Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Adicionar filtros








Intervalo de ano
1.
Rev. bras. ginecol. obstet ; 45(1): 31-37, 2023. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1431617

RESUMO

Abstract Objective To evaluate the expulsion and continuation rates of the copper intrauterine device (IUD) inserted in the immediate postpartum period in a Brazilian public university hospital. Materials and Methods In the present cohort study, we included women who received immediate postpartum IUD at vaginal delivery or cesarean s March 2018 to December 2019. Clinical data and the findings of transvaginal ultrasound (US) scans performed 6-weeks postpartum were collected. The expulsion and continuation rates were assessed 6-months postpartum using data from the electronic medical records or by telephone contact. The primary outcome was the proportion of IUDs expelled at 6 months. For the statistical analysis, we used the Student t-test, the Poisson distribution, and the Chi-squared test. Results There were 3,728 births in the period, and 352 IUD insertions were performed, totaling a rate of 9.4%. At 6 weeks postpartum, the IUD was properly positioned in 65.1% of the cases, in 10.8% there was partial expulsion, and in 8.5% it had been completely expelled. At 6 months postpartum, information was obtained from 234 women, 74.4% of whom used IUD, with an overall expulsion rate of 25.6%. The expulsion rate was higher after vaginal delivery when compared with cesarean section (68.4% versus 31.6% respectively; p = 0.031). There were no differences in terms of age, parity, gestational age, final body mass index, and newborn weight. Conclusion Despite the low insertion rate of copper IUDs in the postpartum period and a higher expulsion rate, the rate of long-term continuation of intrauterine contraception was high, indicating that it is a useful intervention to prevent unwanted pregnancies and to reduce short-interval birth.


Resumo Objetivo Avaliar as taxas de expulsão e continuação do dispositivo intrauterino (DIU) de cobre inserido no pós-parto imediato em um hospital universitário brasileiro. Materiais e Métodos Neste estudo de corte transversal, foram incluídas parturientes submetidas à inserção de DIU de cobre no pós-parto imediato entre março de 2018 e dezembro de 2019. Foram coletados dados clínicos e da ultrassonografia (US) transvaginal realizada após seis semanas. As taxas de expulsão e de continuação foram avaliadas após seis meses por meio de dados do prontuário ou por contato telefônico. O resultado principal foi a proporção de DIUs expelidos em seis meses. Para análise estatística, utilizaram-se o teste t de Student, a distribuição de Poisson, e o teste do Qui quadrado. Resultados Houve 3,728 nascimentos no período, e foram inseridos 352 DIUs, em uma taxa de 9,4%. Com 6 semanas, o DIU estava bem posicionado em 65,1% dos casos, em 10,8%, houve expulsão parcial, e, em 8,5%, fora totalmente expelido. Aos 6 meses de pós-parto, foram obtidas informações de 234 mulheres, 74,4% das quais usavam DIU, com uma taxa de expulsão geral de 25,6%. A taxa de expulsão foi maior após o parto vaginal do que após cesariana (68,4% versus 31,6%, respectivamente; p = 0,031). Não houve diferenças quanto à idade, paridade, idade gestacional, índice de massa corpórea final, e peso do recém-nascido. Conclusão Apesar da baixa taxa de inserção e alta taxa de expulsão, a taxa de continuação em longo prazo da contracepção intrauterina com DIU de cobre foi elevada, o que indica que se trata de intervenção útil para prevenir gestações indesejadas em curto intervalo de tempo.


Assuntos
Humanos , Feminino , Anticoncepção
2.
Rev. bras. ginecol. obstet ; 43(4): 291-296, Apr. 2021. tab
Artigo em Inglês | LILACS | ID: biblio-1280045

RESUMO

Abstract Objective To evaluate whether continuation rates with the 52-mg levonorgestrelreleasing intrauterine system (LNG-IUS) up to 5 years after placement differed between women using the method exclusively for contraception and those using the device for medical reasons alone. Methods A retrospective cohort study was conducted in a family planning clinic with 5,034 LNG-IUS users: 4,287 using the method exclusively for contraception and 747 for medical reasons alone. The continuation rate at 1 to 5 years of use was calculated by life table analysis. Results Initially, the continuation rate was significantly higher in the contraception group: 85.8 versus 83.4 and 77.4 versus 76.0 per 100 women-years in the 1st and 2nd years of use, respectively. There were more discontinuations due to bleeding/spotting in the medical reasons group in the first two years. The discontinuation rate according to reason for use was not significantly different from the third to the fifth year of use. No women discontinued due to amenorrhea in either group. Conclusion The continuation rate was significantly higher in the contraception group in the first two years of use. Amenorrhea was not a reason for discontinuation in either group, suggesting that counselling in this respect was adequate. Nevertheless, counselling could perhaps have been better with regards to the expected long period of bleeding and spotting in the first two years after placement.


Resumo Objetivo Avaliar a taxa de continuação até 5 anos de uso do sistema intrauterino liberador de 52-mg levonorgestrel por dia (SIU LNG) -IUS) é diferente entre mulheres que o usam exclusivamente como anticoncepcional que entre as que usam exclusivamente por razões médicas. Métodos Estudo retrospectivo realizado em uma clínica de Planejamento Familiar 5.034 usuárias de SIU LNG, 4.287 que optaram pelo método apenas como anticoncepcional e 747 que o usavamsomente por razoesmédicas. A taxa de continuação de um até cinco ano foi calculada por meio de análise de tabela de vida Resultados No início a taxa de continuação foi significativamente maior no grupo da anticoncepção: 85,8 versus 83,4 e 77,4 versus 76,0 por 100 anos-mulher no 1° e 2° ano de uso, respectivamente. Houve mais descontinuações por sangrado-manchado no grupo de razões médicas nos dos primeiros anos. A taxa de continuação não foi significativamente diferente desde o terceiro até o quinto ano de uso. Nenhuma mulher de ambos os grupos descontinuou por amenorreia. Conclusão A taxa de continuação foi significativamente maior no grupo de anticoncepção durante os dos primeiros anos de uso. Amenorreia não foi motivo de descontinuação em ambos os grupos, sugerindo que a orientação a esse respeito foi adequada. Entretanto, a orientação referente ao longo período de sangramentos irregulares nos dois primeiros anos após a inserção, precisaria ser melhorado.


Assuntos
Humanos , Feminino , Adulto , Adulto Jovem , Levanogestrel/administração & dosagem , Contraceptivos Hormonais/administração & dosagem , Dispositivos Intrauterinos Medicados/efeitos adversos , Paridade , Brasil , Educação de Pacientes como Assunto , Análise de Regressão , Estudos Retrospectivos , Seguimentos , Levanogestrel/efeitos adversos , Estado Civil , Aconselhamento , Escolaridade , Contraceptivos Hormonais/efeitos adversos , Distúrbios Menstruais
3.
Artigo | IMSEAR | ID: sea-206958

RESUMO

Background: Family planning is important not only for population stabilization, but it has been increasingly recognized as central tool to improve maternal and neonatal health. Aim of current study was to compare interval and post partum intrauterine contraceptive device (IUCD) insertion in terms of effectiveness and safety.Methods: This was a prospective observational cohort study, done in the department of Obstetrics and Gynecology, GMERS Medical College, Sola, Ahmedabad, from August 2015 to April 2017 was taken for evaluation. 80 women in each group who were inserted IUCD after delivery and in the interval period were studied. Outcome was measured by expulsion rate, continuation rate, and incidence of dysfunctional uterine bleeding (DUB), Pelvic inflammatory disease (PID), failure rate and effect on puerperium.Results: Expulsion rate in PPIUCD group was 8.75% while in interval IUCD group it was 1.25%. Continuation rate following Postpartum intrauterine contraceptive device (PPIUCD) and interval IUCD insertion was 86.25% and 95% respectively. Incidence of bleeding per vaginum (menorrhagia) was 7.5% in PPIUCD group while 8.75% in interval IUCD group. There was one case 1.25% of PID in interval IUCD group while no case in PPIUCD was noted. Failure rate was nil in both the group. There was no effect on puerperium following PPIUCD insertion group during present study.Conclusions: PPIUCD is an effective and safe spacing method of contraception as compared to interval IUCD insertion. There is no statistically significant change in incidence of expulsion rate, continuation rate and other complications in both the group.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA