Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.137
Filtrar
1.
Artigo em Chinês | WPRIM | ID: wpr-1022742

RESUMO

Objective To explore the changes in macular microcirculation status and visual function in patients with normal tension glaucoma(NTG)using the optical coherence tomography angiography(OCTA)and microperimeter MP-3 and analyze the correlation between the two.Methods In this cross-sectional observational study,17 NTG patients(30 eyes)were collected as the NTG group and then divided into mild,moderate and severe NTG subgroups according to the severity of the disease.During the same period,13 healthy subjects(23 eyes)with the same age and gender distribution were selected as the control group.OCTA was used to obtain linear density(LD)and perfusion density(PD)of superficial retinal vessels in the macular area.The microperimeter MP-3 was used to measure retinal sensitivity(RS)within 10° and fixation rate at 2° and 4° of the macular area.The OCTA parameters and microperimeter MP-3 parameters were compared among all groups,and the correlation between OCTA parameters and microperimeter MP-3 parameters in NTG patients was analyzed.Results There were no significant differences in LD and PD between the control group and the mild NTG sub-group in the central and nasal sides of the macula;the LD and PD in the remaining regions and overall average LD and PD showed a gradual downward trend in the control group and the mild,moderate and severe NTG subgroups.Compared with the control group,the RS of the mild NTG subgroup was lower in the inferior and temporal regions of the macular area.The RS of each region and overall average RS in the macular area decreased with the aggravation of the NTG.In the NTG group,LD and PD were significantly positively correlated with RS in each region and overall average RS in the macular area(all P<0.05).In the NTG group,LD and PD were positively correlated with P2 in some regions of the macular area.Con-clusion Compared with the control group,the macular microcirculation status and visual function of NTG patients signif-icantly decreased with the progression of the disease;there is a significant correlation between macular LD and RS in NTG patients.

2.
Artigo em Chinês | WPRIM | ID: wpr-1022760

RESUMO

Objective To investigate the detection rate and grading diagnostic value of ultra-wide field swept-source optical coherence tomography angiography(UWF SS-OCTA)combined with ultra-wide field scanning laser ophthalmoscopy(UWF SLO)in diabetic retinopathy(DR)lesions.Methods In this cross-sectional study,diabetic patients attending the Ophthalmology Department of Sichuan Provincial Peoples Hospital were recruited.All participants underwent UWF SS-OC-TA,UWF SLO and fundus fluorescein angiography to detect DR lesions,including microaneurysms(MA),intraretinal hem-orrhages(IRH),nonperfusion areas(NPAs),intraretinal microvascular abnormalities(IRMAs),venous beading(VB),neovascularization elsewhere(NVE),neovascularization of the optic disc(NVD),and vitreous hemorrhage(VH).The re-sults of the combination of three imaging examinations(triple imaging)were used as the standards,evaluating the detec-tion rate and severity grading consistency in DR lesions of pairwise combinations of different imaging modalities.Results A total of 101 patients(175 eyes)were included.Compared with the triple imaging results,the detection rates of UWF SS-OCTA combined with UWF SLO for MA,IRH,NPAs,IRMAs,NVE,NVD and VH were 91%,83%,77%,69%,27%,10%and 12%,respectively,with Kappa values of 0.812,1.000,1.000,1.000,0.986,0.970 and 1.000.Compared with the triple imaging results,the combination of UWF SS-OCTA and UWF SLO demonstrated excellent consistency in grading the severity of DR(Kappa=0.943).Conclusion UWF SS-OCTA combined with UWF SLO can accurately identify MA,IRH,NPAs,IRMAs,NVE,NVD and VH,demonstrating high accuracy in DR screening and grading diagnosis,making it suitable for large-scale screening and management of DR in clinical practice.

3.
Artigo em Chinês | WPRIM | ID: wpr-1022806

RESUMO

Objective:To measure the retinal structural and functional parameters of adult Macaca fascicularis, and explore the similarity of the retinal structural and functional parameters between non-human primates and normal human retinas.Methods:Six eyes of 3 5-year-old adult Macaca fascicularis were examined by in vivo detection including color fundus photography, retinal optical coherence tomography (OCT) and electroretinogram (ERG) to determine the thickness of the inner/outer retina at the fovea and 1 000/2 000 μm away from the nasal, temporal, superior and inferior regions of the fovea, the thickness of the retinal nerve fiber layer (RNFL), the area of optic disc, the area of optic cup, the area ratio of cup to disc and the biological parameters of flash ERG.Differences in the above parameters between left and right eyes were analyzed.The similarity of parameters between Macaca fascicularis and human was compared with reference to published literature.The use and care of animals complied with the Regulation on the Management of Experimental Animals.The study protocol was approved by the Institutional Animal Care and Use Committee of Hubei Topgene Biotechnology (NO.IACUC-2019-012). Results:The foveal thickness, optic disc area, cup-disc area ratio, and average RNFL thickness in normal adult Macaca fascicularis were (252.31±4.79)μm, (1.89±0.05)mm 2, 0.14±0.01, and (103.53±0.58)μm, respectively.The b-wave amplitude of dark-adapted 0.01 ERG was (66.75±7.29)μV.The a- and b-wave amplitudes of dark-adapted 3.0 ERG response were (57.15±15.01) and (122.10±25.51)μV, respectively.The a- and b-wave amplitudes, the amplitude of oscillation potentials, and the latency of dark-adapted 10.0 ERG response were (72.98±20.14)μV, (131.67±13.78)μV, (49.98±10.08)μV, and (30.02±5.76)ms, respectively.The a- and b-wave amplitudes of light-adapted 3.0 ERG were (9.16±2.75) and (40.43±5.57)μV, respectively.The latency and the amplitude of the light-adapted 30 Hz flicker was (26.61±1.19)ms and (24.72±5.10)μV, respectively.There was no significant difference in the parameters between left and right eyes (all at P>0.05). The retinal thickness in central fovea, mean RNFL thickness, waveform and amplitude of ERG of Macaca fascicularis were similar to normal human. Conclusions:The structure and function of the retina of adult Macaca fascicularis are similar to those of normal humans.As a laboratory animal for preclinical drug research, in vivo studies of Macaca fascicularis can refer to normal human retinal parameters.

4.
Artigo em Chinês | WPRIM | ID: wpr-1022834

RESUMO

Objective:To investigate the diagnostic value of an intelligent assisted grading algorithm for nuclear cataract using anterior segment optical coherence tomography (AS-OCT) images.Methods:A diagnostic test study was conducted.AS-OCT image data were collected from 939 cases of 1 608 eyes of nuclear cataract patients at the Shanghai Tenth People's Hospital of Tongji University from November 2020 to September 2021.The data were obtained from the electronic case system and met the requirements for clinical reading clarity.Among them, there were 398 cases of 664 male eyes and 541 cases of 944 female eyes.The ages of the patients ranged from 18 to 94 years, with a mean age of (65.7±18.6) years.The AS-OCT images were labelled manually from one to six levels according to the Lens Opacities Classification System Ⅲ (LOCS Ⅲ grading system) by three experienced clinicians.This study proposed a global-local cataract grading algorithm based on multi-level ranking, which contains five basic binary classification global local network (GL-Net).Each GL-Net aggregates multi-scale information, including the cataract nucleus region and original image, for nuclear cataract grading.Based on ablation test and model comparison test, the model's performance was evaluated using accuracy, precision, sensitivity, F1 and Kappa, and all results were cross-validated by five-fold.This study adhered to the Declaration of Helsinjki and was approrved by Shanghai Tenth People's Hospital of Tongji University (No.21K216).Results:The model achieved the results with an accuracy of 87.81%, precision of 88.88%, sensitivity of 88.33%, F1 of 88.51%, and Kappa of 85.22% on the cataract dataset.The ablation experiments demonstrated that ResNet18 combining local and global features for multi-level ranking classification improved the accuracy, recall, specificity, F1, and Kappa metrics.Compared with ResNet34, VGG16, Ranking-CNN, MRF-Net models, the performance index of this model were improved.Conclusions:The deep learning-based AS-OCT nuclear cataract image multi-level ranking classification algorithm demonstrates high accuracy in grading cataracts.This algorithm may help ophthalmologists in improving the diagnostic accuracy and efficiency of nuclear cataract.

5.
Artigo em Chinês | WPRIM | ID: wpr-1022850

RESUMO

Objective:To evaluate the consistency of the Chinese three-dimensional anterior visual field analysis system (Scansys), the anterior segment analyzer (Pentacam), the frequency-domain anterior segment optical coherence tomography system (CASIA SS-1000), and a new ultra-high frequency digital ultrasound scanning system (Arcscan Insight100) to measure central vault after implantable collamer lens (ICL) implantation in myopic eyes with crystalline lenses.Methods:A diagnostic test study was conducted.Fifty-six myopic patients (56 eyes) who underwent ICL V4c implantation from June to December 2019 were included.Scansys, Pentacam, CASIA and Arcscan were used to measure the central vault after surgery.The vault measurements were compared.Correlations between the measurements of the four instruments were analyzed using Pearson correlation analysis, and consistency comparisons were analyzed using the Bland-Altman method.This study adhered to the Declaration of Helsinki.The study protocol was approved by the Ethics Committee of Henan Eye Hospital (No.HNEECKY-2021[13]). Written informed consent was obtained from each subject.Results:The central vault measurements by Scansys, Pentacam, CASIA and Arcscan were (481.8±191.6), (476.4±190.6), (619.3±207.5) and (534.0±221.2)μm, respectively, with a statistically significant overall difference ( F=143.301, P<0.001). The vault measurements by Scansys and Pentacam were significantly lower than CASIA and Arcscan, and Arcscan was lower than CASIA, with statistically significant differences (all at P<0.001). There were strong positive correlations in vault measurements between Arcscan and CASIA, Arcscan and Pentacam, Arcscan and Scansys, CASIA and Pentacam, CASIA and Scansys, Pentacam and Scansys ( r=0.982, 0.933, 0.931, 0.942, 0.941, 0.989; all at P<0.001). Intraclass correlation coefficients of vault measurements by Scansys, Pentacam, CASIA and Arcscan were 0.985, 0.975, 0.998, 0.992, respectively.The 95% limits of agreement of vault measurements differences were -170 to 0, 0 to 280, 0 to 280, -110 to 210, -100 to 220 μm, between CASIA and Arcscan, CASIA and Scansys, CASIA and Pentacam, Arcscan and Scansys, Arcscan and Pentacam, respectively, and the maximum absolute value of the difference was beyond the clinically acceptable range, showing poor agreement.The 95% limits of agreement of vault measurement difference was -60 to 50 μm between Scansys and Pentacam, showing a good agreement. Conclusions:The repeatability of the vault after ICL V4c implantation in myopic eyes measured by the four instruments is good.Among them, the vault measurements of Scansys and Pentacam are smaller, showing good consistency, and their results could be substituted for each other.The measurement of CASIA is the largest, followed by Arcscan, which have a large difference from each other, and their results can not be substituted for each other, which should be comprehensively analyzed with the actual situation in clinical work.

6.
Artigo em Chinês | WPRIM | ID: wpr-1029805

RESUMO

Objective:To observe the correlation between retinal capillary density and retinal thickness in the macula and spherical equivalent (SE) in school-age children.Methods:A cross-sectional study. From May to December 2022, 182 school-age children who visited the ophthalmology department of the First Affiliated Hospital of Zhengzhou University were included. There were 95 males and 87 females. The age ranged from 6 to 12 years, and the spherical equivalent (SE) was +0.50 to -6.00 D. They were divided into three groups based on the SE of the right eyes: 54 eyes in emmetropia group (+0.50≤SE<-0.50 D), 71 eyes in low myopia group (-0.50≤SE<-3.00 D), and 57 eyes in moderate myopia group (-3.00≤SE≤-6.00 D). The macular area of 6 mm×6 mm was scanned using swept-source optical coherence tomography angiography and was divided into three concentric rings centered on the fovea, including the macular central fovea (0-1 mm diameter), inner ring (1-3 mm diameter) and outer ring (3-6 mm diameter). The retinal thickness and blood flow density of superficial vascular plexus (SVP) and deep vascular plexus (DVP) in different zones within 6 mm of the macular area were measured. The relationships between SE and SVP, DVP and retinal thickness in each ring region were investigated by univariate and multivariate linear regression analyses, smooth curve fitting, and threshold effects.Results:There were significant differences in the SVP ( F=6.64, 26.06, 22.69) and DVP ( F=7.97, 25.01, 5.09) of macular central fovea, inner ring and outer ring among the emmetropia, low myopia and moderate myopia groups ( P<0.05). Univariate linear regression analysis showed that the SVP ( β=-0.56,-1.17, -0.79) and DVP ( β=-1.03, -0.93, -0.45) of the three regions were positively correlated with SE ( P<0.05). After smooth curve fitting, threshold effect analysis and multivariate linear regression analysis, the SVP and DVP in the macular central fovea were linearly positively correlated with SE ( β=-0.91, -1.40; P<0.05), and SVP and DVP in the inner ring and outer ring showed an inverted U-shaped curve relationship with SE with the inflection (<3.00 D). When the SE was less than <3.00 D, the SVP and DVP in the inner ring and outer ring were positively correlated with SE ( P<0.05). When the SE was higher than -3.00 D, except for the DVP in the inner ring region, the other parameters were negatively correlated with SE ( P<0.05). There were significant differences in retinal thickness of the inner ring and outer ring ( F=5.47, 16.36; P<0.05), and no significant difference in the macular central fovea among the emmetropia, low and moderate myopia groups ( F=2.16, P>0.05). By using univariate and multivariate linear regression analyses, the retinal thickness in the inner ring and outer ring were negatively correlated with SE ( β =1.99, 3.05; P<0.05). However, no correlation was found between retinal thickness and SE in the macular central fovea ( β=-1.65, P>0.05). Conclusions:In school-age children with SE between +0.50 D and -6.00 D, the retinal capillaries density of the macular central fovea gradually increase, and increase first and then decrease in the inner ring and outer ring with increasing SE. The retinal thickness of inner ring and outer ring gradually decrease and not change significantly in the macular central fovea.

7.
Artigo em Chinês | WPRIM | ID: wpr-1029813

RESUMO

Objective:To observe the changes of macular structure and microvessels in eyes with diabetes macular ischemia (DMI).Methods:A retrospective case study. From January 2023 to July 2023, 23 patients of 31 eyes diagnosed with DMI at Tangshan Ophthalmological Hospital were included in this study. Among them, there were 14 males with 23 eyes; Female cases with 8 eyes. Age were (59.5±4.6) years old. According to the DMI grading standard formulated by the research group for early treatment of diabetes retinopathy, the patients were divided into mild DMI group, moderate DMI group, and severe DMI group, with 8, 12, and 11 eyes respectively. The blood flow density (VD), perfusion area (FA), small vessel VD (SVD), inner retinal capillary plexus VD, FA, and outer retinal, choroidal, and ganglion cell complex (GCC) thickness within 1 mm of the macular fovea in retinal superficial vascular plexus (SVP)were measured using a scanning frequency light source optical coherence tomography instrument. The changes in macular structure and microvasculature in the affected eyes of different degrees of DMI groups were compared and observed. Inter group comparisons were conducted using one-way ANOVA or Kruskal Wallis H-test. Spearman correlation analysis was used to analyze the correlation between DMI severity and GCC, outer retina, choroid thickness, VD, FA and SVP VD, SVD and FA in inner retina. Results:The GCC ( F=70.670), outer retinal thickness ( H=12.393), VD ( F=105.506), SVD ( H=25.300), FA ( F=107.655), and VD ( H=24.098) and FA ( H=25.300) of the retinal SVP in the mild, moderate, and severe DMI groups were compared, and the differences were statistically significant ( P<0.05). There was no statistically significant difference in choroidal thickness ( H=2.441, P>0.05). Pairwise comparison between groups: VD, SVD, FA of GCC thickness and SVP, and VD of inner retina were statistically significant between severe DMI group and moderate DMI group, and between moderate DMI group and mild DMI group ( P<0.05). The thickness of outer retina was statistically significant between severe DMI group and moderate DMI group ( P<0.05). Inner retinal FA: there were statistically significant differences between severe DMI group, moderate DMI group and mild DMI group ( P<0.05). The correlation analysis results showed that GCC ( r s=-0.918), outer retinal thickness ( r s=-0.448), and inner retinal VD ( r s=-0.894) and FA ( r s=-0.918), as well as VD ( r s=-0.919), SVD ( r s=-0.924), and FA ( r s=-0.939) of retinal SVP, were all negatively correlated with the degree of DMI ( P<0.05). There was no correlation between choroidal thickness and degree of DMI ( r s=-0.081, P>0.05). Conclusion:The thickness of GCC, outer retina and choroid, the VD, SVD, and FA of the retinal SVP, the VD and FA of inner retina are all reduced in eyes with different degrees of DMI, while all of them are negatively correlated with the degree of DMI, except for choroid thickness.

8.
International Eye Science ; (12): 912-916, 2024.
Artigo em Chinês | WPRIM | ID: wpr-1030819

RESUMO

Retinal vein occlusion(RVO)is the second most common cause of vision loss due to retinal vascular disease. Macular edema(ME)is a common complication of RVO and a major cause of central vision impairment. Optical coherence tomography(OCT)is a high-resolution imaging technique that can provide detailed cross-sectional images of the retina and choroid. OCT biomarkers play an important role in the early and accurate diagnosis of RVO-ME, prediction of disease progression, and assessment of visual prognosis. This article provides an overview of various OCT biomarkers for RVO-ME, including retinal thickness, disorganization of retinal inner layers, hyper-reflectivity of retinal inner layer, the integrity of external limiting membrane and ellipsoid zone, the third highest reflectance band of the fovea, hyperreflective dots, paracentral acute middle maculopathy, prominent middle limiting membrane sign, serous retinal detachment height, macular volume and choroidal thickness. These biomarkers serve as objective indicators for evaluating the severity of RVO-ME, guiding treatment decisions, and predicting visual outcomes.

9.
International Eye Science ; (12): 930-936, 2024.
Artigo em Chinês | WPRIM | ID: wpr-1030823

RESUMO

AIM: To explore retinal microvascular changes in migraine patients using meta-analysis.METHODS: The National Library of Medicine PubMed, Embase, and Cochrane Library were searched to find relevant studies, and the search period was from the creation of database to June 2023. Two investigators independently screened the literatures, extracted data, and evaluated the quality of included studies using the NOS scale. STATA15.0 was used for Meta-analysis and publication bias evaluation, sensitivity analysis was performed for results with large heterogeneity, and the funnel plot and Egger were used to assess the publication bias of the literature.RESULTS:A total of 12 studies, including 217 patients(252 eyes)with migraine with aura(MA), 283 patients(388 eyes)with migraine without aura(MO), and 374 healthy individuals(479 eyes), were included in this Meta-analysis. Several optical coherence tomography angiography(OCTA)indicators, including foveal avascular zone(FAZ)macular or optic disc perfusion density were compared and analyzed. The Meta-analysis results showed that compared with healthy controls, patients with MA had a significant increase in FAZ area and perimeter, a significant decrease in perfusion density of the macular deep capillary plexus(mDCP)except for the fovea, and a significant decrease in perfusion density of the radial peripapillary capillaries(RPC)around the optic disc; the FAZ parameters were significantly increased in MO, while the differences in perfusion density of the macular superficial capillary plexus(mSCP), mDCP and RPC were not statistically significant, except for the perfusion density in the parafovea mDCP.CONCLUSIONS: Both MA and MO patients had an enlarged FAZ area, patients with MA had a significant decrease in mDCP perfusion density, and migraine patients had some degree of retinal ischemia.

10.
International Eye Science ; (12): 937-942, 2024.
Artigo em Chinês | WPRIM | ID: wpr-1030824

RESUMO

AIM: To observe the imaging characteristics of the affected eyes of patients with central serous chorioretinopathy(CSC)of different ages and their asymptomatic fellow eyes.METHODS: Retrospective study. A total of 76 cases(88 eyes)of CSC patients diagnosed in the ophthalmology department of our hospital from April to September, 2023 and 35 cases(35 eyes of asymptomatic fellow eyes of patients with unilateral CSC)were selected for the study. According to age, they were divided into young and middle-aged groups(&#x003C;40 years old), middle-aged groups(40-50 years old)and middle-aged and elderly groups(&#x003E;50 years old). The imaging features of the affected eyes of CSC patients of different ages and their asymptomatic fellow eyes were observed.RESULTS: The subfoveal choroidal thickness(SFCT)of CSC eyes in the young and middle-aged patients(487.30±83.33 μm)was significantly greater than that of the middle-aged group(414.17±96.02 μm, P&#x003C;0.05)and the middle-aged and elderly group(409.4±107.42 μm, P&#x003C;0.05). The incidence of choroidal neovascularization(CNV)in CSC patients of the middle-aged and elderly group was significantly higher than that in the young and middle-aged group(P&#x003C;0.0167). The SFCT of the asymptomatic fellow eye of the unilateral CSC patient in the young and middle-aged group(511.29±40.89 μm)was significantly larger than that of the middle-aged and elderly group(364.76±82.26 μm, P&#x003C;0.05). Among them, the vortex vein anastomosis rate in eyes with CSC is higher than 90%, and vortex vein anastomosis or dilatation is present in all asymptomatic fellow eyes of CSC patients.CONCLUSION: There are differences in the imaging manifestations of CSC-affected eyes and their asymptomatic fellow eyes of different age groups. SFCT is generally thickened and gradually becomes thinner with the growth of age. The incidence of CNV in CSC-affected eyes is the highest in the middle-aged and elderly group. In addition, vortex vein anastomosis and dilatation are common in CSC-affected eyes and asymptomatic fellow eyes.

11.
International Eye Science ; (12): 990-993, 2024.
Artigo em Chinês | WPRIM | ID: wpr-1030834

RESUMO

AIM: To compare the efficacy of different dosing regimens of conbercept in the treatment of pathological myopic choroidal neovascularization(CNV).METHODS: Prospective clinical study. Totally 42 patients(42 eyes)who were diagnosed with pathological myopic CNV in our hospital from January 2019 to January 2022 were selected in the study. According to two different initial dosing regimens, the patients were divided into 1+pro re nata(PRN)group, with 20 patients(20 eyes), and 3+PRN group with 22 patients(22 eyes). The patients in the 1+PRN group were given one intravitreal injection and then given PRN, the patients in the 3+PRN group were given intravitreal injection once a month for 3 mo and then given PRN. Followed-up for 12 mo after initial treatment, the best corrected visual acuity(BCVA), central macular thickness(CMT), CNV area and injection times were compared between the two groups.RESULTS: The BCVA was improved, CMT was decreased, and CNV area was reduced at 1, 3, 6, and 12 mo after the initial treatment(P&#x003C;0.01). However, there was no statistically significant difference in BCVA, CMT and CNV area between two groups(P&#x003E;0.05). The average injection in the 1+PRN group was significantly less than that of the 3+PRN group [2(1, 3)times vs 3(3, 4)times, P&#x003C;0.05], but the average reinjection in the 1+PRN group was more than that of the 3+PRN group [1(0, 2)times vs 0(0, 1)times, P&#x003C;0.05].CONCLUSION: Two regimens were both safe and effective in the treatment of pathological myopic CNV by Conbercept, which can improve BCVA, decrease CMT, and reduce CNV area, with less total times of injection in the 1+PRN regimen, and less times of reinjection in the 3+PRN regimen.

12.
Artigo em Chinês | WPRIM | ID: wpr-1031541

RESUMO

ObjectiveTo assess the repeatability (intra-operator variability) and reproducibility (inter-operator variability) of a new partial coherence interferometry (PCI)-based ocular biometer, Myopia Master, and its agreement with IOL Master 500 for measuring axial length (AL) and corneal curvature (K) in children aged 8-12 years. MethodsThe same operator measured school children with the Myopia Master and the IOL Master 500 in random order to assess agreement. Additionally, some of these children received measurements from another operator using the Myopia Master to assess repeatability and reproducibility. AL, flat keratometry (Kf), steep keratometry (Ks), mean keratometry (Km), J0 and J45 were analyzed. The repeatability and reproducibility were assessed by the within-subject standard deviation (Sw), test-retest repeatability (TRT), coefficient of variation (CoV) and intra-class correlation coefficient (ICC). The agreement between the Myopia Master and the IOL Master 500 was assessed by Bland-Altman plots and 95% limits of agreement (LoA). ResultsBoth repeatability and reproducibility of the Myopia Master were high for AL measurements (Sw=0.02 mm, ICC=0.999; Sw=0.04 mm, ICC=0.998), but moderate for K measurements (Sw range, 0.04 to 0.12 D, ICC range, 0.861 to 0.991; Sw range, 0.06 to 0.20 D, ICC range, 0.835 to 0.992). There were significant mean differences between the Myopia Master and the IOL Master 500 in measurements of AL (-0.01±0.04) mm, Kf (-0.09 ± 0.15) D, Ks (-0.47±0.40) D, and Km (-0.28±0.23) D, J0 (0.18±0.20) D and J45 (-0.01±0.12) D. ConclusionsThe Myopia Master provided high repeatability and reproducibility for AL measurements in schoolchildren with myopia, but the Myopia Master and the IOL Master 500 cannot be used interchangeably in measuring AL and K.

13.
International Eye Science ; (12): 1013-1019, 2024.
Artigo em Chinês | WPRIM | ID: wpr-1032340

RESUMO

AIM: To assess the changes of vessel density in the optic disc and macular of the affected eye and the uninvolved contralateral eye in patients with idiopathic optic neuritis(ON)and to provide clinical guidance for the treatment and follow-up of idiopathic ON.METHODS: A total of 16 patients with first-episode monocular idiopathic ON ≤3 mo diagnosed between December 2019 and December 2021 were included in this cross-sectional study. The eye of patients was divided into 16 eyes in the affected eye group and 16 eyes in the uninvolved contralateral eye group, and 20 healthy age-matched eyes(n=20)served as controls. Optical coherence tomography angiography(OCTA)was performed in all eyes at 4.5 mm×4.5 mm region of the optical disc and 6 mm×6 mm region of the macular, and blood flow indicators were collected and compared. RESULTS: Compared with the control group and the uninvolved contralateral eye group, the density of all vessels and capillary were reduced in the whole area of optic disc, and all subdivisions of the peripapillary region in the ON group(all P&#x003C;0.05). Compared with the uninvolved contralateral eye group, the density of superficial capillary plexus(SCP)was significantly lower in the whole area of macular and perifovea region, and its all subdivisions of the ON eye, as well as in the superior-hemi and superior subdivision of the parafovea region(all P&#x003C;0.05). Compared with the control group, the density of SCP in the inferior-hemi, nasal, and inferior perifovea region was significantly reduced in the ON affected eye group(all P&#x003C;0.05). Compared with the control group, the whole area of macular and its subdivisions in the uninvolved contralateral eye group showed an increase in the density of SCP(P&#x003C;0.05)and an increase in the density of SCP in the parafovea region(P&#x003C;0.05), but no significant change in the inferior-hemi and nasal subdivisions; the increase in the density of SCP in the perifovea region was only significant in the superior-hemi and superior subdivisions(P&#x003C;0.05).CONCLUSION: Patients with ON in the duration of ≤3 mo may showed a decreased vessel density in all peripapillary subdivisions, and a decreased density of SCP in some subdivisions of the perifovea region, accompanied by an increased density of SCP in some subdivisions of the macular region of the contralateral eyes.

14.
International Eye Science ; (12): 1058-1063, 2024.
Artigo em Chinês | WPRIM | ID: wpr-1032347

RESUMO

Advances in imaging technology have revolutionized the field of ophthalmology, changing the understanding, diagnosis, and treatment of ophthalmic diseases. Swept-source optical coherence tomography(SS-OCT)is a non-contact high-resolution imaging technology. It further improves imaging depth and scanning speed, adds new algorithms and features. The application of SS-OCT enables the three-dimensional evaluation of corneal structures, offering curvature and height maps for both the anterior and posterior surfaces of the cornea, as well as precise corneal thickness mapping. These invaluable tools aid ophthalmologists in effectively screening and diagnosing various corneal lesions such as keratoconus, corneal dystrophy, and degeneration. Moreover, the enhanced speed, accuracy, and sensitivity provided by SS-OCT measurements facilitate improved surgical planning and postoperative monitoring for patients undergoing refractive surgery or keratoplasty. This article reviews the development of SS-OCT technology and its potential clinical utility in corneal diseases and surgical application, in order to support more possible future research and clinical treatment.

15.
International Eye Science ; (12): 1106-1113, 2024.
Artigo em Chinês | WPRIM | ID: wpr-1032357

RESUMO

AIM:To systematically evaluate the changes in retinal and choroidal thickness in patients with internal carotid artery stenosis by using optical coherence tomography(OCT)through Meta-analysis.METHODS: Literatures on the measurement of retinal and choroidal structure in patients with internal carotid artery stenosis by using OCT from CNKI, VIP, WF, PubMed, the Cochrane Library, SinoMed, and Embase databases were searched for relevant studies. The retrieval time was from the establishment of the databases to January 2024. In addition, quality of the included literatures was assessed by the Newtle-Ottawa scale(NOS), and RevMan 5.4.1 and Stata 16.0 were used for statistical analysis.RESULTS: A total of 17 articles(including 18 studies)were included, and the Meta-analysis results showed that, patients with internal carotid artery stenosis had significantly thinner peripapillary retinal nerve fiber layer(pRNFL), ganglion cell complex(GCC), center macular thickness(CMT), and subfoveal choroidal thickness(SFCT)than the healthy control group(age matched normal population). The pRNFL and SFCT of the ipsilateral eye in patients with internal carotid artery stenosis become thinner compared with the contralateral eye.CONCLUSION:To a certain extent, the morphological structure of the retina and choroid can be altered by stenosis of the internal carotid artery. OCT can non-invasively detect the microstructural changes of the retina and choroid in patients with internal carotid artery stenosis, and can be used for the evaluation of internal carotid artery stenosis.

16.
International Eye Science ; (12): 1147-1151, 2024.
Artigo em Chinês | WPRIM | ID: wpr-1032364

RESUMO

AIM: To observe the multimodal imaging characteristics of Best vitelliform macular dystrophy(BVMD).METHODS:The clinical data of 30 patients(60 eyes)diagnosed as BVMD at stage Ⅰ to Ⅳ in Nanjing Medical University Affiliated Eye Hospital from June 2016 to October 2022 were collected for a retrospective analysis, and all patients are binocular involved. All patients underwent best corrected visual acuity(BCVA), slit lamp microscopy, indirect ophthalmoscopy, intraocular pressure, fundus photography, spectral-domain optical coherence tomography(SD-OCT), fundus autofluorescence(FAF), fundus fluorescein angiography(FFA), electro-oculogram(EOG)and optical coherence tomography angiography(OCTA).RESULTS: A total of 30 patients(60 eyes)were included, with 8 eyes at stage Ⅰ, 24 eyes at stage Ⅱ, 22 eyes at stage Ⅲ and 6 eyes at stage Ⅵ. The imaging characteristics of fundus photography, FAF, FFA and SD-OCT were basically consistent with previous literature reports. EOG showed Arden ratio &#x003C;1.55. OCTA could detect early lesions, observe the location of vitelliform substance, external segment of photoreceptor, fluid and choroidal neovascularization(CNV).CONCLUSION: Multimodal imaging assisted in diagnosing BVMD, reducing missed diagnosis and misdiagnosis, among which OCTA had significant advantages over other examinations, and fast and non-invasive were its biggest advantages.

17.
International Eye Science ; (12): 1173-1178, 2024.
Artigo em Chinês | WPRIM | ID: wpr-1032370

RESUMO

AIM: To explore the neuro-ophthalmological characteristics of acute macular neuroretinopathy(AMN)after SARS-CoV-2 infection.METHODS: A total of 8 patients(14 eyes), including 6 females and 2 males, who were diagnosed with AMN in the neuro-ophthalmology department of Xi'an No.1 Hospital(The First Affiliated Hospital of Northwest University)from December 27, 2022 to February 1, 2023 were included in the study. All patients had a history of SARS-CoV-2 infection before the disease, and the results of best corrected visual acuity(BCVA), non-contact indirect intraocular pressure measurement, fundus color photography, near infrared(IR), spectral-domain optical coherence tomography(SD-OCT), OCT angiography(OCTA), fundus fluorescein angiography(FFA), indocyanine green angiography(ICGA), visual field, visual evoked potential(VEP), and electroretinogram(ERG)were collected. Furthermore, the neuro-opthalmology characteristics of the included patients were analyzed and summarized.RESULTS: The included 8 patients aged from 20 to 43, with an average age of(30±6.63)years old. The patients had a history of SARS-CoV-2 infection 3 to 11(mean 5±3.51)d before the disease, and 6 out of 8 patients developed visual symptoms within 5 d of infection with SARS-CoV-2, with manifestated with decreased vision or visual scotoma. The visual acuity varied from 0.08 to 1.0, with visual field defect characterized by central, paracentral or peripheral scotoma. VEP showed prolongation latency of P100 or P2, and ERG revealed impaired function of retinal photoreceptor cell. In the early stage of the disease, the size and shape of early visual acuity, visual field, and extraretinal lesions in patients with AMN associated with SARS-CoV-2 infection may not match, and the lower the visual acuity, the later the VEP peaks.CONCLUSION: The neuro-ophthalmic features of SARS-CoV-2 infection-associated AMN require the attention of clinicians. In addition to multi-mode fundus imaging, clinicians should use a variety of methods to comprehensively evaluate visual function and prognosis of patients.

18.
Chinese Journal of Neuromedicine ; (12): 256-262, 2024.
Artigo em Chinês | WPRIM | ID: wpr-1035989

RESUMO

Objective:To investigate the application value of optical coherence tomography (OCT) and intravascular ultrasound (IVUS) in evaluating flow diverter (FD) apposition and endothelialization in aneurysm animal models, and analyze the effect of incomplete stent apposition (ISA) on aneurysm lumen healing and stent endothelialization.Methods:Lateral common carotid artery aneurysm models in swines were established by surgical method and then FD was implanted. Immediately after surgery, OCT and IVUS were used to evaluate the locations and degrees of ISA, and difference between these 2 methods in evaluating FD apposition was compared. DSA was performed at 12 weeks after surgery to evaluate the aneurysm occlusion (Kamran grading) and stent patency. OCT and IVUS were used again to observe the stent endothelial situation; by comparing with histopathologic results, effect of ISA on aneurysm healing and stent endothelialization was analyzed.Results:Lateral common carotid artery aneurysm models in 6 swines were established, and 6 Tubridge FDs were successfully implanted. Compared with IVUS (3 stents, 4 locus), OCT could detect more ISA (6 stents, 14 locus); and the vascular diameter change area (7 locus), aneurysm neck area (4 locus) and the head and tail of FD (3 locus) were the main sites of FD malapposition; average distance between stent wire and vessel wall was (560.14±101.48) μm. At 12 weeks after surgery, DSA showed that 1 patient had a little residual contrast agent at the aneurysm neck (Kamran grading 3), and the remaining 5 had complete aneurysm occlusion (Kamran grading 4). One FD had moderate lumen stenosis, and the other 5 FDs had lumen patency. OCT indicated mostly disappeared acute ISA; ISA proportion decreased to 21.4 % (3/14), including 2 in the aneurysm neck and 1 in the partial stent. Histopathological results showed bare stent woven silk, without obvious endothelial coverage; in one FD with luminal stenosis, intimal hyperplasia was mainly composed of vascular smooth muscle cells.Conclusion:In carotid artery aneurysm model with FD implantation, OCT can detect more ISA than IVUS; most acute ISA have good outcome at 12 th week of follow-up, while severe ISA can cause delayed FD endothelialization and delayed aneurysm occlusion.

19.
Artigo em Chinês | WPRIM | ID: wpr-1036288

RESUMO

@#Vertical root fracture is a type of longitudinal crack originating from the roots of teeth that can occur in vital teeth and teeth after root canal treatment. It is a hard tissue disease of teeth with a complex etiology and poor prognosis. The vertical root fracture that occurs in teeth after pulp treatment is called secondary vertical root fracture (SVRF). A comprehensive judgment should be made based on clinical signs such as pain, swelling, tooth looseness, sinus located near the gum edge, and deep and narrow isolated periodontal pockets, as well as apical films such as periodontal membrane widening, vertical and root bone loss, and “halo” or “J” shaped transmission shadows around the root. For teeth suspected of longitudinal root fractures, three-dimensional imaging such as cone beam computed tomography (CBCT) should be used to assist in the diagnosis. If CBCT shows a defect in the buccal or lingual bone plate, it can increase the possibility of diagnosing SVRF. The setting of CBCT parameters should be optimized by using small field CBCT, enhancing dye-assisted applications, and metal artifact reduction (MAR) tools to reduce the impact of artifacts and improve the accuracy of CBCT diagnosis of SVRF. Magnetic resonance imaging (MRI), digital subtraction radiography (DSR), optical coherence tomography (OCT), and other imaging techniques can detect cracks of different widths, and artificial intelligence (AI) diagnostic technology and predictive models provide further auxiliary means for SVRF diagnosis. SVRF cannot be determined through noninvasive methods, and the final diagnostic method is to detect the presence of SVRF through direct observation within the root canal and during flap surgery.

20.
International Eye Science ; (12): 10-17, 2024.
Artigo em Chinês | WPRIM | ID: wpr-1003498

RESUMO

AIM: To quantify early changes of macular capillary parameters in type 2 diabetic patients using optical coherence tomography angiography(OCTA).METHODS: Retrospective case study. A total of 49 healthy subjects, 52 diabetic patients without retinopathy(noDR)patients, and 43 mild nonproliferative diabetic retinopathy(mNPDR)patients were recruited. Capillary perfusion density, vessel length density(VLD), and average vessel diameter(AVD)were calculated from macular OCTA images(3 mm×3 mm)of the superficial capillary plexus after segmenting large vessels and the deep capillary plexus. Parameters were compared among control subjects, noDR, and mNPDR patients. The area under the receiver operating characteristic curve estimated the abilities of these parameters to detect early changes of retinal microvascular networks.RESULTS: Significant differences were found in the VLD and AVD among the three groups(P&#x0026;#x003C;0.001). Compared with the control group, the noDR group had significantly higher AVD(P&#x0026;#x003C;0.05). VLD of both layers in patients of mNPDR group was significant decreased compared with that of noDR group(all P&#x0026;#x003C;0.01). Deep AVD had a higher area under the curve(AUC)of 0.796 than other parameters to discriminate the noDR group from the healthy group. Deep AVD had the highest AUC of 0.920, followed by that of the deep VLD(AUC=0.899)to discriminate the mNPDR group from the healthy group.CONCLUSIONS: NoDR patients had wider AVD than healthy individuals and longer VLD than mNPDR patients in both layers. When compared with healthy individuals, deep AVD had a stronger ability than other parameters to detect early retinal capillary impairments in noDR patients.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA