Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Adicionar filtros








Intervalo de ano
1.
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery ; (12): 1323-1328, 2023.
Artigo em Chinês | WPRIM | ID: wpr-996974

RESUMO

@#Objective    To study the hemocompatibility of bioprosthetic heart valve materials respectively based on glutaraldehyde and non-glutaraldehyde treatment. Methods    Fresh bovine pericardium was treated with glutaraldehyde or non-glutaraldehyde after adipose tissue was removed. To evaluate the hemocompatibility of the two bioprosthetic heart valve materials, hemolysis test, in vitro fibrinogen adsorption experiment, platelet adhesion experiment, thrombin-antithrombin complex (TAT) test, complement activation assay and ex vivo circulation experiment were performed. Results    The hemolysis test results demonstrated that both of the materials showed hemolytic rates lower than 5%. The results of TAT test and complement activation assay showed no statistical differences among the two materials and the blank control group. Compared to the bioprosthetic heart valve materials with glutaraldehyde-based treatment, the materials with non-glutaraldehyde-based treatment showed significantly decreased fibrinogen adsorption, platelet adhesion and thrombosis. Conclusion    Compared to the bioprosthetic heart valve materials with glutaraldehyde-based treatment, the materials with non-glutaraldehyde-based treatment show better hemocompatibility.

2.
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery ; (12): 1653-1659, 2022.
Artigo em Chinês | WPRIM | ID: wpr-953732

RESUMO

@#Objective    To study the biocompatibility of bioprosthetic heart valve material with a non-glutaraldehyde-based treatment, and to provide the safety data for the clinical application. Methods    All the tests were conducted according to GB/T16886 standards. The in vitro cytotoxicity was determined by methyl thiazolyl tetrazolium assay. Fifteen guinea pigs were divided into a test group (n=10) and a control group (n=5) in the skin sensitization test. Three New Zealand white rabbits were used in the intradermal reactivity test. Five sites on both sides of the rabbit back were set as test sites and control sites, respectively. In the acute systemic toxicity test, a total of 20 ICR mice were randomly assigned to 4 groups: a test group (polar medium), a control group (polar medium), a test group (non-polar medium) and a control group (non-polar medium), 5 in each group. Forty SD rats were divided into a test group (n=20) and a control group (n=20) in the subchronic systemic toxicity test. Results    The viability of the 100% extracts of the bioprosthetic heart valve material with a non-glutaraldehyde-based treatment was 75.2%. The rate of positive reaction was 0.0%. The total intradermal reactivity test score was 0. There was no statistical difference in the body weight between the test group and control group in the acute systemic toxicity test. There was no statistical difference in the body weight, organ weight, organ weight/body weight ratio, blood routine test or blood biochemistry between the test group and control group in the subchronic systemic toxicity test. Conclusion    The bioprosthetic heart valve material with a non-glutaraldehyde-based treatment has satisfying biocompatibility, which conforms to relevant national standards. The material might be a promising material for application in valve replacement.

3.
Chongqing Medicine ; (36): 3060-3062, 2017.
Artigo em Chinês | WPRIM | ID: wpr-608819

RESUMO

Objective To investigate the assessment of multi-detector spiral CT on the cardiac function after bioprosthetic valve replacement with mitral valve preservation.Methods Thirty-five patients suitable for undergoing bioprosthetic mitral valve replacement in our hospital from May 2012 to February 2014 were randomly divided into 2 groups:group A(experimental group,intraoperative preservation of mitral valve and subvalvular structure during,n=16) and group B (control group,without intraoperative preservation of subvalvular structure of mitral valve,n=19).MDCT before operation and on postoperative 10 d was performed for evaluating the left ventricular function.Results In the comparison of preoperative MDCT,the end diastolic velocity(EDV),end systolic velocity(ESV),ejection fraction(EF) and stroke volume(SV) had no statistical difference between the group A and B.In MDCT results on postoperative 10 d,EDV,ESV and EF in the group A were 113.42±9.22)mL,(38.63±3.40)mL and (51.63±4.71) %,which in the group B were(113.42 ± 9.22) mL,(38.63 ± 3.40) mL and (51.63 ± 4.71) % respectively,the difference was statistically significant(P<0.05),but SV had no statistical difference between the two groups(P>0.05).Conclusion The bioprosthetic valve replacement with mitral valve preservation is safe and feasible in technology,moreover effectively protects the postoperative left ventricular function.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA