Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Arch. cardiol. Méx ; 92(3): 342-348, jul.-sep. 2022. tab, graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1393829

RESUMO

Resumen Objetivos: Determinar si los pacientes con cardiopatía chagásica (CCh) presentaron choques apropiados del desfibrilador automático implantable (DAI) de manera más precoz que los pacientes con cardiopatía isquémica (CI). Métodos: Estudio de cohorte retrospectivo que incluyó los pacientes con CCh y CI en quienes se implantó un DAI entre los años 2009 y 2018 en un hospital de alta complejidad. El seguimiento se realizó hasta los 36 meses, evaluándose el momento del primer choque apropiado del dispositivo. Resultados: Se incluyeron 64 pacientes, 20 con CCh y 44 con CI. Se observó que una mayor proporción de pacientes con CCh presentaron choques apropiados durante el primer año (hazard ratio [HR]: 8.4; intervalo de confianza del 95% [IC95%]: 2.09-34.02; p = 0.0027) y a 3 años (HR: 4.61; IC95%: 1.51-14.07; p = 0.0072). El 100% de la población con CCh e implante del DAI como prevención secundaria de muerte súbita presentaron choques apropiados durante los primeros 26 meses de seguimiento. Conclusiones: Los pacientes con CCh presentaron choques apropiados del DAI de manera más precoz que los pacientes con CI. Todos los pacientes con CCh y DAI como prevención secundaria presentaron choques apropiados, representando una población de mayor riesgo. Esta información apoya la indicación del DAI en estos pacientes a pesar de la escasa evidencia en ensayos aleatorizados.


Abstract Objetives: To assess if patients with Chagasic heart disease (CHD) received effective automatic implantable defibrillator (AID) shocks earlier than patients with ischemic heart disease (IHD). Methods: Retrospective cohort of patients with CHD and IHD who received an implantable cardioverter defibrillator (ICD) between 2009 and 2018, in a tertiary hospital. We evaluated the time between the implant of ICD and the first effective shock in patients with CHD and compared it with the IHD control population. Results: We included a total of 64 patients, 20 with CHD and 44 with IHD. CHD patients presented earlier an effective shock than patients with IHD during the first year (hazard ratio [HR]: 8.4; 95% confidence interval [95% CI]: 2.09-34.02; p = 0.0027), and at three years (HR: 4.61; 95% CI: 1.51-14.07; p = 0.0072). 100% of CHD patients who received the ICD as secondary prevention of sudden cardiac death presented an effective shock during the first 26 months of follow-up. Conclusions: Patients with CHD received effective ICD shocks earlier than the IHD patients. All patients with CHD and ICD as secondary prevention had an appropriate ICD shock at short term, representing the highest risk population, and supporting the indication of the device in a setting where randomized clinical trials are lacking.

2.
Ann Card Anaesth ; 2015 Oct; 18(4): 599-602
Artigo em Inglês | IMSEAR | ID: sea-165277

RESUMO

The indication of pacemaker/AICD removal are numerous. Serious complication can occur during their removal, severe tricuspid regurgitation is one of the complication. The occurrence of PFO is not uncommon among adult population. Shunting across PFO in most circumstance is negligible, but in some necessitates closure due to hypoxemia. We report a case of 62 year old man, while undergoing AICD removal, had an emergency sternotomy for cardiac tamponade. Postoperatively, he experienced profound hypoxemia refractory to oxygen therapy. Transthoracic Echocardiogram was performed to rule out intracardiac shunts at an early stage, but it was difficult to obtain an good imaging windows poststernotomy. A small pulmonary emboli was noted on CTPA, but was not sufficient to account for the level of hypoxemia and did not resolve with anticoagulation. Transesophageal echocardiogram showed flail septal tricuspid valve with severe TR and bidirectional shunt through large PFO. Patient was posted for surgery, tricuspid valve was replaced and PFO surgically closed. Subsequently, patient recovered well ad was discharged to home. Cause of hypoxemia might be due to respiratory or cardiac dysfunction. But for hypoxemia refractory to oxygen therapy, transoesophageal echocardiogram should be always considered and performed early as an diagnostic tool in post cardiac surgical patients.

3.
Arch. cardiol. Méx ; 81(2): 93-99, abr.-jun. 2011. ilus, tab
Artigo em Espanhol | LILACS | ID: lil-632027

RESUMO

Introducción: Actualmente, el monitoreo de algunos dispositivos cardiacos implantables como los marcapasos y el desfibrilador automático, así como la terapia de resincronización cardiaca asociada con desfibrilador automático implantable, son los que se utilizan con mayor frecuencia y el seguimiento de los mismos se puede llevar a cabo por vía satelital; por ello su revisión y monitoreo ha incrementado las visitas presenciales en las clínicas de marcapasos y desfibriladores. A continuación se informa la experiencia de la monitorización vía satélite de dichos dispositivos en un centro hospitalario de tercer nivel. Métodos: Se seleccionaron 18 pacientes de la Clínica de Marcapasos del Servicio de Electro-fisiología y Estimulación Cardiaca de la Unidad Médica de Alta Especialidad del Hospital de Especialidades Dr. Antonio Fraga Mouret, Centro Médico Nacional La Raza del Instituto Mexicano del Seguro Social a los cuales se les había implantado un desfibrilador o resincronizador con capacidad de vigilancia remota vía satélite (Home Monitoring BIOTRONIK, Alemania), de marzo del 2006 a marzo del 2009. Resultados: Como reportes, se obtuvieron 4980 transmisiones y 149 alertas por sucesos registrados, de los cuales 50 fueron de fibrilación ventricular, 14 de taquicardia ventricular, extrasístoles ventriculares frecuentes superadas por el rango permitido en una hora fueron 25, fibrilación auricular en 11. Conclusión: El sistema de vigilancia remota vía satélite es una herramienta de diagnóstico confiable, que permite una detección temprana de las principales arritmias que ocurren en los sujetos con dispositivos cardiacos implantables.


Introduction: The implantable cardiac devices like regular pacemaker, cardiac resynchronization therapy (CRT) automatic implantable defibrillators (ICD) and CRT associate with ICD (CRT-D) are now being used frequently. Patient visits to pacemaker and ICD clinics for review and monitoring, has increases significantly. We present the experience of monitoring via satellite of patients with implantable cardiac devices in Mexico. Methods: Eighteen patients were selected from the arrhythmia Service Cardiac Electrophysiology and Stimulation of High Specialty Medical Unit (UMAE) of Specialties Hospital Dr. Antonio Fraga Mouret. National Medical Center (NMC) La Raza Mexican Social Security Institute (IMSS), who had a device (CRT, ICD y CRT-D) that is able to send information through the BIOTRONIK Home Monitoring system, from March 2006, to March 2009. Results: We obtained 4,980 transmissions as reports and 149 alerts recorded events, of which 50 were in ventricular fibrillation, 14 in ventricular tachycardia, frequent ventricular extra systoles exceeded by the range allowed in one hour were 25, electrograms default 26; and atrial fibrillation at 11. Conclusions: The monitoring system via satellite is reliable and useful diagnostic tool, which permits early detection, opportune treatment and effective monitoring of implantable cardiac devices.


Assuntos
Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Arritmias Cardíacas/terapia , Dispositivos de Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Telemetria , Seguimentos
4.
Av. cardiol ; 30(4): 408-411, dic. 2010. ilus, graf
Artigo em Espanhol | LILACS | ID: lil-607785

RESUMO

Se presenta el caso de un paciente que ingresa a nuestro servicio presentando terapias inapropiadas e infección del bolsillo, posterior al implante de un desfibrilador automático implantable con un electrodo Sprint Fidelis 6949 en estado de alerta del fabricante...


A case of a patient who was admitted to our department with inappropriate therapies and infection of the pocket, after implantation of an implantable defibrillator with a Sprint Fidelis 6949 electrode on alert of the manufacturer...


Assuntos
Humanos , Masculino , Idoso , Desfibriladores Implantáveis/efeitos adversos , Infecções Cardiovasculares/complicações , Infecções Cardiovasculares/etiologia , Complicações Pós-Operatórias , Cirurgia Torácica
5.
Rev. argent. cardiol ; 77(3): 224-226, mayo-jun. 2009. ilus
Artigo em Espanhol | LILACS | ID: lil-634087

RESUMO

La vena cava superior izquierda persistente (VCSIP) es la anomalía congénita venosa del tórax más frecuente. Se encuentra en el 0,3% de la población general y en el 5-10% de los pacientes con cardiopatías congénitas. Generalmente evoluciona en forma asintomática y no genera trastornos hemodinámicos, pero su reconocimiento es importante, ya que puede dificultar la introducción de catéteres para mediciones hemodinámicas, los implantes de marcapasos cardíacos (MCP) y de cardiodesfibriladores automáticos implantables (CDAI), especialmente cuando se utiliza la vía cefálica o la subclavia izquierda. En el caso clínico que se presenta se efectuó el implante de un CDAI bicameral vía VCSIP, descubierta durante el procedimiento. Asimismo, se muestran las características de esta variedad anatómica mediante tomografía cardíaca computarizada de 64 cortes (TCC64).


Persistent left superior vena cava (PLSVC) is the most common congenital defect in the thoracic venous system, with an incidence of 0.3% in the general population and of 5-10% in patients with congenital heart disease. This asymptomatic condition does not produce hemodynamic impairment; however, it should be recognized as its presence poses technical challenges in the introduction of catheters for hemodynamic measurements and for placement of pacemakers (PMs) and implantable cardioverter defibrillators (ICD) via the cephalic vein or the left suclavian vein. In the present case report we describe the implantation of a dual-chamber ICD through a PLSVC discovered during the procedure. In addition, images from cardiac 64-row multidetector computed tomography (64-row CT) show the anatomic features of this variety.

6.
Gac. méd. Méx ; 141(2): 89-98, mar.-abr. 2005. ilus, tab
Artigo em Espanhol | LILACS | ID: lil-632061

RESUMO

La muerte súbita se define como aquella que ocurre antes de una hora de la aparición de los síntomas. Es una condición grave que en diversos países supone un problema de salud pública y que en México implica entre 33 y 53 mil muertes anuales, en su mayoría ligadas a enfermedad isquémica del corazón. La causa primordial de la muerte súbita son las arritmias ventriculares graves, sin embargo determinar qué sujetos son susceptibles de tener un episodio arrítmico es complejo y por ello la relación costo efectividad de las medidas de estratificación de riesgo suele ser mala. En el presente trabajo se revisan las diferentes estrategias para determinar el riesgo de muerte súbita. Las estrategias para el tratamiento oportuno de la muerte súbita relativas a la población general utilizadas en diversos países tienen impactos variables en la supervivencia, sin embargo, en las poblaciones seleccionadas con alto riesgo de padecer un evento arrítmico ventricular, la mejor terapia disponible actualmente es el desfibrilador automático implantable, aunque en el trabajo se discuten otras opciones de tratamiento. En nuestro país es necesario hacer un importante esfuerzo de detección prevención y tratamiento oportuno para limitar las consecuencia de este problema.


Sudden death is defined as the death occurring less than one hour before the onset of the patient's symptoms. It is a severe condition considered a public health issue in several countries and in ours, it accounts for 33 000 to 53 000 annual deaths mainly related to ischemic heart disease. The main cause of sudden death are severe ventricular arrhythmias, but determining what patients are at risk for such an episode is complex, that is why risk stratification is usually a low cost-effective intervention. In the present study, we describe different sudden death risk stratification strategies. Different sudden death treatment strategies regarding general population have different success rates in different countries, nevertheless, among select high risk populations; the best therapy currently available is the automatic implantable cardioverter defibrillator. We also discuss other treatment options. In Mexico it is deemed necessary to do an important effort for the early detection, prevention and treatment of sudden death in order to limit the consequences of this problem.


Assuntos
Humanos , Morte Súbita Cardíaca/etiologia , Ensaios Clínicos como Assunto , Morte Súbita Cardíaca/epidemiologia , Eletrocardiografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA