Resultados 1 - 20 de 24
Filtrar
1.
J. oral res. (Impresa) ; 11(5): 1-12, nov. 23, 2022. ilus, tab
Artigo em Inglês | LILACS | ID: biblio-1435341

RESUMO

In Purpose: The fabrication technique can influence the mechanical properties of Cobalt-Chromium (Co-Cr) dental alloys. Hence, the present study aims to determine the corrosion resistance and thermal expansion of alloys manufactured using three contemporary techniques. Material and Methods: A total of nine specimens of Co-Cr alloy were prepared according to ISO 22674 by each one of the three manufacturing processes (three in each process); conventional casting, direct metal laser sintering (DMLS) and milling (MIL). All these specimens were tested for coefficient of thermal expansion and corrosion resistance. The data was tabulated and analyzed statistically. Results: The difference in the thermal expansion of alloys fabricated using three techniques was non-significant at almost all the temperatures from 50 ºC to 950 ºC (p>0.05), except 450 ºC and 600 °C. The polarization resistance of specimens manufactured using the conventional method was more compared to DMLS and MIL at pH 5 (Conventional>MIL>DMLS) (p<0.001). Conclusion: The thermal expansion behavior of alloys manufactured using the three selected techniques were similar, whereas, at acidic pH, the corrosion resistance of conventional and MIL were better than the DMLS.


Antecedentes: La técnica de fabricación puede influir en las propiedades mecánicas de las aleaciones dentales de cobalto-cromo (Co-Cr). Por lo tanto, el presente estudio tiene como objetivo determinar la resistencia a la corrosión y la expansión térmica de aleaciones fabricadas con tres técnicas contemporáneas. Material y Métodos: Se prepararon un total de nueve probetas de aleación de Co-Cr según ISO 22674 por cada uno de los tres procesos de fabricación (tres en cada proceso); fundición convencional, sinterización directa de metal por láser (DMLS) y fresado (MIL). Todos estos especímenes fueron probados para determinar el coeficiente de expansión térmica y la resistencia a la corrosión. Los datos fueron tabulados y analizados estadísticamente. Resultados: La diferencia en la dilatación térmica de las aleaciones fabricadas con las tres técnicas no fue significativa en casi todas las temperaturas desde 50ºC hasta 950ºC (p>0,05), excepto 450ºC y 600ºC. La resistencia a la polarización de las muestras fabricadas con el método convencional fue mayor en comparación con DMLS y MIL a pH 5 (Convencional>MIL>DMLS) (p<0, 0 01). Conclusión: El comportamiento de expansión térmica de las aleaciones fabricadas con las tres técnicas seleccionadas fue similar, mientras que, a pH ácido, la resistencia a la corrosión de la convencional y la MIL fue mejor que la de la DMLS.


Assuntos
Humanos , Temperatura , Ligas de Cromo , Corrosão , Ligas Dentárias , Propriedades de Superfície , Técnicas In Vitro , Cromo/química , Cobalto/química , Lasers
2.
Artigo em Inglês | LILACS, BBO | ID: biblio-1155014

RESUMO

ABSTRACT Objective: To determine the effect of sprue design on the marginal accuracy of the casting. Material and Methods: It was an experimental in-vitro study. There are forty-four crowns of single sprue group with a forty-four double sprue group that was compared in 6 different locations of the margin. The sections were inspected under a microscope at 50X magnification and took a micrograph. The radius from an actual casting edge to a possibly excellent margin was then documented as marginal discrepancy (d), in µm. The marginal discrepancy was documented for each of the six sections per casting. Thus 264 sections were measured for each group. Data were analysed using (ANOVA) for analysis of variance. For bivariate analyses, Chi-square and Student t test were used. The significance level was set at < 0.05. Results: The marginal discrepancy was greater in the single sprue group of cast crown (43.1 ± 4.74 µm) and in double sprue group of cast crown was less (25.7 ± 4.25 µm). This difference is statistically significant (p<0.05). The correlation between single sprue group of casting with a double sprue group of casting by student's t-test where determination height was 95%. Conclusion: Double sprue design produces a higher accurate margin than single sprue design in the nickel-chromium alloy cast crown.


Assuntos
Ligas de Cromo , Coroas , Ligas Dentárias , Revestimento para Fundição Odontológica , Materiais Dentários , Técnicas In Vitro/métodos , Distribuição de Qui-Quadrado , Análise de Variância , Níquel
3.
Rev. estomatol. Hered ; 29(2): 115-127, abr. 2019. ilus, tab
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1058490

RESUMO

Las técnicas de cera perdida colado por centrifugación convencional, son técnicas vigentes para obtener cofias de Cobalto-Cromo (Co-Cr) para coronas metalcerámica. Objetivo: Evaluar in vitro, la adaptación marginal e interna de cofias unitarias de aleación Co-Cr, realizadas sobre dos líneas de terminación: chamfer y bisel, fabricadas con las técnicas de cera perdida colada por centrifugación convencional (CPCC) y por inducción (CPCI). Materiales y métodos: Se evaluó la adaptación marginal e interna de 13 cofias unitarias de aleacion Co-Cr para cada tecnica y línea de terminación, usando la técnica de replica de silicona. Las muestras fueron divididas en sentido vestíbulo-palatino y en sentido mesio-distal, observadas en un estéreomicroscopio a un aumento de 40X y se evaluó la zona cervical, axial y oclusal. Resultados: Los analisis estadisticos incluyeron la prueba t de Student y U Mann-Whitney, previamente se evaluo los supuestos de normalidad con la prueba de Shapiro-Wilk para analizar diferencias estadisticamente significativas entre los grupos (p<0.05). La discrepancia marginal fue menor a 120 µm y la discrepancia interna menor a 350µm para ambas líneas de terminación y técnica de colado. Conclusiones: Los resultados en la adaptación marginal e interna de cofias con líneas de terminación chamfer y bisel fabricadas con las técnicas de cera perdida colada por centrifugación convencional e inducción, los valores descriptivos no fueron concluyentes, ya que en la mayoría de los puntos evaluados no existió diferencia estadísticamente significativa. Además en las dos líneas de terminación chamfer y bisel se encontraron rangos clínicamente aceptables.


The techniques of lost wax cast by conventional centrifugation are current techniques to obtain Cobalt-Chrome (Co-Cr) copings for metalceramic crowns. Objective: Evaluate in vitro, the marginal and internal adaptation in unitary Co-Cr alloy copes, made on two termination lines: chamfer and bevel, manufactured with the techniques of lost wax cast by conventional centrifugation (CPCC) and by induction (CPCI), according to type of cut, area and measurement points. Materials and methods: The marginal and internal adaptation of 13 co-units of Co-Cr alloy for each technique and termination line was evaluated. The silicone replication technique was used. The samples were divided in the vestibulo-palatal direction and in the mesio-distal direction, observed in a stereomicroscope at a 40X magnification and the cervical, axial and occlusal areas were evaluated. Results: Statistical analyzes included the Student’s t-test and U Mann-Whitney, previously the assumptions of normality were evaluated with the Shapiro-Wilk test to analyze statistically significant differences between the groups (p <0.05). The marginal discrepancy was less than 120 µm and the internal discrepancy less than 350µm. Conclusion: The results in the marginal and internal adaptation of copings with chamfer termination lines and bevel fabricated with the techniques of lost wax cast by conventional centrifugation and induction were not conclusive to determine which technique is the best since in most of the points evaluated there was not a statistically significant difference. Also in the two lines of termination cnamfer and bevel, there were found clinical acceptable ranges.

4.
Rev. estomatol. Hered ; 29(1): 39-48, ene.-mar. 2019. ilus, tab
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1014044

RESUMO

Nuevas técnicas nos están permitiendo migrar de la técnica de cera perdida colado por centrifugado convencional (CPCC) a técnicas como la cera perdida colado por inducción (CPCI). Objetivos: Comparar la discrepancia marginal e interna de cofias unitarias de aleación Cobalto-Cromo (Co-Cr) sobre una línea de terminación chamfer, confeccionadas con dos técnicas: CPCC y CPCI, determinando cual técnica tuvo mejor adaptación marginal e interna. Material y Métodos: Se fabricaron13 cofias metálicas unitarias de aleación Co-Cr para cada técnica a evaluar. Se utilizó la réplica de silicona para evaluar las discrepancias marginales e internas, cada muestra fue seccionada en cruz en sentido vestíbulo-palatino y en sentido mesio-distal, luego con un estéreomicroscopio se evaluó la zona cervical, axial y oclusal. Resultados: Se evaluó los supuestos de normalidad con la prueba de Shapiro-Wilk. Los análisis estadísticos fueron la prueba t de Student y U Mann-Whitney. La CPCI obtuvo una menor discrepancia marginal e interna en comparación con la CPC pero no se encontró diferencias estadísticamente significativas (p>0,05) entre ambas técnicas. Conclusiones: Aunque en la mayoría de los puntos de evaluación las cofias realizadas mediante la CPCI presento mejores valores de adaptación marginal e interna en comparación con la CPCC estos resultados sólo son valores descriptivos que no fueron concluyentes, ya que en la mayoría de los puntos evaluados no existió diferencia estadísticamente significativa (p>0,05). Observamos que la mayoría de los valores de ambas técnicas se encuentran dentro del rango clínicamente aceptable.


New techniques are allowing us to migrate from the technique of lost wax cast by conventional centrifugation (CPCC) to techniques such as lost wax cast by induction (CPCI). Objectives: To compare the marginal and internal discrepancy of cobalt-chromium (Co-Cr) alloy unit copes on a chamfer termination line, made with two techniques: CPCC and CPCI, determining which technique had better marginal and internal adaptation. Material and Methods: 13 Co-Cr alloy unit copings were fabricated for each technique to be evaluated. Silicon replication was used to evaluate the marginal and internal discrepancies. Each sample was cross-sectioned in the vestibular-palatine and mesio-distal directions, then the cervical, axial and occlusal zones were evaluated with a stereomicroscope. Results: 13 unitary Co-Cr alloy metal cops were manufactured for each technique to be evaluated. The silicone replica was used to evaluate the marginal and internal discrepancies, each sample was cross-sectioned in the vestibulo-palatal direction and in the mesio-distal sense, then with a stereomicroscope, the cervical, axial and occlusal areas were evaluated. Conclusions: The assumptions of normality were evaluated with the Shapiro-Wilk test. The statistical analyzes were Student s t test and U Mann-Whitney test. The CPCI obtained a lower marginal and internal discrepancy compared to the CPC, but no statistically significant differences were found (p >0.05) between both techniques. Conclusions: Although in most of the evaluation points the copings made by the CPCI presented better values of marginal and internal adaptation compared to the CPCC, these results are only descriptive values that were not conclusive, since in most of the evaluated points there was no statistically significant difference (p >0.05). We observed that most of the values of both techniques are within the clinically acceptable range.

5.
Braz. j. oral sci ; 18: e190285, jan.-dez. 2019. tab
Artigo em Inglês | LILACS, BBO | ID: biblio-1088042

RESUMO

Aim: The aim of this study was to evaluate the effect of heat treatment (tempering) on the sliding mechanics of stainless steel Chrome Nickel (CrNi) orthodontic wires. Methods: A universal testing machine EMIC DL 2000 was used at a speed of 10 mm/minute for reading-out the sliding strength and friction between brackets and wires, by simulating the sliding mechanics in a fixed orthodontic appliance. The results were submitted to ANOVA variance test for statistical analysis at the level of 5% (p<0.05). Results: The results indicated that depending on the type of bracket, wire and type of treatment, the groups without heat treatment showed higher mean static friction values, except for groups with CrNi GAC wire and conventional brackets, which showed no significant difference with and without heat treatment; and the group with self-ligated brackets and CrNi GAC wires that showed the lowest mean static friction values with heat treatment. Conclusion: The heat treatment reduced the static friction values on CrNi Morelli wires for any combination of brackets (conventional and self-ligated types) and commercial brands. For the CrNi GAC wires, there was a reduction in friction values only in the combination with In-Ovation R/GAC self-ligated brackets


Assuntos
Fios Ortodônticos , Ligas de Cromo , Braquetes Ortodônticos
6.
Rev. Assoc. Med. Bras. (1992) ; 64(12): 1085-1090, Dec. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-976810

RESUMO

SUMMARY OBJECTIVE; Compare the outcome of spinal deformity correction between Ti-Ti and CrCo-Ti rods for the treatment of spinal Adolescent Idiopathic Scoliosis (AIS) using rods mentioned with all pedicle screws and translation technique. METHOD; 59 patients operated for spinal deformity (Lenke 1 or 2) AIS. The patients were divided into two groups by random allocation using Ti-Ti rods (n = 29) and CrCo-Ti rods (n = 30) and the alone difference among them in the surgical procedure was rod material (Ti-Ti or CrCo-Ti rods) and finally, radiological outcomes were compared preoperatively, postoperatively and at last follow-up for 12 months. RESULTS; Patients' main curve correction after surgical procedure regardless type of rod was 48.95±11.04 (13-75) degree. Success rate of spinal deformity correction following surgical procedure regardless of type of administered rod was 86.76 ± 11.30 percent (62.5-100%). Mean of deformity correction rate was 91.49±10.67% using CrCo-Ti rods versus 81.86±9.88% using Ti-Ti rods (P-value=0.01). Angle change was 3.29±6.60 for kyphosis angle and 0.59±7.76 for lordosis angle. Rate of main curve correction was not significantly different considering patients' gender (P-value0.657). Main curve correction success rate was in association with patients' age and type of rod (P-value=0.054, r=-1.863 and P-value=0.001, r=8.865 respectively). CONCLUSION; CrCo-Ti rods have the ability to produce higher correction rates in AIS compared to Ti-Ti rod of the same diameter. CrCo-Ti rods provide significant and stable spinal correction, especially in correction of main curve. This rate was associated with patients' age and type of rod administered but not gender.


RESUMO OBJETIVO: Comparar o resultado da correção da deformidade da coluna vertebral com ligas de Ti-Ti e CrCo-Ti para o tratamento da Escoliose Idiopática do Adolescente (EIA) na coluna usando as ligas mencionadas com todos os parafusos pediculares e técnica de tradução. MÉTODO: 59 pacientes operados por EIA com deformidade da coluna vertebral (Lenke 1 ou 2). Os pacientes foram divididos em dois grupos por alocação aleatória usando ligas de Ti-Ti (n = 29) e ligas de CrCo-Ti (n = 30) e a única diferença entre eles no procedimento cirúrgico foi o material da liga (ligas de Ti-Ti ou CrCo-Ti) e, finalmente, resultados radiológicos foram comparados no pré-operatório, pós-operatório e no último retorno por 12 meses. RESULTADOS: A correção da curva principal do paciente após o procedimento cirúrgico, independentemente do tipo de liga, foi de 48,95±11,04 (13-75) graus. A taxa de sucesso da correção da deformidade da coluna vertebral após o procedimento cirúrgico, independentemente do tipo de liga administrada, foi de 86,76 ± 11,30% (62,5-100%). A média da taxa de correção da deformidade foi de 91,49±10,67% usando ligas de CrCo-Ti e 81,86±9,88% usando ligas de Ti-Ti (valor de P = 0,01). A mudança de ângulo foi de 3,29±6,60 para o ângulo de cifose e de 0,59±7,76 para o ângulo de lordose. A taxa de correção da curva principal não foi significativamente diferente considerando o sexo dos pacientes (Valor de P 0,657). A taxa de sucesso da correção da curva principal foi associada à idade do paciente e ao tipo de liga (valor de P=0,054, r=-1,863 e valor de P=0,001, r=8,865, respectivamente). CONCLUSÃO: As ligas de CrCo-Ti têm a capacidade de produzir taxas de correção mais altas em EIA em comparação com a liga de Ti-Ti do mesmo diâmetro. As ligas de CrCo-Ti fornecem uma correção espinhal significativa e estável, especialmente na correção da curva principal. Essa taxa foi associada à idade e ao tipo de liga administrada, mas não ao sexo.


Assuntos
Humanos , Masculino , Feminino , Criança , Adolescente , Desenho de Prótese , Escoliose/cirurgia , Fusão Vertebral/instrumentação , Fixadores Internos , Irã (Geográfico) , Cifose/cirurgia , Escoliose/diagnóstico por imagem , Titânio , Pinos Ortopédicos , Radiografia , Ligas de Cromo , Resultado do Tratamento , Cobalto , Cifose/diagnóstico por imagem
7.
Chinese Journal of Stomatology ; (12): 141-144, 2018.
Artigo em Chinês | WPRIM | ID: wpr-806029

RESUMO

Cobalt-chromium alloys have been applied to dental porcelain fused to metal (PFM) restorations over the past decades owing to their excellent corrosion resistance, good biocompatibility and low price. The production of CoCr metal-ceramic restorations has always been based on traditional lost-wax casting techniques. However, in recent years, selective laser melting (SLM) is becoming more and more highly valued by dental laboratories and dental practitioners due to its individuation, precision and efficiency. This paper mainly reviews the recent researches on the production process of copings, microstructure, mechanical property, metal-ceramic bond strength, fit of copings, corrosion resistance and biocompatibility of SLM CoCr metal-ceramic alloy.

8.
Rev. estomatol. Hered ; 27(3): 163-175, jul.-set. 2017. ilus, tab
Artigo em Espanhol | LILACS | ID: biblio-991185

RESUMO

Las nuevas tecnologías digitalizadas han permitido mejorar la adaptación marginal e interna de una restauración, permitiendo migrar de la técnica de cera pérdida colada por centrifugación (CPC) a la fabricación aditiva y sustractiva por CAD/CAM como el sistema de fresado de bloque blando (SMB). Objetivos: Comparar las discrepancias marginal e interna de cofias unitarias de aleación Co-Cr sobre una línea de terminación chamfer, confeccionadas con dos técnicas: CPC y SMB, determinando cual técnica tuvo mejor adaptación marginal e interna. Material y Métodos: Se fabricaron 13 cofias metálicas unitarias de aleación Co-Cr para cada técnica a evaluar. Se utilizó la réplica de silicona para evaluar las discrepancias marginales e internas, cada muestra fue seccionada en cruz en sentido vestíbulo-palatino y en sentido mesio-distal, luego con un estéreomicroscopio se evaluó la zona cervical, axial y oclusal. Resultados: Se evaluó los supuestos de normalidad con la prueba de Shapiro-Wilk. Los análisis estadísticos fueron la prueba t de Student y U Mann-Whitney. La SMB obtuvo una menor discrepancia marginal en sentido vestíbulo-palatino en comparación con la CPC encontrándose diferencia estadísticamente significativas (p<0,05), pero en sentido mesio-distal numéricamente el SMB obtuvo una menor discrepancia marginal pero no hubo diferencia estadísticamente significativa (p<0,05). La menor discrepancia interna fue para CPC en la zona axial tanto en sentido vestíbulo-palatino y mesio-distal con diferencia estadísticamente significativa (p<0,05) pero en la zona oclusal tanto en sentido vestíbulo-palatino y mesio-distal presentaron menor discrepancia interna la SMB con diferencia estadísticamente significativa (p<0,05). Conclusiones: Las cofias que presentaron una mejor adaptación marginal fueron las que se confeccionaron mediante la SMB. Las que presentaron mejor adaptación interna en la zona axial fueron las cofias realizadas mediante la CPC y en la zona oclusal presentaron mejor adaptación interna la SMB.


The new digitized technologies have allowed to improve the marginal and internal adaptation of a restoration, allowing to migrate from the technique of wax loss by centrifugation (CPC) to the additive and subtractive manufacture by CAD / CAM system soft milling block (SMB). Objective: To compare the marginal and internal discrepancies of Co-Cr alloy copings units on a chamfer termination line made with two techniques: CPC y SMB, determining which technique had better marginal and internal adaptation. Material and Methods: 13 Co-Cr alloy unit copings were fabricated for each technique to be evaluated. Silicon replication was used to evaluate the marginal and internal discrepancies. Each sample was cross-sectioned in the vestibular-palatine and mesio-distal directions, then the cervical, axial and occlusal zones were evaluated with a stereomicroscope. Results: The normality assumptions were evaluated with the Shapiro-Wilk test. Statistical analyzes were Student's t test and U Mann-Whitney test. The SMB had a smaller marginal discrepancy in the vestibular-palatine sense compared to CPC, with a statistically significant difference (p <0.05), but in the mesio-distal sense the SMB had a smaller marginal discrepancy but no statistically significant difference (p <0.05). The lowest internal discrepancy was for CPC in the axial zone, both in the vestibular-palatine and mesio-distal directions, with a statistically significant difference (p <0.05), but in the occlusal area both in the vestibular-palatine and mesio-distal directions, The SMB with a statistically significant difference (p <0.05). Conclusions: The copings that presented a better marginal adaptation were those that were made by the SMB. The ones that presented better internal adaptation in the axial zone were the cofias realized by the CPC and in the occlusal zone the SMB presented better internal adaptation.

9.
Braz. j. oral sci ; 15(3)July-Sept. 2016. ilus
Artigo em Inglês | LILACS, BBO | ID: biblio-875039

RESUMO

Choosing the right chemical cleanser for removable partial dentures is a challenge, because they present an acrylic and a metallic portion, which should be cleaned and not damaged. Aim: The aim of this study was to assess surface changes of cobalt chromium alloys immersed in diferente cleaners solutions: 0.05% sodium hypochlorite, 4.2% acetic acid, 0.05% sodium salicylate, sodium perborate (Corega Tabs®) and 0.2% peracetic acid. Material and Methods: One hundred and twenty circular specimens (10 mm in diameter) of two commercial available Co-Cr alloys were tested: GM 800 ® (Dentaurum) and Co-Cr® (DeguDent). The samples were randomly divided into tem experimental groups (n=10), according to the trend mark of alloy and cleaners solutions in which they were immersed, and two control groups, in which the samples of the two alloys were immersed in distilled water. Evaluations were performed through roughness measurement (rugosimeter Surftest 211, Mitutoyo), visual evaluation with stereomicroscope (Stereo Discovery 20, Carl Zeiss) and scanning electron microscope surface (JSM, 6360 SEM, JEOL), at experimental times T0 ­ before immersions, T1 - after one immersion, and T2 - after 90 immersions. Intergroup comparison for the effect of immersion in the different cleanser agents was evaluated through ANOVA/Tukey tests (p≤0.05). The effect of the time in the immersion of each alloy was evaluated by t-pared test (p≤0.05). The two alloys were compared using the t-Student test. Results: The analysis of roughness and microscopy showed that surface changes were significantly greater in groups submitted to 0.05% sodium hypochlorite after 90 immersions (T2). When comparing the two alloys, a similar behavior of roughness was observed for the cleaning agents. However, alloy GM 800® showed significant statistical difference for roughness variations in experimental times (Δ1 and Δ2), when immersed in sodium 0.05% hypochlorite. The number of exposures of the alloys to the cleaning agents showed a negative influence when using sodium hypochlorite solution. Conclusions: It is possible to conclude that 0.05% sodium hypochlorite has caused the greatest apparent damage to alloy surface. (AU)


Assuntos
Ligas de Cromo , Ligas Dentárias , Higienizadores de Dentadura , Hipoclorito de Sódio , Prótese Parcial Removível
10.
The Journal of Advanced Prosthodontics ; : 1-8, 2016.
Artigo em Inglês | WPRIM | ID: wpr-211473

RESUMO

PURPOSE: The purpose of this study was to evaluate the efficacy of two different metal conditioners for non-precious metal alloys for the bonding of porcelain to a cobalt-chromium (Co-Cr) alloy. MATERIALS AND METHODS: Disk-shaped specimens (2.5x10.0 mm) were cast with Co-Cr alloy and used as adherend materials. The bonding surfaces were polished with a 600-grid silicon carbide paper and airborne-particle abraded using 110 microm alumina particles. Bonding specimens were fabricated by applying and firing either of the metal conditioners on the airborne-particle abraded surface, followed by firing porcelain into 5 mm in diameter and 3 mm in height. Specimens without metal conditioner were also fabricated. Shear bond strength for each group (n=8) were measured and compared (alpha=.05). Sectional view of bonding interface was observed by SEM. EDS analysis was performed to determine the chemical elements of metal conditioners and to determine the failure modes after shear test. RESULTS: There were significant differences among three groups, and two metal conditioner-applied groups showed significantly higher values compared to the non-metal conditioner group. The SEM observation of the sectional view at bonding interface revealed loose contact at porcelain-alloy surface for non-metal conditioner group, however, close contact at both alloy-metal conditioner and metal conditioner-porcelain interfaces for both metal conditioner-applied groups. All the specimens showed mixed failures. EDS analysis showed that one metal conditioner was Si-based material, and another was Ti-based material. Si-based metal conditioner showed higher bond strengths compared to the Ti-based metal conditioner, but exhibited more porous failure surface failure. CONCLUSION: Based on the results of this study, it can be stated that the application of metal conditioner is recommended for the bonding of porcelain to cobalt-chromium alloys.


Assuntos
Ligas , Óxido de Alumínio , Ligas de Cromo , Porcelana Dentária , Incêndios , Resistência ao Cisalhamento , Silício
11.
Chinese Journal of Orthopaedics ; (12): 385-391, 2016.
Artigo em Chinês | WPRIM | ID: wpr-491124

RESUMO

Objective To evaluate mid?term clinical outcomes associated with total hip arthroplasty using metal?on?met?al prosthesis with large diameter femoral head. Methods From March 2007 to December 2009, 153 patients (177 hips) with ad?vanced hip diseases undergoing large diameter femoral head metal?on?metal total hip arthroplasty in our hospital were retrospec?tively analyzed in this study. Clinical physical examination and radiographic examination were used to evaluate hip function and the incidence of complications (implant loosening and inflammatory pseudotumor);ICP?MS method was used to determine serum cobalt ion and chromium ion levels and compare with normal values;revision was set as the prosthesis endpoint to evaluate the five year survival rate of implant. Results A total of 145 patients (169 hips) were followed up for average 72.4 months (67-80 months), the follow?up rate was 94.8% (145/153). For the involved patients, 85 were male (104 hips), 60 were female (65 hips);age 20-78 years old, average 49.3±12.6 years old. All patients received ASRTM?XL large femoral head metal?on?metal to?tal hip arthroplasty operation. At the end of follow?up, the average Harris hip score improved from 44.2±12.6 points preopera?tively to 91.5±5.7 points. A total of 8 patients received revision, 3 for acetabular implant spinout?out and 5 for hip inflammato?ry pseudotumor. The prosthetic survival rate 5 years after operation was 95.3% (161/169) for revision. Serum cobalt (2.89 μg/L) and chromium (3.31 μg/L) ion levels were significantly increased compared with normal value (<0.5 μg/L). Conclusion For the fixation and friction interface disadvantages, acetabular implant spinout?out and inflammatory pseudotumor might occur for patient receiving large femoral head metal?on?metal THA. The mid?term prosthetic survival rate was also low, with metal ion levels increased significantly. For primary THA, large femoral head metal?on?metal prosthesis cannot be the first choice.

12.
The Journal of Korean Academy of Prosthodontics ; : 66-73, 2015.
Artigo em Coreano | WPRIM | ID: wpr-171199

RESUMO

Alveolar bone loss and deformation can be a risk factor in removable prosthetic restoration treatment for partially or fully edentulous patients. The use of implants to solve this problem could improve the support, retention and stability of removable restoration. Attachments used in implant overdenture are versatile. The attachment should be selected according to the patients' conditions. Milled bar has been chosen when readymade bar could not be used because of the narrow distance between implants or firm stability and support of supra-structure were needed. Milled bar design is able to provide cross arch stabilization and comfortability to patients. However, it needs skilled laboratory procedures. Recently, the fabrication of milled bar has become simple and its suitability has been improved through the development of CAD/CAM system. In a 67-year-old female Alzheimer's disease patient with 8 implant fixtures on the fully edentulous site of mandible, implant overdenture with using milled bar and magnet attachment was planned. As rapid treatment was required, CAD/CAM system was used to make a simple laboratory procedure instead of a traditional fabrication process. With this system, implant overdenture with milled bar can be fabricated esthetically and functionally.


Assuntos
Idoso , Feminino , Humanos , Perda do Osso Alveolar , Doença de Alzheimer , Ligas de Cromo , Revestimento de Dentadura , Mandíbula , Fatores de Risco
13.
Tianjin Medical Journal ; (12): 526-528, 2015.
Artigo em Chinês | WPRIM | ID: wpr-473441

RESUMO

Objective To investigate the cytocompatibility of the liching liquids of Co-Cr alloy and Ti alloy on human gingival fibroblasts (HGF). Methods The HGF were treated in vitro with leaching liquids of Co-Cr alloy and Ti alloy, respectively. The DMEM cell medium containing 10% fetal bovine serum was served as a negative control. The viability of HGF treated by two dental alloys were evaluated by means of MTT, and the contents of intracellular reduced glutathione (rGSH) were assayed by kits. The tumor necrosis factor-α(TNF-α) contents were determined in the culture supernatant by ELISA in two groups. The effects of these alloys on the expression of caspase-3 were examined by real time-PCR method. Results Compared with the control group, HGF treated with Co-Cr alloy leaching liquids showed a lower viability ( P <0.05), while Ti alloy leaching liquid promoted the proliferation of HGF. In Co-Cr alloy group, the rGSH content was significantly decreased (P<0.05), while TNF-α content was significantly increased (P<0.05) compared with control group. There were no significant differences in rGSH and TNF-α contents between the Ti alloy group and control group (P>0.05). The expression of caspase-3 was significantly higher in Co-Cr alloy group than that of control group (P<0.05), while there was no significant difference in the expression of caspase-3 between Ti alloy group and control group. Conclusion Results suggest that Co-Cr alloy possesses cytotoxicity, while there is better cell compatibility for Ti alloy.

14.
Dental press j. orthod. (Impr.) ; 17(6): 24e1-24e7, Nov.-Dec. 2012. ilus, graf, tab
Artigo em Inglês | LILACS | ID: lil-669389

RESUMO

OBJECTIVE: This in vitro study verified the resistance to corrosion of metallic brackets, evaluating the superficial aspects in scanning electron microscopy (SEM) and the residual components. METHODS: The sample consisted of 17 sets of brackets of four different metallic alloys: Titanium, Cobalt-Chromium, Stainless steel with low nickel concentration and with titanium nitride coating (NiTi). Twelve sets were submitted to corrosion by immersion in 50 ml of artificial saliva (pH 6.5) and four in saliva (pH 6.5) containing fluoride (2 g/l), all at a temperature of 37 ºC and analyzed after 7, 9 and 11 weeks. One was kept as control set. The analysis consisted in qualitative evaluation of the corrosion by the images obtained on the SEM, in semi-quantitative evaluation of chemical composition of the surface residue by SEM-EDS and the amount of ions released in saliva on evaluation of atomic absorption spectrophotometry. RESULTS: The results showed that the pure titanium brackets and the ones with low nickel concentration were superior regarding resistance to corrosion. The cobalt-chromium alloy showed the greatest corrosion. In the presence of fluoride, it was observed greater variation in all alloys, especially in the ones of NiTi coated steel and the ones of cobalt-chromium. CONCLUSION: Although observed corrosion on the SEM, the spectrophotometry showed low ions release in the artificial saliva, however, the presence of fluoride negatively affected the corrosion resistance.


OBJETIVO: este estudo in vitro verificou a resistência à corrosão de braquetes metálicos, avaliando-se os aspectos superficiais em microscopia eletrônica de varredura (MEV) e os componentes residuais formados. MÉTODOS: a amostra consistiu de 17 conjuntos de braquetes de quatro diferentes ligas metálicas: titânio, cobalto-cromo, aço inoxidável com baixa concentração de níquel e com cobertura de nitreto de titânio (TiN). Doze conjuntos foram submetidos à corrosão por imersão em 50ml de saliva artificial (pH 6,5) e 4 em saliva (pH 6,5) contendo flúor (2g/l), todos sob temperatura de 37ºC, e analisados após 7, 9 e 11 semanas. Uma montagem foi mantida como controle. As análises consistiram na avaliação qualitativa da corrosão por meio das imagens obtidas no MEV, na avaliação semiquantitativa da composição química dos resíduos superficiais por meio de MEV-EDS e da quantidade de íons liberados nas salivas na avaliação da espectrofotometria de absorção atômica. RESULTADOS: os resultados demonstraram que os braquetes com liga de titânio puro e os de aço com baixa concentração de níquel foram superiores em relação à resistência à corrosão. A liga de cobalto-cromo foi a que apresentou maior corrosão. Na presença do flúor, observaram-se maiores alterações em todas as ligas, com destaque para as de aço cobertos com TiN e as de cobalto-cromo. CONCLUSÃO: apesar de se observar a corrosão no MEV, a espectrofotometria mostrou baixo desprendimento de íons nas salivas artificiais, porém a presença do flúor interferiu negativamente na resistência à corrosão.

15.
Braz. dent. j ; 23(4): 387-393, 2012. tab
Artigo em Inglês | LILACS | ID: lil-658015

RESUMO

Chemical disinfectants are usually associated with mechanical methods to remove stains and reduce biofilm formation. This study evaluated the effect of disinfectants on release of metal ions and surface roughness of commercially pure titanium, metal alloys, and heat-polymerized acrylic resin, simulating 180 immersion trials. Disk-shaped specimens were fabricated with commercially pure titanium (Tritan), nickel-chromium-molybdenum-titanium (Vi-Star), nickel-chromium (Fit Cast-SB Plus), and nickel-chromium-beryllium (Fit Cast-V) alloys. Each cast disk was invested in the flasks, incorporating the metal disk to the heat-polymerized acrylic resin. The specimens (n=5) were immersed in these solutions: sodium hypochlorite 0.05%, Periogard, Cepacol, Corega Tabs, Medical Interporous, and Polident. Deionized water was used as a control. The quantitative analysis of metal ion release was performed using inductively coupled plasma mass spectrometry (ELAN DRC II). A surface analyzer (Surftest SJ-201P) was used to measure the surface roughness (µm). Data were recorded before and after the immersions and evaluated by two-way ANOVA and Tukey's test (α=0.05). The nickel release proved most significant with the Vi-Star and Fit Cast-V alloys after immersion in Medical Interporous. There was a significant difference in surface roughness of the resin (p=0.011) after immersion. Cepacol caused significantly higher resin roughness. The immersion products had no influence on metal roughness (p=0.388). It could be concluded that the tested alloys can be considered safe for removable denture fabrication, but disinfectant solutions as Cepacol and Medical Interporous tablet for daily denture immersion should be used with caution because it caused greater resin surface roughness and greater ion release, respectively.


Desinfetantes químicos são normalmente associados a métodos mecânicos para remover manchas e reduzir a formação do biofilme. Este estudo avaliou o efeito de desinfetantes na liberação de íons metálicos e na rugosidade superficial do titânio comercialmente puro, ligas metálicas e resina acrílica termopolimerizável, simulando 180 ensaios de imersões. Espécimes em formato de discos foram confeccionados com titânio comercialmente puro (Tritan), liga de níquel-cromo-molibdênio-titânio (Vi-Star), liga de níquel-cromo (Fit Cast-SB Plus) e liga de níquel-cromo-berílio (Fit Cast-V). Os espécimes (n=5) foram imersos nestas soluções: hipoclorito de sódio a 0,05%, Periogard, Cepacol, Corega Tabs, Medical Interporous e Polident. Como controle, foi utilizada a água deionizada. A análise quantitativa de liberação de íons metálicos foi realizada por meio de espectrometria de massa com plasma indutivamente acoplado (ELAN DRC II). O rugosímetro (Surftest SJ-201P) foi utilizado para medir a rugosidade superficial (µm). Os dados foram registrados antes e depois das imersões e avaliados por ANOVA com dois fatores e teste de Tukey (α=0,05). A liberação de níquel provou ser mais expressiva nas ligas Vi-Star e Fit Cast-V após a imersão em Medical Interporous. Houve diferença significante na rugosidade superficial da resina (p=0,011) após a imersão. O Cepacol causou maior rugosidade superficial de forma significativa. Os produtos de imersão não influenciaram nos resultados da rugosidade do metal (p=0,388). Pode-se concluir que as ligas metálicas testadas podem ser consideradas seguras para a fabricação de próteses removíveis, mas as soluções desinfetantes como o Cepacol e a pastilha Medical Interporous para a imersão diária da prótese devem ser utilizados com cautela, pois causaram maior rugosidade superficial da resina e maior liberação de íons, respectivamente.


Assuntos
Humanos , Bases de Dentadura , Ligas Dentárias/química , Higienizadores de Dentadura/química , Resinas Acrílicas/química , Ligas/química , Alumínio/análise , Berílio/análise , Boratos/química , Cetilpiridínio/química , Clorexidina/análogos & derivados , Clorexidina/química , Ligas de Cromo/química , Cromo/análise , Ácido Cítrico/química , Desinfetantes de Equipamento Odontológico/química , Materiais Dentários/química , Teste de Materiais , Metais/análise , Metais/química , Molibdênio/análise , Níquel/análise , Espectrofotometria Atômica , Propriedades de Superfície , Hipoclorito de Sódio/química , Sulfatos/química , Titânio/análise , Titânio/química
16.
J. appl. oral sci ; 19(5): 483-487, Sept.-Oct. 2011. ilus, tab
Artigo em Inglês | LILACS | ID: lil-600849

RESUMO

OBJECTIVE: Removable partial dentures (RPD) require different hygiene care, and association of brushing and chemical cleansing is the most recommended to control biofilm formation. However, the effect of cleansers has not been evaluated in RPD metallic components. The aim of this study was to evaluate in vitro the effect of different denture cleansers on the weight and ion release of RPD. MATERIAL AND METHODS: Five specimens (12x3 mm metallic disc positioned in a 38x18x4 mm mould filled with resin), 7 cleanser agents [Periogard (PE), Cepacol (CE), Corega Tabs (CT), Medical Interporous (MI), Polident (PO), 0.05 percent sodium hypochlorite (NaOCl), and distilled water (DW) (control)] and 2 cobalt-chromium alloys [DeguDent (DD), and VeraPDI (VPDI)] were used for each experimental situation. One hundred and eighty immersions were performed and the weight was analyzed with a high precision analytic balance. Data were recorded before and after the immersions. The ion release was analyzed using mass spectrometry with inductively coupled plasma. Data were analyzed by two-way ANOVA and Tukey HSD post hoc test at 5 percent significance level. RESULTS: Statistical analysis showed that CT and MI had higher values of weight loss with higher change in VPDI alloy compared to DD. The solutions that caused more ion release were NaOCl and MI. CONCLUSIONS: It may be concluded that 0.05 percent NaOCl and Medical Interporous tablets are not suitable as auxiliary chemical solutions for RPD care.


Assuntos
Ligas de Cromo/farmacocinética , Prótese Parcial Removível , Higienizadores de Dentadura/farmacologia , Análise de Variância , Biofilmes/efeitos dos fármacos , Imersão , Íons/farmacocinética , Espectrometria de Massas , Teste de Materiais , Propriedades de Superfície , Fatores de Tempo
17.
J. appl. oral sci ; 18(5): 487-492, Sept.-Oct. 2010. graf
Artigo em Inglês | LILACS | ID: lil-564183

RESUMO

The interest in using titanium to fabricate removable partial denture (RPD) frameworks has increased, but there are few studies evaluating the effects of casting methods on clasp behavior. OBJECTIVE: This study compared the occurrence of porosities and the retentive force of commercially pure titanium (CP Ti) and cobalt-chromium (Co-Cr) removable partial denture circumferential clasps cast by induction/centrifugation and plasma/vacuum-pressure. MATERIAL AND METHODS: 72 frameworks were cast from CP Ti (n=36) and Co-Cr alloy (n=36; control group). For each material, 18 frameworks were casted by electromagnetic induction and injected by centrifugation, whereas the other 18 were casted by plasma and injected by vacuum-pressure. For each casting method, three subgroups (n=6) were formed: 0.25 mm, 0.50 mm, and 0.75 mm undercuts. The specimens were radiographed and subjected to an insertion/removal test simulating 5 years of framework use. Data were analyzed by ANOVA and Tukey's to compare materials and cast methods (α=0.05). RESULTS: Three of 18 specimens of the induction/centrifugation group and 9 of 18 specimens of plasma/vacuum-pressure cast presented porosities, but only 1 and 7 specimens, respectively, were rejected for simulation test. For Co-Cr alloy, no defects were found. Comparing the casting methods, statistically significant differences (p<0.05) were observed only for the Co-Cr alloy with 0.25 mm and 0.50 mm undercuts. Significant differences were found for the 0.25 mm and 0.75 mm undercuts dependent on the material used. For the 0.50 mm undercut, significant differences were found when the materials were induction casted. CONCLUSION: Although both casting methods produced satisfactory CP Ti RPD frameworks, the occurrence of porosities was greater in the plasma/vacuum-pressure than in the induction/centrifugation method, the latter resulting in higher clasp rigidity, generating higher retention force values.


Assuntos
Ligas de Cromo/química , Técnica de Fundição Odontológica , Retenção de Dentadura , Titânio/química , Revestimento para Fundição Odontológica , Grampos Dentários , Prótese Parcial Removível , Teste de Materiais , Porosidade , Pressão , Propriedades de Superfície , Fatores de Tempo , Vácuo
18.
Rio de Janeiro; s.n; 2009. 69 p. ilus, tab, graf.
Tese em Português | LILACS, BBO | ID: lil-533494

RESUMO

O objetivo deste trabalho foi comparar, por meio de teste de microdureza e técnicas de caracterização metalúrgica, que inclui a metalografia, microscopia óptica, microscopia eletrônica de varredura (MEV) e espectroscopia por dispersão de energia (energy dispersive spectroscopy – EDS), propriedades mecânicas e metalúrgicas de juntas soldadas pelos métodos TIG e brasagem em uma liga odontológica à base de Ni-Cr (FIT-CAST SB). As regiões estudadas em cada amostra foram o metal de base (MB), a zona termicamente afetada (ZTA) e a zona de fusão (ZF). Foram confeccionados 40 corpos-de-prova cilíndricos, em forma de bastão, com 2,5mm de diâmetro e 18,0mm de comprimento, obtidos apartir de fundição odontológica por centrifugação (técnica da cera perdida). Foram separados vinte cilindros para cada técnica, que após a soldagem formaram grupos de dez amostras para cada procedimento. A microestrutura do MB apresentou-se como uma matriz de uma solução sólida à base de Ni-Cr contendo um típico arranjo dendrítico de estrutura eutética. A liga apresentou precipitados metálicos na região interdendrítica da estrutura eutética. A análise química semi-quantitativa obtida através da técnica de EDS apresentou resultados compatíveis com a composição química quantitativa fornecida pelo fabricante da liga. Na brasagem, o MB e a ZF apresentaram microestruturas distintas. A ZF apresentou uma morfologia dendrítica grosseira com a presença de precipitados e porosidades. A análise química semi quantitativa por EDS da ZF mostrou-se bastante semelhante aos resultados obtidos para o MB...


The purpose of this study was to compare, by means of microhardness testing and metallurgical characterization techniques as metallography, optical microscopy, scanning electron microscopy (SEM) and energy dispersion spectroscopy (EDS), mechanical and metallurgical properties of welded joints by TIG and brazing methods in a dental alloy based on Ni-Cr (FIT-CAST SB). The studied regions in each sample were the base metal (MB), the heat affected zone (ZTA) and the fusion zone (ZF). Forty cylindrical bodies-of-proof, stick-shaped, with 2.5mm diameter and 18.0mm in length were made from dental casting by centrifugation (lost wax technique). Twenty cylinders were used for each technique, which formed, after the welding, groups of ten samples for each procedure. The microstructure of the MB is presented as a matrix of a solid solution based on Ni-Cr with a typical dendritic arrangement of eutectic structure. The alloy presented metallic precipitates in the interdendritic region of the eutectic structure. The semiquantitative chemical analysis obtained by EDS technique showed results consistent with the quantitative chemical composition provided by the alloy manufacturer. In the brazing method, the MB and ZF showed different microstructures. The ZF showed a rough dendritic morphology with the presence of precipitates and porosities. The semiquantitative chemical analysis by EDS of the ZF had very similar results to those obtained for the MB...


Assuntos
Ligas de Cromo , Níquel , Soldagem em Odontologia/instrumentação , Soldagem em Odontologia/métodos , Tungstênio , Testes de Dureza , Microscopia , Microscopia Eletrônica de Varredura
19.
Braz. dent. j ; 19(3): 209-213, 2008. ilus, graf
Artigo em Inglês | LILACS | ID: lil-495974

RESUMO

The objective of this study was to evaluate the retention force of T-bar clasps made from commercially pure titanium (CP Ti) and cobalt-chromium (Co-Cr) alloy by the insertion/removal test simulating 5 years use. Thirty-six frameworks were cast from CP Ti (n=18) and Co-Cr alloy (n=18) with identical prefabricated patterns on refractory casts from a distal extension mandibular hemi-arch segment. The castings were made on a vacuum-pressure machine, under vacuum and argon atmosphere. Each group was subdivided in three, corresponding to 0.25 mm, 0.50 mm and 0.75 mm undercuts, respectively. No polishing procedures were performed to ensure uniformity. The specimens were subjected to an insertion/removal test and data was analyzed statistically to compare CP Ti and Co-Cr alloy in the same undercut (Student's t-test for independent samples) and each material in different undercuts (one-way ANOVA) (p=0.05). Comparisons between materials revealed significant differences (p=0.017) only for the 0.50-mm undercut. No significant differences (p>0.05) were found when comparing the same material for the undercuts. It may be concluded that for different undercuts, both Co-Cr alloy and CP Ti had no significant differences for T-bar clasps; CP Ti showed the lowest retention force values when compared to Co-Cr alloy in each undercut, but with significant difference only for the 0.50-mm undercut; and both materials maintained the retentive capacity during the simulation test.


O objetivo deste estudo foi avaliar a força de retenção de grampos tipo barra T confeccionados em titânio cp e liga de Co-Cr, através do ensaio de simulação de uso de estruturas metálicas por um período de 5 anos. Sobre modelos de revestimento que simulavam uma extremidade livre unilateral, foram fundidas 36 estruturas em titânio cp (n=18) e em Co-Cr (n=18) utilizando padrões pré-fabricados. As fundições foram feitas em máquina de vácuo-pressão sob vácuo e atmosfera inerte de argônio. Cada grupo foi subdividido em três correspondendo às retenções de 0,25 mm, 0,50 mm e 0,75 mm, respectivamente. Para manter a uniformidade dos grampos, não foram realizados procedimentos de polimento. Os corpos-de-prova foram submetidos ao teste de inserção e remoção e os dados foram analisados estatisticamente (p=0,05) para comparar Ti cp e Co-Cr na mesma retenção (teste T de Student para amostras independentes) e cada material nas diferentes retenções (análise de variância a um fator). A comparação entre os materiais revelou diferença significativa apenas para retenção de 0,50 (p=0,017). Não foram encontradas diferenças quando se comparou o mesmo material nas diferentes retenções (p>0,05). Pode-se concluir que para as diferentes retenções, grampos barra T confeccionados em liga de Co-Cr e titânio não apresentaram diferença estatisticamente significante; o titânio apresentou menores valores de retenção quando comparado à liga de Co-Cr em cada uma das retenções, mas diferença estatisticamente significante só foi encontrada para a retenção 0,50-mm; e ambos materiais mantiveram a capacidade retentiva durante o teste de simulação de uso.


Assuntos
Humanos , Ligas de Cromo/química , Grampos Dentários , Planejamento de Dentadura , Retenção de Dentadura , Prótese Parcial Removível , Materiais Dentários/química , Titânio/química , Argônio/química , Polimento Dentário , Teste de Materiais , Pressão , Estresse Mecânico , Propriedades de Superfície , Vácuo
20.
Journal of Peking University(Health Sciences) ; (6)2004.
Artigo em Chinês | WPRIM | ID: wpr-563030

RESUMO

Objective: To measure the fracture strength of the posterior galvano-ceramic bridges made by Ni-Cr pontic fired bonding galvano caps with highly temperature-resistant adhesive and to provide re-ference data for clinical application. Methods: A standard low dental cast was achieved with 46 missing. Five posterior galvano-ceramic bridges made by Ni-Cr pontic fired bonding galvano caps, with abutments being 47 and 45 . The low dental cast was fixed on the panel of the universal testing machine, vertical load given on the central of the pontic as the velocity of 2 mm/min. Results: The fracture strength of the posterior galvano-ceramic bridges made by Ni-Cr pontic fired bonding galvano caps was (877.00?126.53) N, the fracture strength of the metal frame was (1 448.94?51.02) N. Conclusion: Posterior galvano-ceramic bridges made by Ni-Cr pontic fired bonding galvano caps could endure the normal human occlusal force.