Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Adicionar filtros








Intervalo de ano
1.
Journal of Pharmaceutical Analysis ; (6): 253-262, 2020.
Artigo em Chinês | WPRIM | ID: wpr-824003

RESUMO

In traditional Chinese medicine herbs (TCM), including Radix Salviae Miltiorrhizae (Danshen), Radix Puerariae Lobatae (Gegen), Radix Angelicae Sinensis (Danggui), and Rhizoma Chuanxiong (Chuanxiong) are widely used for the prevention and treatment of cardiovascular diseases and also often co-administered with Western drugs as a part of integrative medicine practice. Carboxylesterase 1 (CES1) plays a pivotal role in the metabolisms of pro-drugs. Since (S)-2-(2-(6-dimethylamino)-benzothiazole)-4,5-dihydro-thiazole-4-carboxylate (NLMe) has recently been identified by us as a selective CES1 bioluminescent sensor, we developed a rapid method using this substrate for the direct measurement of CES1 activity in rats. This bioluminescence assay was applied to determine CES1 activity in rat tissues after a two-week oral administration of each of the four herbs noted above. The results demonstrated the presence of CES1 enzyme in rat blood and all tested tissues with much higher enzyme activity in the blood, liver, kidney and heart than that in the small intestine, spleen, lung, pancreas, brain and stomach. In addition, the four herbs showed tissue-specific effects on rat CES1 expression. Based on the CES1 biodistribution and its changes after treatment in rats, the possibility that Danshen, Gegen and Danggui might alter CES1 ac-tivities in human blood and kidney should be considered. In summary, a selective and sensitive biolu-minescence assay was developed to rapidly evaluate CES1 activity and the effects of orally administered TCMs in rats.

2.
Chinese Journal of Infection Control ; (4): 260-263, 2018.
Artigo em Chinês | WPRIM | ID: wpr-701605

RESUMO

Objective To investigate the cleanliness status of personal digital assistant(PDA)surfaces, and observe the effect of disposable antiseptic wipes on the cleaning and disinfection of PDA surface.Methods From January to March 2016, 83 daily used handheld PDA in 50 clinical wards of a hospital were as control group, 83 PDA disinfected by disposable antiseptic wipes(CaviWipes)and used in the same environment of the ward at the same time were selected as the intervention group, cleanliness status of PDA surfaces of two groups were detected by adenosine triphosphate(ATP)bioluminescence assay.Results Taken a cut-off value≤100 RLU/100 cm2 as qualified standard of cleanliness, none of PDA in control group was qualified with ATP bioluminescence reading ranged from 189 to 3 379 RLU;after disinfection with CaviWipes, the qualified rate of intervention group was 90.4%(n=75), ATP detection value of PDA surface in all departments were significantly lower than control group(median:[18-28] RLU vs[290-339]RLU, all P<0.05).Conclusion Microbial contamination on PDA used in hospital wards is common, antiseptic wipes containing quaternary ammonium salt can be used for cleaning and disinfecting surface of PDA.

3.
Chinese Journal of Infection Control ; (4): 825-828, 2017.
Artigo em Chinês | WPRIM | ID: wpr-613100

RESUMO

Objective To explore the cleaning status and cleaning quality of dental handpieces in various types of medical institutions in Suzhou City.Methods On October 26-31, 2015, dental clinics in the whole city were sampled according to cross-sectional survey and proportional sampling method, the cleaning quality of dental handpieces in each clinic was detected by ATP bioluminescence assay.Results 72 medical institutions, 201 handpieces, 402 samples in 10 administrative regions of the city were sampled, 42 samples was unqualified, unqualified rate was 10.45%, unqualified rate of cleaning of dental handpiece surface was higher than waterline of dental handpiece(17.91% vs 2.99%, P<0.05).Cleaning quality of dental handpieces in different grades of medical institutions was different(P<0.05), tertiary medical institutions were all ualified, medical institutions without grade was 14.45%.According to the classification based on name of different medical institutions, cleaning quality of handpieces was statistically significant(P<0.05), cleaning efficacy of dental handpieces in department of stomatology of public hospitals was best(unqualified rate was 4.31%), while private dental clinics had the worst cleaning efficacy(unqualified rate was 13.81%).Conclusion Education and training of dental handpieces cleaning in the whole city should be strengthened, especially the management of cleaning of dental handpieces in low grade and private dental clinics.

4.
Journal of Modern Laboratory Medicine ; (4): 89-91,95, 2017.
Artigo em Chinês | WPRIM | ID: wpr-663442

RESUMO

Objective To investigate the value of adenosine triphosphate(ATP)bioluminescence assay for assessing object surface contamination degree in intensive care unit(ICU).Methods 30 groups of high frequency contact object(including ventilator panel,bedside table and computer keyboard)in ICU from January to December 2016 were enrolled for the study. Each object was sampled and evaluated before and after disinfection,and their surface was divided into two areas,whose sur-face contamination degree was evaluated by ATP bioluminescence assay and bacterial culture method that were classified as ATP group and control group.The fluorescence detection value and colony number were compared between two groups be-fore and after disinfection.The correlation between the fluorescence detection value and colony number was analyzed by Pearson correlation in the same sample,and the Kappa consistency test was used for the qualification rates of two detections. Results ①The fluorescence detection value and colony number of ventilator panel,bedside table and computer keyboard af-ter disinfection in two groups were significantly lower than that before disinfection(t=8.107~26.393,all P<0.05).②Pearson analysis result showed that both before and after disinfection,the fluorescence detection value had no significant cor-relation with colony number of ventilator panel,bedside table and computer keyboard(r=0.199~0.338,all P>0.05).③There were no significant differences in the qualification rate between two groups of ventilator panel,bedside table and com-puter keyboard before and after disinfection(χ2=0.000~1.404,all P>0.05).The qualification rate before the disinfection of ATP group and control group were 0 and 8.9%,and that after disinfection were 86.7% and 91.1%,whose Kappa consis-tency test result showed that the Kappa value was 0.776(95%CI:0.575~0.978)>0.75,so the consistency was quite sat-isfied.Conclusion ATP bioluminescence assay could be used as a rapid and handy preliminary screening to assist bacterial culture method to evaluate the object surface contamination in ICU,and the result was satisfactory and it would be worthy of clinical application.

5.
Chinese Journal of Infection Control ; (4): 52-55, 2016.
Artigo em Chinês | WPRIM | ID: wpr-491770

RESUMO

Objective To investigate cleanliness of hospital environmental object surfaces and hands of health care workers(HCWs).Methods The adenosine triphosphate (ATP)bioluminescence assay was used to detect object surfaces and hands of HCWs in a hospital,on-the-spot intervention was conducted.Results The qualified rates of hospital environmental object surfaces and ventilator-relevant object surfaces were 58.14% (200/344)and 69.88%(116/166)respectively,the qualified rate of ventilator tracheal intubation site was low (29.17%);the qualified rate of telephone surfaces was the lowest (27.27%).The qualified rates of ventilator-relevant object surfaces used con-tinuously for ≥48h and <48 h were 56.70%(55/97)and 88.41 %(61/69)respectively,there was significant differ-ence between the two(χ2 =19.26,P <0.01).The qualified rates of HCWs’hands before and after intervention were 34.18% and 85.58% respectively,relative light unit (RLU)values were (1 033.46±106.20)and (80.46±10.68) respectively,the qualified rates and RLU before and after intervention were both significantly different (both P <0.01).Conclusion Contamination of object surfaces and hands’of HCWs in hospital dynamic environment is seri-ous,ATP bioluminescence detection and on-the-spot intervention is helpful for improving cleanliness of hospital en-vironment object surfaces and HCWs’compliance to hand hygiene.

6.
International Journal of Laboratory Medicine ; (12): 1961-1962, 2015.
Artigo em Chinês | WPRIM | ID: wpr-474579

RESUMO

Objective To summarize the application of ATP bioluminescence assay in surveillance of terminal disinfection of effects ,so as to provide the basis for intervention of disinfected effects .Methods ATP bioluminescence assay were employed to randomly test the surfaces of operating objects in therapeutic rooms and beside tables in wards ,total 144 object surfaces ,of each clinical departments in the whole hospital .The values of ATP bioluminescence assay were read on‐site ,0-250 RLU was recognized as qualification ,while disqualification when >250 RLU .The disqualified object surfaces were performed on‐site intervention that all of them were re‐disinfected ,the results were compared .Results Both the surfaces of operating objects and beside tables were dis‐qualified before disinfection ,and the values of ATP bioluminescence assay were 780 ± 10 .34 RL and 853 ± 13 .29 RLU respectively . The pass rates of ATP bioluminescence assay was 61 .97% of operating surfaces and 79 .45% of beside table surfaces the first dis‐infection .The disqualified sites were retested following on‐site intervention .The values of ATP bioluminescence assay were 431 .02 ± 0 .53 before intervention and 1 .43 ± 0 .59 after intervention ,and the difference was statistically significant .Conclusion ATP bi‐oluminescence assay can get more immediately ,simple and timesaving in evaluating the effect of disinfection and estimate the effi‐ciency of disinfection timely ,which can also provide the scientific basis on on‐site intervention so as to improve the execution power of hospital infection management .

7.
Chinese Journal of Infection Control ; (4): 849-850,853, 2015.
Artigo em Chinês | WPRIM | ID: wpr-603080

RESUMO

Objective To detect bacterial content on surface of mobile phones of health care workers (HCWs)by adenosine triphosphate (ATP )bioluminescence assay.Methods HCWs in departments of internal medicine,surgery, medical laboratory,and administration were randomly selected,50 in each department,field detection on bacterial content on surface of mobile phones of HCWs was conducted,the relevant data were recorded.Results A total of 200 mobile phones were detected,33 mobile phone surface were qualified,the qualified rate was 16.50%.Qualified rate of mobile phone surface of HCWs in different departments as well as mobile phone disinfected by different modes were different(χ2 =13.46,10.24,respectively,both P 0.05).Conclusion The qualified rate of bacterial content on surface of HCWs’mobile phone is low,the awareness of hand hygiene of HCWs should be strengthened,regular cleaning and disinfection on the mo-bile phone can effectively reduce bacteria on the mobile phone surface.

8.
Chinese Journal of Behavioral Medicine and Brain Science ; (12): 886-888, 2013.
Artigo em Chinês | WPRIM | ID: wpr-441958

RESUMO

Objective To study the relationship between CCAAT/enhancer-binding proteins (C/EBPs) and circadian genes expression in mammals.Methods C/EBP-a 240,280,650,1300 and Rev erb-a promoter-luciferase reporter gene expression vectors were set up,as well as the corresponding report gene stable transfection cell lines were established.The intensity and/or rhythm of report gene expression were observed by testing the biological fluorescent.Results The transcription factor CLOCK/BMAL1 heterodimer activated C/EBP-a via a conserved E-box element in its promoter,and the latter showed circadian oscillation which was E-box dependent.On the other hand,C/EBP-a suppressed Rev-erba transcription.Moreover,GR signaling,a known resetting signal for circadian clock,suppressed C/EBP-a transcription.Conclusion The data highlight the reciprocal feedback regulation between a key transcription factor C/EBP-a and the timing mechanism in cells.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA