Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Adicionar filtros








Intervalo de ano
1.
Korean Journal of Anesthesiology ; : 48-51, 2014.
Artigo em Inglês | WPRIM | ID: wpr-173266

RESUMO

A 28-year-old male patient with right maxillar, zygomatic arch, orbital wall, and nasal bone fractures had an orthognathic and nasal surgery. Naso-endotracheal intubation is the first choice during surgical correction of dentofacial deformities in an orthognathic surgery; however, its presence can interfere with concomitant surgical procedures on the nose. Traditionally, the naso-endotracheal tube will be removed and replaced with an oro-endotracheal tube. We changed the endotracheal tube from nasal to oral by using an airway exchange catheter.


Assuntos
Adulto , Humanos , Masculino , Catéteres , Deformidades Dentofaciais , Intubação , Osso Nasal , Procedimentos Cirúrgicos Nasais , Nariz , Órbita , Cirurgia Ortognática , Zigoma
2.
Chinese Journal of Integrated Traditional and Western Medicine in Intensive and Critical Care ; (6): 10-13, 2014.
Artigo em Chinês | WPRIM | ID: wpr-443619

RESUMO

Objective To discuss the clinical application of homemade airway exchange catheter on the extubation of patients with difficult tracheal intubation in intensive care unit(ICU). Methods Sixty-two patients with difficult tracheal intubation who failed their initial extubation trial were randomly divided into conventional group (31 cases)and observation group(31 cases). The patients in the conventional group received routine extubation process,while the patients in the observation group were extubated under the guidance over a homemade airway exchange catheter. The changes in heart rate(HR),blood pressure,respiratory rate(RR)and pulse blood oxygen saturation(SpO2)were compared at 12 hours after extubation,so as the re-intubation rate,intubation success rate at first attempt and re-intubation time in two groups,and the tolerance and complications after extubation were observed. Results After extubation,the HR,blood pressure and RR were increased significantly(all P<0.05), and the SpO2 was much lower in conventional group(P<0.05),while those parameters were changed little and basically in the normal ranges in the observation group. At 12 hours after extubation,the re-intubation rate was much lower(6.45%vs. 25.81%,P<0.05)in the observation group,with shorter re-intubation time(seconds:27±14 vs. 49±28,P<0.01),higher intubation success rate at first attempt(90.32%vs. 54.84%,P<0.01)and better tolerance (77.4% vs. 61.3%,P<0.05)compared with those in the conventional group. There was no severe complication in the observation group,and there were 1 cases of glottic edema with cricothyroid membrane puncture,2 cases of broncheal mucous membrane bleeding and 2 cases of bucking in the conventional group. Conclusion Compared with conventional extubation process,the extubation over homemade airway exchange catheter can increase the rate of extubation,reduce re-intubation rate and the re-intubation time,with favorable tolerance and no occurrence of serious complications,and is one of the safe and effective extubation strategies in patients with difficult tracheal intubation in ICU.

3.
Korean Journal of Anesthesiology ; : 168-171, 2013.
Artigo em Inglês | WPRIM | ID: wpr-59804

RESUMO

The case of a 33-day-old boy with Pierre Robin syndrome using a Cook(R) airway exchange catheter in laryngeal mask airway-guided fiberoptic intubation is presented. After induction with sevoflurane, classical reusable laryngeal mask airway (LMA) #1 was inserted and ultrathin fiberoptic bronchoscope (FOB) was passed through. A Cook(R) airway exchange catheter (1.6 mm ID, 2.7 mm OD) was passed through the LMA under the guidance of the FOB but failed to enter the trachea despite many trials. Then, an endotracheal tube (3.0 mm ID) was mounted on the FOB and railroaded over the FOB. After successful intubation, the Cook(R) airway exchange catheter was placed in the midtrachea through the lumen of the endotracheal tube. Even though the tracheal tube was accidentally displaced out of the trachea during LMA removal, the endotracheal tube could be easily railroaded over the airway exchange catheter.