Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Adicionar filtros








Intervalo de ano
1.
Chinese Acupuncture & Moxibustion ; (12): 43-47, 2020.
Artigo em Chinês | WPRIM | ID: wpr-781771

RESUMO

OBJECTIVE@#To calculate the imbalance degree (IBD) of left-right meridian (IBD-LRM), IBD of exterior-interior meridian (IBD-EIM) and IBD of hand-foot meridians (IBD-HFM) of impedance in extracellular fluid of cells in twelve meridians of healthy subjects, so as to provide foundation for meridian diagnosis.@*METHODS@#A total of 31 healthy volunteers were enrolled and bioelectrical impedance spectroscopy (BIS) was applied. The constant current (from 1 to 100 kHz, 200 μA) was connected into the bilateral twelve meridians through two excitation electrodes with a distance of 10 cm. Two measuring electrodes, with an interval of 5 cm, were set in between the two excitation electrodes to collect the voltage amplitude and phase. The Cole-Cole curve fitting was used to calculate the impedance of extracellular fluid of cells in the twelve meridians; the IBD-LRM, IBD-EIM and IBD-HFM as well as their absolute values were calculated.@*RESULTS@#The impedance of extracellular fluid in the left side was higher than that in right side in the large intestine meridian, the small intestine meridian and the bladder meridian (<0.05, <0.01). The mean value of IBD-LRM of extracellular fluid was (4.0±1.4) %; the mean value of absolute value of IBD-LRM was (15.0±1.1) %; the maximum absolute value of IBD-LRM was the bladder meridian. The mean value of IBD-EIM was (3.3±1.0) %; the mean value of absolute value of IBD-EIM was (17.9±1.6) %; the maximum absolute value of IBD-EIM was the bladder meridian and the kidney meridian. The impedance of extracellular fluid of hand meridian, hand meridian and hand meridian were lower than those of foot meridians. The mean value of IBD-HFM was (-2.6±1.1) %; the mean value of absolute value of IBD-HFM was (19.7±1.7) %; the maximum absolute value of IBD-HFM was meridian; the imbalance of meridians was greater than meridians. There were significant differences in impedance of extracellular fluid between left and right and between hands and feet (<0.05, <0.01).@*CONCLUSION@#The extracellular fluid of left-right meridians of healthy subjects is different, but the absolute value of IBD is low; the mean value of exterior meridian and interior meridian is very close, and the absolute value of IBD is medium; the impedance of the foot meridians are greater than the hand meridians, and the absolute value of IBD is relatively high.


Assuntos
Humanos , Pontos de Acupuntura , Impedância Elétrica , Líquido Extracelular , Voluntários Saudáveis , Meridianos
2.
Annals of Rehabilitation Medicine ; : 687-693, 2011.
Artigo em Inglês | WPRIM | ID: wpr-16461

RESUMO

OBJECTIVE: To investigate the usefulness of bioimpedance measurement for predicting the treatment outcome in breast cancer related lymphedema (BCRL) patients. METHOD: Unilateral BCRL patients who received complex decongestive therapy (CDT) for 2 weeks (5 days per week) were enrolled in this study. We measured the ratio of extracellular fluid (ECF) volume by using bioelectrical impedance spectroscopy (BIS), and single frequency bioimpedance analysis (SFBIA) at a 5 kHz frequency before treatment. Arm circumferences were measured at 10 cm above and below the elbow before and after treatment. We also investigated whether there is correlation between ECF ratio and SFBIA ratio with the change of arm circumference after CDT. RESULTS: A total of 73 patients were enrolled in this study. The higher ECF ratio was significantly correlated with higher reduction of arm circumference at both above and below the elbow after treatment, but the higher SFBIA ratio was correlated only with the higher reduction of arm circumference below the elbow. CONCLUSION: These results show that ECF volume measurements and SFBIA before treatment are useful tools for predicting the outcome of patients with lymphedema. We concluded that ECF volume measure can be used as a screening tool for predicting treatment outcome of BCRL patients.


Assuntos
Humanos , Braço , Mama , Neoplasias da Mama , Cotovelo , Impedância Elétrica , Líquido Extracelular , Linfedema , Programas de Rastreamento , Análise Espectral , Resultado do Tratamento
3.
Japanese Journal of Physical Fitness and Sports Medicine ; : 87-97, 2005.
Artigo em Inglês | WPRIM | ID: wpr-362324

RESUMO

The purpose of this study was to examine the relation between body composition and athletic performance of long distance relay runners in a four week weight reduction program. Six male collegiate runners, aged 19.0 ± 0.9 years, participated in this study. Body water content and fat free mass (FFM) were measured by bioelectrical impedance spectroscopy.The weight loss by 4.1% of the initial body weight consisted of decreases in FFM and fat mass (54% and 46% respectively). Percentage of body fat did not change significantly by the end of the fourth week. The total body water (TBW) loss comprised of intracellular water (ICW) and extracellular water (ECW) at the end of the fourth week, and TBW loss and FFM loss were nearly the same values. Isokinetic muscular strength of right thigh, maximal oxygen intake (VO<sub>2</sub>max) and total treadmill running time (maximal workout time) measured did not show any significant change. These results indicate (1) half of the weight loss consisted of decrease in FFM, (2) TBW loss was due to the reduction of ICW and ECW, (3) the content of FFM loss was considered to be body water, and (4) there was no impact on muscular strength of right thigh, VO<sub>2</sub>max or maximal workout time.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA