Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Adicionar filtros








Intervalo de ano
1.
Rev. cuba. oftalmol ; 35(2)jun. 2022.
Artigo em Espanhol | LILACS, CUMED | ID: biblio-1441717

RESUMO

Objetivo: Comparar la biometría ocular entre adultos jóvenes chinos y cubanos pertenecientes al sector salud. Métodos: Estudio observacional descriptivo de corte transversal en 30 chinos y 30 cubanos, residentes de las diferentes especialidades médicas, que acudieron al Instituto Cubano de Oftalmología "Ramón Pando Ferrer" entre septiembre de 2016 y septiembre de 2017. Las variables estudiadas fueron: longitud axial, profundidad de cámara anterior, y diámetro corneal horizontal. Se realizó biometría de no contacto con IOLMaster 500 (Carl Zeiss) en ambos ojos. Resultados: La edad media fue 24,9 años y 25,9 años en cubanos y chinos respetivamente. Los resultados biométricos promedio de ambos ojos para cubanos/chinos fueron: longitud axial 24,10 mm/24,60 mm; amplitud de cámara anterior 3,56 mm/3,46 mm; y diámetro corneal horizontal 11,80 mm/11,60 mm, sin diferencias estadísticamente significativas. El 60 de los ojos chinos fueron largos mientras que en los cubanos fue el 45 . Se reportaron dos ojos chinos con cámara anterior estrecha y el diámetro corneal horizontal fue normal en el 100 por ciento. Conclusiones: Los chinos exhibieron ojos de mayor longitud axial, menor amplitud de cámara anterior y menor diámetro corneal horizontal que los cubanos aunque las diferencias no fueron estadísticamente significativas.(AU)


Objective: To compare ocular biometry between Chinese and Cuban young adults belonging to the health sector. Methods: Descriptive observational cross-sectional study in 30 Chinese and 30 Cubans, residents of different medical specialties, who attended the Cuban Institute of Ophthalmology "Ramón Pando Ferrer" between September 2016 and September 2017. The variables studied were: axial length, anterior chamber depth, and horizontal corneal diameter. Non-contact biometry was performed with IOLMaster 500 (Carl Zeiss) in both eyes. Results: The average age was 24.9 years and 25.9 years in Cuban and Chinese patients respectively. The average biometric results of both eyes for Cuban/Chinese eyes were: axial length 24.10 mm/24.60 mm; anterior chamber width 3.56 mm/3.46 mm; and horizontal corneal diameter 11.80 mm/11.60 mm, with no statistically significant differences. Sixty percent of the Chinese eyes were long, while 45 percent of the Cuban eyes were long. Two Chinese eyes were reported with narrow anterior chamber and horizontal corneal diameter was normal in a 100 percent of them. Conclusions: Chinese exhibited eyes of greater axial length, smaller anterior chamber width and smaller horizontal corneal diameter than Cubans although the differences were not statistically significant(AU)


Assuntos
Humanos , Adulto , Biometria/métodos
2.
Arq. bras. med. vet. zootec ; 66(1): 121-128, fev. 2014. ilus, tab
Artigo em Português | LILACS | ID: lil-704015

RESUMO

Este trabalho objetivou descrever e comparar as alterações ultrassonográficas encontradas em bulbos oculares de cães submetidos à facoemulsificação, com ou sem implante de lente intraocular (LIO), no intuito de auxiliar no diagnóstico de alterações decorrentes da cirurgia e do implante da LIO, bem como sua correspondência com alterações clínicas. Dezenove cães portadores de catarata (21 olhos) foram submetidos ao procedimento de facoemulsificação e avaliados no pós-operatório tardio, aos cinco anos de evolução. Constituíram-se três grupos experimentais: afácicos (CA), formados por 11 cães; pseudofácicos (PP), com implante de duas LIOs em piggyback (n=5); e pseudofácicos (PL), com implante de uma LIO veterinária (n=5). Após exame oftálmico, todos foram submetidos ao exame ultrassonográfico, sob anestesia tópica, com transdutor linear multifrequencial de 10MHz; adicionalmente foram avaliadas medidas biométricas dos bulbos do olho. As principais alterações observadas foram: luxação da LIO, descolamento de retina, hialose asteroide e degeneração vítrea. O exame ultrassonográfico mostrou-se como excelente ferramenta diagnóstica e possibilitou a confirmação e a classificação dessas alterações. Na biometria ocular, pelas medidas entre o corpo ciliar e a câmara vítrea, o implante em piggyback resultou em redução destas em relação aos demais procedimentos instituídos, não havendo diferença ente o comprimento axial e a câmara anterior.


This study aimed to describe and compare the ultrasonographic alterations in dogs' eyes submitted to facectomy with or without intraocular lens implant (IOL), to assist in the diagnosis of possible alterations related to the surgical procedure and IOL implantation. Nineteen dogs with cataract (21 eyes) were submitted to phacoemulsification and late postoperative evaluation (at five years). The animals were initially submitted to complete ophthalmological exams which preceded the sonogram. Dogs were divided in three groups: (CA) aphakic dogs (n= 11); (PP) pseudophakic dogs with implantation of two IOLs in piggyback (n=5) and (PL) pseudophakic dogs with implantation of a veterinary IOL (n = 5). The ultrasound was carried under the administration of a topic local anesthetic, with a multi frequency linear transducer of 10 MHz. Biometric eye measurements were also performed. The clinical alterations observed were IOL dislocation, retinal detachment, asteroid hyalosis, and vitreous degeneration. Ultrasound examination was an excellent diagnostic tool, as it was possible to confirm and classify these changes. The piggyback implant reduced the measurements between the ciliary body and the vitreous chamber obtained from the ocular biometry when compared to other usual procedures, with no difference between the axial length and the anterior chamber.


Assuntos
Animais , Lentes Intraoculares , Olho/anatomia & histologia , Ultrassonografia , Cães/classificação , Oftalmologia/métodos
3.
Pesqui. vet. bras ; 29(4): 286-290, Apr. 2009. ilus, tab
Artigo em Português | LILACS | ID: lil-519575

RESUMO

Avaliou-se 31 cães saudáveis, sem raça definida, sendo 10 machos e 21 fêmeas, com 8 meses a 7 anos de idade e peso de1,5-28 kg. Inicialmente foram mensurados os diâmetros fronto-occiptal (DFO) e bizigomático (DBZ) do crânio com o auxílio de um paquímetro. A ultra-sonografia transpalpebral em modo-B foi realizada para mensurar as estruturas do bulbo ocular, conforme se segue: D1- espessura da córnea; D2- distância entre o ponto central da imagem da córnea e a da cápsula anterior do cristalino (câmara anterior); D3- distância entre o ponto central da imagem da córnea e a da cápsula posterior do cristalino; D4- espessura do cristalino, que corresponde a distância entre a imagem da cápsula anterior e a cápsula posterior do cristalino; D5- diâmetro do cristalino, distância entre as imagens dos pólos do cristalino; D6- área do cristalino; D7- câmara vítrea, distância entre a imagem da cápsula posterior do cristalino e a retina; D8- distância entre a cápsula anterior do cristalino e a retina; D9- distância entre a imagem da córnea e a retina. Com exceção da D4, houve efeito dos DFO e DBZ sobre as medidas das estruturas internas do BO. A análise de regressão linear entre as medidas das estruturas do bulbo ocular e os DFO e DBZ foram significativas para D1, D2, D3, D4, D5, D6, D7, D8 e D9.


In the experiment 31 healthy mongrel dogs, 8 months to 7 years of age, were used, 10 males and 21 females, weighing 1.5-28 kg. Initially, fronto-occipetal (FOD) and bizigomatic (BZD) diameters were measured using a caliper. The ophthalmologic transpalpebral B-mode ultrasonography (US) was performed to measure the ocular bulbi structures, as follows: The cornea thickness (D1), distance between cornea and anterior lens capsule (D2), distance between cornea and posterior lens capsule (D3), lens thickness (D4), lens diameter (D5), lens area (D6), distance between posterior lens capsule and retina (D7), distance between anterior lens capsule and retina (D8), and the distance between cornea and retina (D9). Except for D4, there were effect of FOD and BZD on the measures of the internal structures of BO. The Lineal Regression Analysis between the measures of the internal oculars structures and DFO and DBZ were significant for D1, D2, D3, D4, D5, D6, D7, D8 and D9.


Assuntos
Animais , Biometria/métodos , Crânio/anatomia & histologia , Cães , Segmento Anterior do Olho/anatomia & histologia , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA