Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Braz. j. med. biol. res ; 51(2): e6825, 2018.
Artigo em Inglês | LILACS | ID: biblio-1019561

RESUMO

This study aimed to evaluate the feasibility and performance of Arndt-endobronchial blocker (Arndt) combined with laryngeal mask airway (LMA) compared with left-sided double-lumen endobronchial tube (L-DLT) in morbidly obese patients in one-lung ventilation (OLV). In a prospective, randomized double-blind controlled clinical trial, 80 morbidly obese patients (ASA I-III, aged 20-70) undergoing general anesthesia for elective thoracic surgeries were randomly allocated into groups Arndt (n=40) and L-DLT (n=40). In group Arndt, a LMA™ Proseal was placed followed by an Arndt-endobronchial blocker. In group L-DLT, patients were intubated with a left-sided double-lumen endotracheal tube. Primary endpoints were the airway establishment, ease of insertion, oxygenation, lung collapse and surgical field exposure. Results showed similar ease of airway establishment and tube/device insertion between the two groups. Oxygen arterial pressure (PaO2) of patients in the Arndt group was significantly higher than L-DLT (154±46 vs 105±52 mmHg; P<0.05). Quality of lung collapse and surgical field exposure in the Arndt group was significantly better than L-DLT (effective rate 100 vs 90%; P<0.05). Duration of surgery and anesthesia were significantly shorter in the Arndt group (2.4±1.7 vs 3.1±1.8 and 2.8±1.9 vs 3.8±1.8 h, respectively; P<0.05). Incidence of hoarseness of voice and incidence and severity of throat pain at the post-anesthesia care unit and 12, 24, 48, and 72 h after surgery were significantly lower in the Arndt group (P<0.05). Findings suggested that Arndt-endobronchial blocker combined with LMA can serve as a promising alternative for morbidly obese patients in OLV in thoracic surgery.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Obesidade Mórbida/cirurgia , Máscaras Laríngeas/normas , Procedimentos Cirúrgicos Torácicos/instrumentação , Ventilação Monopulmonar/instrumentação , Intubação Intratraqueal/instrumentação , Dor Pós-Operatória/etiologia , Atelectasia Pulmonar , Fatores de Tempo , Faringite/etiologia , Ventiladores Mecânicos/normas , Método Duplo-Cego , Estudos Prospectivos , Reprodutibilidade dos Testes , Resultado do Tratamento , Procedimentos Cirúrgicos Torácicos/métodos , Desenho de Equipamento , Ventilação Monopulmonar/métodos , Duração da Cirurgia , Intubação Intratraqueal/métodos
2.
Braz. j. med. biol. res ; 51(2): e6825, 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-889030

RESUMO

This study aimed to evaluate the feasibility and performance of Arndt-endobronchial blocker (Arndt) combined with laryngeal mask airway (LMA) compared with left-sided double-lumen endobronchial tube (L-DLT) in morbidly obese patients in one-lung ventilation (OLV). In a prospective, randomized double-blind controlled clinical trial, 80 morbidly obese patients (ASA I-III, aged 20-70) undergoing general anesthesia for elective thoracic surgeries were randomly allocated into groups Arndt (n=40) and L-DLT (n=40). In group Arndt, a LMA™ Proseal was placed followed by an Arndt-endobronchial blocker. In group L-DLT, patients were intubated with a left-sided double-lumen endotracheal tube. Primary endpoints were the airway establishment, ease of insertion, oxygenation, lung collapse and surgical field exposure. Results showed similar ease of airway establishment and tube/device insertion between the two groups. Oxygen arterial pressure (PaO2) of patients in the Arndt group was significantly higher than L-DLT (154±46 vs 105±52 mmHg; P<0.05). Quality of lung collapse and surgical field exposure in the Arndt group was significantly better than L-DLT (effective rate 100 vs 90%; P<0.05). Duration of surgery and anesthesia were significantly shorter in the Arndt group (2.4±1.7 vs 3.1±1.8 and 2.8±1.9 vs 3.8±1.8 h, respectively; P<0.05). Incidence of hoarseness of voice and incidence and severity of throat pain at the post-anesthesia care unit and 12, 24, 48, and 72 h after surgery were significantly lower in the Arndt group (P<0.05). Findings suggested that Arndt-endobronchial blocker combined with LMA can serve as a promising alternative for morbidly obese patients in OLV in thoracic surgery.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Obesidade Mórbida/cirurgia , Máscaras Laríngeas/normas , Ventilação Monopulmonar/instrumentação , Intubação Intratraqueal/instrumentação , Atelectasia Pulmonar , Fatores de Tempo , Método Duplo-Cego , Estudos Prospectivos , Resultado do Tratamento , Desenho de Equipamento , Ventilação Monopulmonar/métodos , Duração da Cirurgia , Intubação Intratraqueal/métodos
3.
Anesthesia and Pain Medicine ; : 353-356, 2011.
Artigo em Inglês | WPRIM | ID: wpr-69748

RESUMO

In thoracic surgery, functional isolation of the lungs can be accomplished by several methods. However, for patients with tracheal stenosis, only limited choices are available to achieve one-lung ventilation (OLV) because of the difficulties posed by the stenotic trachea. In our patient, the narrowest site in the trachea was as small as 9.3 mm in diameter, and therefore a 28 Fr double-lumen endotracheal tube (DLT) or a Univent tube (inner diameter [ID] 6.0 mm) could not be inserted into the trachea. Recently, 7 and 9 Fr Arndt endobronchial blockers (AEB) used in adults could not even be used in our patient. Here we report a case of successful OLV that was performed using a pediatric wire-guided AEB and a small diameter single lumen endotracheal tube (SLT). We believe that this pediatric AEB is a safer and more effective option for achieving OLV in adult patients with tracheal stenosis.


Assuntos
Adulto , Humanos , Pulmão , Ventilação Monopulmonar , Cirurgia Torácica , Traqueia , Estenose Traqueal
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA