favouring the occurrence of algae and cyanobacterial blooms. These organisms emit the compounds 2-methylisoborneol (MIB) and geosmin, which confer earthy and moldy taste and odor to water. The presence of MIB and geosmin is extended to drinking water inasmuch they are not completely removed by the processes used in conventional treatment. This research was conducted to evaluate the capability of alternative treatment processes to remove MIB and geosmin from water. The processes studied were cascade aeration, air stripping, and nanofiltration. The results suggested that MIB and geosmin can be almost completely removed by nanofiltration, while the processes based on aeration and stripping were relatively inefficient.

10.
Acta sci., Biol. sci ; 33(2): 125-132, Apr. - Jun. 2011. tab
Artigo em Inglês | LILACS | ID: biblio-875399

RESUMO

A simulation was conducted to determinate the impact caused by the combination of Litopenaeus vannamei respiratory rate (mg O2 shrimp-1 h-1), the behavior of SOTR (kg O2 h-1) of mechanical aerators as a function of salinity, as well as the oxygen consumption rate of the pond water and soil (mg O2 L-1 h-1) on the aeration of shrimp ponds (1, 10, 50 and 100 ha) stocked with different densities (10, 40 and 120 shrimp m-2), salinities (1, 13, 25 and 37 ppt), temperatures (20, 25 and 30°C), and shrimp wet weight (5, 10, 15 and 20 g). Results showed that under lower salinity, with larger shrimp, and higher stocking density, higher will be the quantity of required 2-HP aerators to keep dissolved oxygen over 50% saturation. In addition, under low salinity, with 5 and 10 g shrimp, independent of stocking density, more aerators per hectare are required and electricity cost is higher at 20°C and salinity 1 ppt. Less aerators and lower electricity cost was observed at 30°C, salinities of 25 and 37 ppt, and shrimp of 15 and 20 g.


Baseado em estudos de respiração de Litopenaeus vannamei (mg O2 camarão-1 h-1), comportamento do Standard Oxygen Transfer Rate (SOTR, kg O2 h-1) de aeradores mecânicos em função da salinidade, assim como as taxas de respiração da água e do solo (mg O2 L-1 h-1), uma simulação foi realizada a fim de determinar o impacto que estas três variáveis juntas têm sobre a aeração de viveiros (1, 10, 50 e 100 ha), estocados com diferentes densidades (10, 40 e 120 camarões m-2) em salinidades de 1, 13, 25 e 37 ppm, temperaturas de 20, 25 e 30°C e peso úmido dos camarões de 5, 10, 15 e 20 g. Os resultados mostraram que em salinidades mais baixas, com animais maiores e maiores densidades de estocagem, maior será a quantidade de aeradores de 2 cv necessários para manter o oxigênio dissolvido acima de 50% da saturação. Igualmente, em baixas salinidades e com camarões de 5 e 10 g, independente da densidade de estocagem, mais aeradores por hectare serão necessários, e o custo com eletricidade é máximo em temperatura e salinidade de 20°C e 1 ppm. A menor exigência de aeradores e de eletricidade é obtida a uma temperatura de 30°C, salinidades de 25 a 37 ppm e com camarões de 15 e 20 g.


Assuntos
Artemia , Aeração , Oxigênio
11.
Eng. sanit. ambient ; 15(1): 75-82, jan.-mar. 2010. ilus, tab
Artigo em Português | LILACS | ID: lil-545400

RESUMO

Jatos bifásicos do tipo gás-líquido são bastante usados nas engenharias sanitária e ambiental para fins de aeração artificial e mistura turbulenta. O presente trabalho investiga a turbulência gerada por meio desses jatos em um tanque de água, utilizando velocimetria por imagem de partículas. As condições experimentais incluíram jatos bifásicos com frações volumétricas de ar de até 70 por cento e números de Reynolds variando entre 10.600 e 17.700. Os resultados dos ensaios indicaram que a fração volumétrica de ar afeta consideravelmente as propriedades turbulentas da fase líquida, enquanto o número de Reynolds apresenta efeito secundário. Correlações adimensionais foram então obtidas para expressar a energia cinética turbulenta e a taxa de dissipação de energia em função desses dois parâmetros. Finalmente, são apresentadas possíveis aplicações dos resultados deste trabalho.


Two-phase gas-liquid jets are widely used in the sanitary and environmental engineering field for artificial aeration and turbulent mixing. The present work investigates the turbulence generated by these jets in a water tank, using particle image velocimetry. The experimental conditions included two-phase jets with gas volume fractions of up to 70 percent and Reynolds numbers ranging from 10,600 to 17,700. The results indicated that the gas volume fraction affects significantly the turbulent properties of the liquid phase, while the Reynolds number presents a secondary effect. Dimensionless correlations were then obtained to express the turbulent kinetic energy and dissipation rate as a function of these two parameters. Finally, possible applications of the results obtained in this work are presented.

12.
Eng. sanit. ambient ; 13(2): 189-197, abr.-jun. 2008. ilus, graf, tab
Artigo em Português | LILACS | ID: lil-486655

RESUMO

Neste trabalho estuda-se a transferência de massa gás-líquido a partir de bolhas de ar para a água, geradas por um difusor de ar, em uma coluna de aeração, mudando a vazão de ar de 400 L/h a 2000 L/h, o nível de água de 0,50 m a 1,80 m, cujas taxas de aplicação superficial de ar variaram de 3,1 L/m².s a 15,4 L/m².s. Várias características hidrodinâmicas foram medidas, tal como a velocidade ascensional das bolhas de ar e seus diâmetros, fundamentais para verificar o coeficiente de transferência de massa que estão na literatura, usando um equipamento laser para velocimetria não-intrusiva. Após os estudos da transferência de massa, foi concluído que a vazão de ar entre 400 L/h e 800 L/h e o nível de água de 1,80 m apresentou a maior eficiência de transferência de massa, garantindo para estas medidas, dentro da coluna em estudo, maior quantidade de oxigênio dissolvido.


The present work is a study of the mass transfer gas-liquid from air bubbles into water, generated by a diffuser of air, in a column of aeration, changing the air flow from 400 L/h to 2000 L/h, the level of water from 0.50 m to 1.80 m, whose taxes of superficial application of air had varied of 3.1 L/m².s to 15.4 L/m².s. Several hydrodynamics characteristics were measured, such as the velocity range of the air bubbles and their diameter, fundamental to check the mass transfer coefficient that are in literature, by using a laser equipment for non-intrusive velocimetry. After of the study of the mass transfer, it was concluded that the air flow between 400 L/h and 800 L/h and the level of water of 1.80 m was the most efficient of mass transfer, guaranteeing for these measure, into of the column in study, most quantity of dissolved oxygen.

13.
Ciênc. agrotec., (Impr.) ; 32(1): 80-86, jan.-fev. 2008. graf, tab
Artigo em Português | LILACS | ID: lil-479101

RESUMO

Conduziu-se este trabalho, com o objetivo de induzir a estímulo do comportamento fotoautotrófico durante o enraizamento in vitro em brotações de Annona glabra L. Brotações oriundas de cultivo em tubos fechados com tampa e película de PVC (cultivo sem aeração), com tampa sem a película de PVC e tampão de algodão (cultivo com aeração) foram inoculadas em meio WPM suplementado com 4,9 µ M de AIB e 164,4mM de carvão ativado na presença (58,42mM) ou ausência de sacarose. Durante o enraizamento, foram mantidas as mesmas condições de vedação dos tubos de ensaio em que as brotações foram induzidas. Após a inoculação, os tubos contendo os explantes foram mantidos em sala de crescimento sob radiação fotossintética ativa de 45-56 µ mol.m-2.s-1 a 25±3ºC. Os resultados mostraram que o enraizamento das brotações de A. glabra não dependeu do suprimento de sacarose no meio de cultura, em tubos fechados com o tampão de algodão ou tampa plástica sem PVC. A aeração dos tubos de ensaio trouxe incrementos de significativos (até 250 por cento) na matéria seca radicular. A indução de raízes secundárias (laterais) em A. glabra só ocorreu em culturas com aeração, independentemente da presença ou ausência de sacarose no meio de cultura. Com os resultado desse experimento, conclui-se que o estímulo do comportamento fotoautotrófico em A.glabra pode ser obtido com sucesso durante a fase de enraizamento in vitro.


The objective of the present work was to evaluate whether Annona glabra L. shoots are able to acquire the photoautotrophic behavior during the in vitro rooting. In vitro A. glabra shoots originated from cultures in vessels sealed with cap and PVC film (culture without aeration), cap without PVC film or cotton tampon (cultures with aeration), were inoculated in WPM medium supplemented with 4.9 µ M IBA and 164,4mM activated charcoal in the presence (58.42mM) or absence of sucrose. During rooting, the same conditions in which shoots were induced were maintained. After inoculation, the tubes with explants were maintained in growth room under photosynthetic active radiation of 45-56 µ mol.m-2.s-1 and of temperature 25±3ºC. The results showed that the rooting of A. glabra shoots do not depend on the supply of sucrose into culture medium, in vessel with aeration. Aeration of cultures brought expressive increments of dry weight of roots (up to 250 percent). The induction of secondary (side) roots was found only in cultures with aeration, independently of sucrose presence. One concluded that the acquisition of the photoautotrophic behavior in A. glabra may be obtained with success during the in vitro rooting phase.

14.
Rev. CEFAC ; 9(3): 375-382, jul.-set. 2007. ilus, tab
Artigo em Português | LILACS | ID: lil-466180

RESUMO

OBJETIVO: identificar a modificação da aeração nasal após a realização de manobras de massagem e limpeza nasal. MÉTODOS: vinte crianças na faixa etária de quatro a onze anos com diagnóstico de rinite alérgica foram submetidas à avaliação da aeração nasal com o auxílio do espelho milimetrado de Altmann. Inicialmente houve a marcação do ar expirado na placa metálica, posteriormente foram realizadas manobras de massagem e limpeza nasal para retirada da secreção, havendo uma nova marcação para a comparação dos resultados. Foi aplicado o teste Kolmogorov-Smirnov para observar a suposição de normalidade dos dados e o teste t-student para amostras pareadas, sendo todas as conclusões tomadas ao nível de significância de 5 por cento. RESULTADOS: pode-se observar que as médias obtidas da quantificação da aeração nasal após as manipulações e limpeza na região foram significativas p<0,001. CONCLUSÃO: a partir dos resultados obtidos nesta pesquisa foi possível observar um aumento significante na aeração nasal após as manobras de massagem e limpeza nasal.


PURPOSE: to identify the modification of nasal aeration after the accomplishment of maneuvers of massage and nasal cleanness. METHODS: twenty children aging from four to eleven years with diagnosis of allergic rhinitis have been submitted to evaluation of nasal aeration with the Altmann's milimetric mirror. Initially, we was marked the air exhaled on the metallic plate, afterwards we made a massage and nasal cleanness for removing of the secretion, having a new benchmark to compare the results. Kolmogorov-Smirnov test was applied to test the assumption of normality for the data and t-student test for paired samples. All conclusions were taken under 5 percent significance. RESULTS: it was observed that the obtained averages of the nasal aeration after the manipulations and cleanness in the region were significant: p<0,001. CONCLUSION: from the results obtained in this research it was possible to observe a significant increase in the nasal aeration after the massage and nasal cleanness.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA