Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 86
Filtrar
1.
Bol. méd. Hosp. Infant. Méx ; 80(4): 247-252, Jul.-Aug. 2023. tab
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1520286

RESUMO

Abstract Background: Acute fetal distress (AFD) is a condition that requires timely diagnosis because it generates hypoxia, acidosis, and even intrauterine death. This study aimed to determine lactate and pH values in the umbilical cord in full-term newborns (NBs) with a history of AFD. Methods: We conducted a cross-sectional study in full-term NBs of mothers with at least one perinatal, neonatal, or gasometric AFD antecedent. Neonatal morbidity was considered: if 1-min Apgar ≤ 6, or advanced neonatal maneuvers, or neonatal intensive care unit (NICU) admissions were necessary. The cutoff points were lactate > 4mmol/L and pH < 7.2. Results: Of 66 NBs, 33.3% of mothers presented at least one antecedent for developing AFD; 22.7% presented hypertensive pregnancy disease, 13.6% oligohydramnios, and 63.6% other factors. Perinatally, 28.7% required advanced neonatal resuscitation maneuvers and 7.5% admission to the NICU. In the gasometry, the lactate and pH values for the neonatal morbidity of the NBs' group were 4.726 ± 1.401 and 7.293 ± 0.056, respectively, versus 2.240 ± 0.318 and 7.359 ± 0.022 (p < 0.05) for the group without associated neonatal morbidity. Conclusions: Lactate values in the umbilical cord increased by 25%, and pH decreased by one percent in NBs with a history of AFD and associated morbidity.


Resumen Introducción: El sufrimiento fetal agudo (SFA) es una condición que amerita un diagnóstico oportuno debido a que genera hipoxia, acidosis e incluso la muerte intrauterina. El objetivo de este estudio fue determinar los valores de lactato y pH en cordón umbilical en recién nacidos de término con antecedente SFA. Métodos: Se llevó a cabo un estudio transversal, en recién nacidos a término, de madres que tuvieron al menos un antecedente para SFA de tipo perinatal, neonatal o gasométrico. Se consideró morbilidad neonatal cuando presentaron Apgar al minuto ≤ 6, o requirieron maniobras avanzadas de reanimación neonatal, o ingreso a Unidad de Cuidados Intensivos Neonatales (UCIN). El punto de corte fue > 4 mmol/L para los valores de lactato y pH < 7.2. Resultados: De un total de 66 recién nacidos, el 33.3% de las madres presentaron al menos un antecedente para desarrollar SFA; el 22.7% presentó enfermedad hipertensiva del embarazo, el 13.6%, oligohidramnios, y el 63.6%, otros factores. El 28.7% requirieron maniobras avanzadas de la reanimación neonatal y el 7.5%, el ingreso a la UCIN. En la gasometría, el valor de lactato y pH para el grupo de recién nacidos con morbilidad neonatal fue de 4.726 ± 1.401 y 7.293 ± 0.056 respectivamente, versus 2.240 ± 0.318 y 7.359 ± 0.022 (p < 0.05) para el grupo sin morbilidad neonatal asociada. Conclusiones: Se observó un incremento del 25% de los valores de lactato en cordón umbilical y una disminución del 1% del pH en los recién nacidos con antecedente de SFA y morbilidad asociada.

2.
Gac. méd. Méx ; 159(2): 132-137, mar.-abr. 2023. tab
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1430396

RESUMO

Resumen Antecedentes: En México es exigua la evidencia sobre la exposición prenatal a metales. Objetivo: Estimar la concentración de arsénico, cadmio, manganeso y plomo en sangre de cordón umbilical (SCU), y su asociación con las concentraciones en sangre materna durante el embarazo y parto. Material y métodos: Se analizó la concentración de los metales en sangre materna durante el embarazo (n = 901), parto (n = 732) y en la SCU (n = 512) de participantes de la cohorte PROGRESS, residentes en la Ciudad de México. Se estimó la asociación entre la concentración en SCU y los biomarcadores maternos mediante modelos lineales generalizados, ajustados por covariables relevantes. Resultados: La media (μg/L) de plomo, arsénico y manganeso en SCU fue 27.14 (25.28-29.14), 0.77 (0.71-0.84) y 42.60 (40.45-44.83), respectivamente. El valor del cadmio no se pudo estimar porque 86.2 % de las mediciones fueron inferiores al límite de detección. Las concentraciones de plomo y manganeso en SCU se asociaron significativamente a los biomarcadores maternos durante el embarazo y el parto; solo se observó asociación con arsénico en el parto. Conclusiones: La exposición prenatal a metales tóxicos en periodos sensibles de la organogénesis evidencia un problema de salud pública desatendido. Se requiere un biomonitoreo poblacional y establecer regulación dirigida a proveer atención a población vulnerable.


Abstract Background: In Mexico, there is a paucity of evidence on the magnitude of prenatal exposure to metals. Objective: To estimate the concentration of arsenic, cadmium, manganese and lead in umbilical cord blood (UCB) and its association with maternal blood concentrations during pregnancy and delivery. Material and methods: Metal concentration in maternal blood was analyzed during pregnancy (n = 901), delivery (n = 732) and in UCB (n = 512) from participants of the PROGRESS cohort residing in Mexico City. The association between concentrations in UCB and maternal biomarkers was analyzed using generalized linear models, adjusted for relevant covariates. Results: Mean concentrations (μg/L) of lead, arsenic and manganese in UCB were 27.14 (25.28-29.14), 0.77 (0.71-0.84) and 42.60 (40.45-44.83), respectively. Cadmium concentration could not be estimated because 86.2% of measurements were below the detection limit. Lead and manganese concentrations in UCB were significantly associated with maternal biomarkers during pregnancy and delivery; at delivery, association was only observed with arsenic. Conclusions: Prenatal exposure to toxic metals in sensitive periods of organogenesis shows a neglected public health problem. Biomonitoring of the population and establishment of regulations aimed at providing care to vulnerable populations is required.

3.
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1515508

RESUMO

La afección vasa previa es un hallazgo prenatal raro y poco frecuente de hemorragia en la segunda mitad del embarazo, en la que los vasos umbilicales desprovistos de la gelatina de Wharton se interponen entre la presentación fetal y el orificio cervical interno. Cuando no se la detecta y se produce la rotura de los vasos, se asocia a una alta tasa de mortalidad perinatal. Se describen 3 tipos; el caso presentado se trata de vasa previa de tipo 1 secundaria a inserción velamentosa de cordón. Fue diagnosticada prenatalmente mediante ecografía por vía transvaginal asociada a Doppler color. Se practicó una cesárea con evolución materno perinatal favorable.


Vasa previa is a rare and infrequent prenatal finding of hemorrhage in the second half of pregnancy, in which umbilical vessels devoid of Wharton's jelly interpose between the fetal presentation and the internal cervical os. When undetected and rupture of the vessels occurs, it is associated with a high perinatal mortality rate. Three types are described; the case presented is type 1 vasa previa secondary to velamentous insertion of the cord. It was diagnosed prenatally by transvaginal ultrasound associated with color Doppler. A cesarean section was performed with favorable maternal and perinatal evolution.

4.
Rev. Fac. Med. UNAM ; 65(6): 20-25, nov.-dic. 2022. graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1431348

RESUMO

Resumen Las anomalías del cordón umbilical están asociadas a efectos adversos durante el embarazo. El nudo verdadero del cordón umbilical está presente en el 0.3-2.1% de los embarazos y se ha asociado a muerte fetal. Dentro de los factores de riesgo se incluye, la edad materna, índice de masa corporal (IMC) elevado, multiparidad, trastornos hipertensivos, tabaquismo, polihidramnios, diabetes gestacional, sexo masculino del feto y otras malformaciones. El diagnóstico prenatal del nudo verdadero es raro y un desafío. La mayoría se diagnostica durante el nacimiento y sólo el 0.08% de los nudos verdaderos son diagnosticados de manera prenatal. El registro cardiotocográfico puede registrar trazos no tranquilizadores que reflejan que hay un estrés hipóxico o mecánico que interrumpe la oxigenación fetal. El objetivo de este reporte es mostrar un caso de nudo verdadero del cordón umbilical que presentó taquicardia fetal persistente durante el trabajo de parto con terminación del embarazo vía vaginal.


Abstract Umbilical cord abnormalities are associated with adverse effects during pregnancy. The true umbilical cord knot is present in 0.3-2.1% of pregnancies and has been associated with fetal death. Risk factors include maternal age, high BMI, multiparity, hypertensive disorders, smoking, polyhydramnios, gestational diabetes, male sex of the fetus, and other malformations. Prenatal diagnosis of the true knot is rare and challenging. Most are diagnosed at birth and only 0.08% of true knots are diagnosed prenatally. Non-reassuring cardiotocography traces may be present, reflecting hypoxic or mechanical stress disrupting fetal oxygenation. The aim of this case report is to present a case of true umbilical cord knot presenting with persistent fetal tachycardia during labor, resolved by vaginal delivery.

5.
Prensa méd. argent ; 108(8): 407-411, 20220000. fig
Artigo em Espanhol | LILACS, BINACIS | ID: biblio-1410704

RESUMO

Se presenta un caso clínico de diagnóstico ecográfico de hernia diafragmática realizado a partir de signos de sospecha. La paciente se presenta a control prenatal cursando 18 semanas de gestación, donde se visualiza alteración de la posición de la silueta cardiaca y cambios en la ecogenicidad en el campo pulmonar izquierdo. Se evalúan los signos pronósticos de las hernias diafragmáticas como la presencia de estómago e hígado en tórax y se calcula el índice pulmóncabeza ( LHR). En el presente caso el LHR arrojo un valor de 2,3 %, lo cual indica un buen pronóstico ya que el LHR mayor a 1,4 % se asocia a 93 % de posibilidades de sobrevivir


A clinical case of ultrasound diagnosis of diaphragmatic hernia performed from signs of suspicion is presented. The patient is presented to prenatal control studying 18 weeks gestation, where alteration of the position of the cardiac silhouette and changes in ecogenicity in the left pulmonary field is displayed. The prognostic signs of diaphragmatic hernias such as the presence of stomach and thorax liver and the lung-headed index (LHR) are evaluated. In the present case, the LHR shows a value of 2.3 %, which indicates a good prognosis since the LHR greater than 1.4 % is associated with 93 % possibilities to survive


Assuntos
Humanos , Feminino , Gravidez , Cuidado Pré-Natal , Cordão Umbilical , Hérnia Diafragmática/diagnóstico
6.
Rev. Fac. Med. UNAM ; 65(4): 30-37, jul.-ago. 2022. tab, graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1394633

RESUMO

Resumen El nudo verdadero de cordón umbilical es una patología con una incidencia relativamente baja. Se asocia a riesgo de pérdida del bienestar fetal y muerte perinatal. Existen factores de riesgo tanto maternos como fetales, con diferentes resultados perinatales asociados. El diagnóstico prenatal es un reto para el obstetra y la mayoría de casos son hallazgos al nacimiento, sin embargo, hoy en día se dispone de métodos ecográficos para su búsqueda intencionada, principalmente en pacientes con factores de riesgo. De igual forma debe sospecharse ante la presencia de un registro cardiotocográfico no tranquilizante, sobre todo cuando no existe respuesta a las maniobras habituales de reanimación intrauterina, como la posición en decúbito lateral izquierdo, oxígeno suplementario e hidratación materna. El objetivo del presente reporte es describir 4 casos de nudo verdadero en embarazos a término en un hospital de tercer nivel, en donde se estimó una incidencia del 0.03%, con una edad gestacional promedio de 39.3 semanas y una media de edad materna de 32.2 años. Los principales hallazgos intraparto fueron alteraciones en el registro cardiotocográfico, tales como desaceleraciones variables y tardías. La resolución del embarazo fue por vía vaginal en 2 de las pacientes, mientras que las otras 2 se resolvieron mediante cesárea. Se registró un caso de muerte perinatal.


Abstract The true umbilical cord knot is a pathology with an incidence relatively low. It is associated with the risk of loss of fetal well-being and stillbirth. There are both maternal and fetal risk factors, with different associated perinatal outcomes. Prenatal diagnosis of a true knot is a diagnostic challenge for the obstetrician, however, nowadays it is possible by ultrasound for incidental finding or by intentional search, mainly in patients with risk factors. In the same way it should be suspected in the presence of a non-reassuring cardiotocography, especially when there is no response to the usual intrauterine resuscitation maneuvers, such as left lateral decubitus position, supplemental oxygen and maternal hydration. The purpose of this report is to describe 4 cases of true knot in term pregnancies, in a third level hospital, where an incidence of 0.03% was estimated,, with a mean gestational age of 39.3 weeks and a mean maternal age of 32.2 years. The main intrapartum findings were alterations in the cardiotocography, such as variable and late decelerations. The route of pregnancy resolution was equitable among the patients, 2 were resolved by vaginal delivery and the other 2 by cesarean section. Pregnancy was resolved by vaginal delivery in 2 of the patients, while the other 2 were resolved by cesarean section. One case of stillbirth was registered

7.
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1424329

RESUMO

A propósito de la presentación de un caso de embarazo gemelar monocoriónico monoamniótico, se revisó la literatura sobre su diagnóstico y manejo mediante búsqueda electrónica en la base de datos de Medline, OVID, Cochrane y PubMed entre los años 1966 y 2019. Las palabras clave utilizadas en la indagación fueron: embarazo, gemelos, monoamniótico, enredamiento de cordones. Existe un riesgo alto de muerte fetal súbita en gemelos monoamnióticos causado por el enredamiento de los cordones umbilicales, por lo que el diagnóstico oportuno de la corionicidad y amnionicidad en el embarazo gemelar mediante ecografía puede dar la pauta para una vigilancia fetal estrecha y mejorar así el resultado obstétrico.


In view of the presentation of a case of monochorionic monoamniotic twin pregnancy, the literature on its diagnosis and management was reviewed by electronic search in the Medline, OVID, Cochrane, and PubMed databases between 1966 and 2019. The key words used in the inquiry were: pregnancy, twins, monoamniotic, cord entanglement. There is a high risk of sudden fetal death in monoamniotic twins caused by entanglement of the umbilical cords, so timely diagnosis of chorionicity and amnionicity in twin pregnancy by ultrasonography may provide guidance for close fetal surveillance and thus improve obstetric outcome.

8.
Rev. chil. obstet. ginecol. (En línea) ; 87(2): 158-161, abr. 2022. ilus
Artigo em Espanhol | LILACS | ID: biblio-1388722

RESUMO

Resumen La torsión del cordón umbilical como causa de muerte fetal es rara, con pocos casos reportados. No se conoce con claridad la causa y se presenta principalmente en el segundo trimestre de embarazo. Los factores de riesgo descritos son la longitud del cordón umbilical y el aumento del número de giros. Se reporta el caso de una paciente de 37 años, grávida 2, para 1 con embarazo de 23 semanas, con hallazgo ecográfico de muerte fetal. En el estudio de histopatología se evidenció el cordón umbilical con hiperenrollamiento y torsión a nivel de la unión feto-umbilical con oclusión de la luz de los vasos umbilicales como causa de muerte fetal. Se requiere la investigación de esta patología para determinar los factores de riesgo y el riesgo de recurrencia en futuros embarazos con el fin de establecer métodos de vigilancia fetal antenatal.


Abstract Torsion of the umbilical cord as a cause of fetal death is a rare occurrence, with few reported cases. The cause is not clearly known, and it transpires mainly in the second trimester of pregnancy; the risk factors described are the length of the umbilical cord with increased number of twists. The case of a 37-year-old woman is reported, gravida 2 para 1, 23 weeks pregnant with ultrasound diagnosis of fetal death. Histopathology revealed hypercoiled umbilical cord torsion at the point where the umbilical cord attaches to the fetus, with occlusion of the lumen of the umbilical vein, as a cause of fetal death. Further research of this pathology is required to determine the risk factors and risk of recurrence in future pregnancies that will allow the preparation of antenatal fetal surveillance methods.


Assuntos
Humanos , Feminino , Gravidez , Adulto , Anormalidade Torcional/complicações , Cordão Umbilical/patologia , Morte Fetal/etiologia
9.
Rev. gaúch. enferm ; 43: e20210245, 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BDENF | ID: biblio-1409371

RESUMO

ABSTRACT Objective: To develop and validate clinical simulation scenario for teaching women in their puerperium and their families about care for the newborn's umbilical cord stump. Method: Methodological study in two stages: 1 - elaboration of the checklist of the procedure for cleaning the umbilical cord and of the clinical case; and 2 - development of the simulated scenario. A Content Validity Index of 0.8 was adopted as the valid range of agreement. Results: After validation, the case was validated, being approved by 100% of the experts. All items of the simulation scenario obtained agreement scores above 0.91. Conclusion: The validated scenario can be used in different contexts: teaching of Neonate Nursing, training teams, and teaching women in their puerperium and their families, who were the target of the study. Considering the benefits of simulation, we believe the simulation here will contribute to better and safer care.


RESUMEN Objetivo: Desarrollar y validar un escenario de simulación clínica para enseñar a las puérperas y sus familias sobre cuidado con el cordón umbilical del recién nacido. Método: Estudio metodológico en dos fases: 1 - construcción de un checklist para el procedimiento de limpieza del muñón del cordón umbilical y elaboración del caso; 2 - desarrollo del escenario simulado. Se adoptó un Índice de Validez de Contenido del 0,8 o mayor como relevante para concordancia. Resultados: Luego de la construcción del caso, la validación fue aprobada por el 100% de los expertos. Todos los ítems del escenario de simulación obtuvieron puntajes de concordancia superiores a 0.91. Conclusión: El escenario validado puede ser utilizado en diferentes contextos: enseñanza de Enfermería Neonatal, entrenamiento de equipos, o aprendizaje de las puérperas y sus familias, que fue el objetivo del estudio. Considerando los beneficios de la simulación, creemos en su contribución para una atención mejor y más segura.


RESUMO Objetivo: Desenvolver e validar cenário de simulação clínica para ensino de puérperas e familiares sobre cuidados com o coto umbilical do recém-nascido. Método: Estudo metodológico em duas fases: 1 - construção de checklist do procedimento de higienização do coto umbilical, elaboração e validação semântica do caso clínico com 11 experts em simulação e área materno-infantil; 2 - desenvolvimento e validação do cenário junto a 11 experts em simulação e em neonatologia/pediatria. O Índice de Validade de Conteúdo de 0,8 foi adotado como relevante alcance de concordância. Resultados: Após construção do caso, realizou-se validação, aprovada por 100% dos experts. Todos itens do cenário simulado obtiveram escores de concordância superiores a 0,91. Conclusão: O cenário validado pode ser utilizado em diferentes contextos: ensino da Enfermagem Neonatal, capacitação de equipes e, aprendizagem de puérperas e familiares, alvos do estudo. Vistos benefícios da simulação, acredita-se na sua contribuição para melhoria assistencial e cuidado seguro.

10.
Artigo em Inglês | LILACS-Express | LILACS, BDENF | ID: biblio-1447813

RESUMO

Objective: To map the available evidence on umbilical cord milking in newborns. Material and Method: Scoping Review based on the protocol proposed by the Joanna Briggs Institute. A search for full-text articles published in MEDLINE, SCOPUS, WOS and CINAHL was carried out using the following keywords: infant, newborn, umbilical cord milking, placental transfusion and umbilical cord blood. Results: The results indicated umbilical cord milking has superior benefits to the immediate cord clamping, among the main ones are higher levels of Hemoglobin, Hematocrit and Serum Ferritin, and reduction of complications in preterm newborns, such as intraventricular hemorrhage and the need for blood transfusion. When compared to delayed cord clamping, it has similar benefits, but milking is considered a faster method of placental blood transfusion. Conclusions: Umbilical cord milking has similar potential to delayed cord clamping. Therefore, it can be an alternative for obstetric nurses and midwives when delayed cord clamping cannot be performed in order to ensure the benefits of placental transfusion to the neonate.


Objetivo: Mapear la evidencia disponible sobre la ordeña del cordón umbilical en recién nacidos. Material y Método: Revisión de Alcance con base en el protocolo propuesto por el Instituto Joanna Briggs. Se realizó una búsqueda de artículos de texto completo publicados en MEDLINE, SCOPUS, WOS y CINAHL utilizando las siguientes palabras clave: lactante, recién nacidos, ordeña cordón umbilical, transfusión placentaria y sangre de cordón umbilical. Resultados: La ordeña del cordón umbilical tiene beneficios superiores al pinzamiento inmediato del cordón, entre los principales se encuentran: mayores niveles de hemoglobina, hematocrito y ferritina sérica y reducción de complicaciones en recién nacidos prematuros, tales como hemorragia intraventricular y necesidad de transfusión sanguínea. En comparación con el pinzamiento tardío del cordón, tiene beneficios similares, pero la ordeña se considera el método más rápido de transfusión de sangre placentaria. Conclusiones: La ordeña del cordón umbilical tiene potencial similar al pinzamiento tardío del cordón, por lo tanto, puede ser una alternativa para enfermeras obstétricas y parteras cuando no se puede realizar el pinzamiento tardío del cordón para asegurar los beneficios de la transfusión placentaria al neonato.


Objetivo: Mapear as evidências disponíveis sobre a ordenha de cordão umbilical em recém-nascidos. Material e Método: Revisão de escopo baseada no protocolo proposto pelo Joanna Briggs Institute. A busca de artigos completos publicados na MEDLINE, SCOPUS, WOS e CINAHL foi realizada utilizando as seguintes palavras-chave: lactente, recém-nascido, ordenha do cordão umbilical, transfusão de placenta e sangue do cordão umbilical. Resultados: Os resultados indicaram que a ordenha do cordão umbilical tem benefícios superiores ao clampeamento imediato do cordão, entre os principais estão: níveis mais elevados de hemoglobina, hematócrito e ferritina sérica e redução de complicações em recém-nascidos pré-termo, como hemorragia intraventricular e necessidade de transfusão sanguínea. Quando comparado ao clampeamento tardio do cordão umbilical, tem benefícios semelhantes, mas a ordenha é considerada um método mais rápido de transfusão de sangue da placenta. Conclusões: A ordenha do cordão umbilical tem potencial semelhante ao clampeamento tardio do cordão umbilical, portanto, pode ser uma alternativa às enfermeiras obstetras e parteiras quando o clampeamento tardio do cordão não pode ser executado a fim de garantir os benefícios da transfusão placentária ao neonato.

11.
Rev. Esc. Enferm. USP ; 56: e20210423, 2022. tab, graf
Artigo em Inglês, Português | LILACS, BDENF | ID: biblio-1365414

RESUMO

ABSTRACT OBJECTIVE: To identify factors associated with umbilical cord clamping in term newborns and to compare the recording of clamping time in the medical record with what was observed. METHOD: Cross-sectional study, with 300 mothers-infants, in a university hospital. Clamping time and medical records were observed, and a structured questionnaire was applied to postpartum women for sociodemographic variables. Bivariate analysis, multivariate Poisson Regression model, and Kappa concordance test were performed. RESULTS: The percentage of late/optimal clamping observed was 53.7%. The associated factors were skin-to-skin contact in the delivery room (PR = 0.76; 0.61-0.95; p = 0.014), position of the newborn below the vaginal canal (PR = 2.6; CI95%: 1.66-4.07; p < 0.001), position of the newborn at the vaginal level (PR = 2.03; CI95%: 1.5-2.75; p < 0.001), and need for newborn resuscitation in the delivery room (PR = 1.42; CI95%; 1.16-1.73; p = 0.001). Kappa concordance level of the professionals, records compared to the observation was: nurse 0.47, obstetrician 0.59, and pediatrician 0.86. CONCLUSION: the identification of associated factors and the comparison between recording and observing the clamping time can help in the planning and implementation of improvements for adherence to good practices at birth.


RESUMEN Objetivo: Identificar factores asociados al clampaje del cordón umbilical en neonatos a término y comparar el registro del tiempo de clampaje en el prontuario con el observado. Método: Estudio transversal, con 300 madres-hijos, en hospital universitario. Se observó tiempo de clampaje y registros en prontuario, siendo aplicado cuestionario estructurado a las puérperas para variables sociodemográficas. Se utilizó análisis bivariado, modelo de Regresión de Poisson multivariado e índice de concordancia Kappa. Resultados: el porcentaje de clampaje tardío/oportuno observado fue 53,7%. Los factores asociados fueron contacto piel con piel en sala de partos (RP = 0,76; 0,61-0,95; p = 0,014), posición del recién nascido abajo del canal vaginal (RP = 2,6; IC95%: 1,66-4,07; p < 0,001), posición del recién nacido en el nivel vaginal (RP = 2,03; IC95%: 1,5-2,75; p < 0,001) y necesidad de reanimación del recién nacido en sala de partos (RP = 1,42; IC95%; 1,16-1,73; p = 0,001). El nivel de concordancia Kappa del registro de los profesionales comparado a la observación fue: enfermera 0,47, obstetra 0,59 y pediatra 0,86. Conclusión: la identificación de los factores asociados y la comparación entre registro y observación del tiempo de clampaje puede auxiliar en la planificación e implementación de mejorías para la adhesión a las buenas prácticas de nacimiento.


RESUMO Objetivo: identificar fatores associados ao clampeamento do cordão umbilical em neonatos a termo e comparar o registro do tempo de clampeamento no prontuário com o observado. Método: estudo transversal, com 300 mães-bebês, em hospital universitário. Observaram-se tempo de clampeamento e registros em prontuário, sendo aplicado questionário estruturado às puérperas para variáveis sociodemográficas. Procedeu-se análise bivariada, modelo de Regressão de Poisson multivariado e teste de concordância Kappa. Resultados: o percentual de clampeamento tardio/oportuno observado foi 53,7%. Os fatores associados foram contato pele-a-pele em sala de parto (RP = 0,76; 0,61-0,95; p = 0,014), posição do recém-nascido abaixo do canal vaginal (RP = 2,6; IC95%: 1,66-4,07; p < 0,001), posição do recém-nascido no nível vaginal (RP = 2,03; IC95%: 1,5-2,75; p < 0,001) e necessidade de reanimação do recém-nascido em sala de parto (RP = 1,42; IC95%; 1,16-1,73; p = 0,001). O nível de concordância Kappa do registro dos profissionais comparado à observação foi: enfermeira 0,47, obstetra 0,59 e pediatra 0,86. Conclusão: a identificação dos fatores associados e a comparação entre registro e observação do tempo de clampeamento podem auxiliar no planejamento e implementação de melhorias para adesão às boas práticas no nascimento.


Assuntos
Cordão Umbilical , Neonatologia , Recém-Nascido , Registros , Enfermagem Obstétrica , Obstetrícia
12.
Arch. argent. pediatr ; 119(4): e315-e321, agosto 2021. tab
Artigo em Inglês, Espanhol | LILACS, BINACIS | ID: biblio-1281006

RESUMO

La prematiridad fue aumentando la supervivencia desde hace varios años, y eso produce, sobre todo, una preocupación en los prematuros nacidos antes de las 28 semanas de gestación. El tiempo del clampeo del cordón umbilical puede generar diversos trastornos, principalmente, cuando se realiza temprano (10-15 segundos). Ya desde hace 20 años, a través de varias investigaciones, se pudieron demostrar los notorios beneficios del clampeo demorado del cordón (de 2 a 3 minutos). Esta práctica fue instalada en la asistencia obstétrica y neonatal por las recomendaciones de sociedades científicas y de las revisiones sistemáticas, que señalaron las sólidas evidencias que apoyaban esta conducta para prematuros. En esta revisión, se describen los artículos más relevantes en los últimos años, que sustentan notoriamente la aplicación del clampeo demorado del cordón versus el clampeo temprano. Asimismo, esta práctica genera una disminución de los trastornos graves en prematuros.


For several years now, the survival of preterm infants has been increasing, which has shifted our concern to preterm infants born before 28 weeks of gestation in particular. The timing of umbilical cord clamping may lead to several disorders, especially when done early (10-15 seconds). In the last two decades, several investigations have shown the considerable benefits of delayed cord clamping (2-3 minutes). Delayed cord clamping has been practiced in obstetrics and neonatal care based on the recommendations made by scientific societies and in systematic reviews, which have provided solid evidence to support this practice in preterm infants. This review describes the most relevant articles from the last years, which strongly support the use of delayed cord clamping versus early cord clamping. In addition, this practice reduces the rate of severe disorders in preterm infants.


Assuntos
Humanos , Masculino , Feminino , Gravidez , Recém-Nascido , Cordão Umbilical , Circulação Placentária/fisiologia , Ligadura , Fatores de Tempo , Recém-Nascido Prematuro
13.
Multimed (Granma) ; 25(4): e2218, 2021. graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1287431

RESUMO

RESUMEN Introducción: los nudos verdaderos del cordón umbilical son poco frecuentes y ocurren entre 0.3-1.3 % de todos los embarazos. La tasa de mortalidad fetal antes del parto oscila entre 4 a 10 veces mayor con relación a los embarazos con cordones umbilicales normales. Presentación de caso: caso 1 paciente de 39 años de edad G3 P (1eut y 1 ces) A0, obesa, edad gestacional de 39.3 semanas, que asiste al Hospital con contracciones uterinas de 3/10 minutos, buena intensidad, presentación alta, cefálica y la frecuencia cardiaca fetal(fcf) de 164/minutos, cesárea anterior hace 2 años, signo de más, con cuello uterino permeable 1cm, grueso y membranas intactas. Caso 2: paciente que ingresa en el Hospital con 41 años de edad, obesa, con G5 P4 A0, Edad gestacional de 40, 4 semanas, el último parto ocurrió hace 6 años, posee contracciones 2/10 minutos y fcf de 160/minutos, con desaceleraciones tardías en los registros cardiotocográficos (CTG), dilatación de 2cms con membranas intactas y el cuello grueso y rígido. TA: 140/80, en hipertensa crónica y tratamiento con metildopa 250mg c/6hrs. Caso 3: paciente que ingresa con 39 años de edad, 41 semanas de gestación, G6 P5 A0, obesa, el último parto se realizó con la aplicación de fórceps con apgar bajo, hace 3 años, lleva tratamiento con metildopa 500mg cada 8 horas por ser una hipertensa crónica; ingresó con tensión arterial de 120/80, se queja de dolores bajo vientre. Discusión: dentro de los factores de riesgos planteados en la aparición de los nudos verdaderos del cordón umbilical se constató: la hipertensión arterial crónica en los tres pacientes, dos multíparas, tres con edad igual o mayor a 39 años y todos con cordones mayores a 60cms. La longitud normal del cordón es de (30cms a 60cms). Se plantea como riesgo de desarrollar nudos del cordón, con cordones mayores a 80cms. Conclusiones: no hubo complicaciones para la salud de los neonatos.


ABSTRACT Introduction: true umbilical cord knots are rare and occur between 0.3-1.3 % of all pregnancies. The fetal mortality rate before delivery ranges from 4 to 10 times higher than in pregnancies with normal umbilical cords. Case presentation: case 1 39-year-old patient G3 P (1 eut and 1 ces) A0, obese, gestational age of 39.3 weeks, who attends the Hospital with uterine contractions of 3/10 minutes, good intensity, high presentation, cephalic and fetal heart rate (fcf) of 164 / min, previous cesarean section 2 years ago, plus sign, with a patent cervix 1cm, thick and intact membranes. Case 2: patient admitted to the Hospital at 41 years of age, obese, with G5 P4 A0, gestational age of 40, 4 weeks, the last delivery occurred 6 years ago, has contractions 2/10 minutes and fcf of 160 / minutes, with late decelerations in the cardiotocographic recordings (CTG), dilation of 2 cm with intact membranes and a thick and stiff neck. BP: 140/80, in chronic hypertensive and treatment with methyldopa 250mg every 6hrs. Case 3: patient who was admitted with 39 years of age, 41 weeks of gestation, G6 P5 A0, obese, the last delivery was performed with the application of forceps with low apgar, 3 years ago, has been treated with methyldopa 500mg every 8 hours for be a chronic hypertensive; she was admitted with a blood pressure of 120/80, she complains of pain in the lower abdomen. Discussion: among the risk factors raised in the appearance of true umbilical cord knots, it was found: chronic arterial hypertension in the three patients, two multiparous, three with age equal to or greater than 39 years and all with cords greater than 60 cm. The normal length of the cord is (30cms to 60cms). It is posed as a risk of developing knots in the cord, with cords greater than. Conclusions: there were no complications for the health of the neonates.


RESUMO Introdução: os nós verdadeiros do cordão umbilical são raros e ocorrem entre 0,3-1,3% de todas as gestações. A taxa de mortalidade fetal antes do parto varia de 4 a 10 vezes maior do que em gestações com cordão umbilical normal. Apresentação do caso: caso 1 paciente G3 P, 39 anos (1 eut e 1 ces) A0, obesa, idade gestacional de 39,3 semanas, que chega ao Hospital com contrações uterinas de 3/10 minutos, boa intensidade, apresentação elevada, frequência cardíaca cefálica e fetal (fcf) de 164 / min, cesárea anterior há 2 anos, sinal positivo, com colo pérvio 1cm, membranas espessas e íntegras. Caso 2: paciente que dá entrada no Hospital com 41 anos de idade, obeso, com G5 P4 A0, idade gestacional de 40,4 semanas, último parto há 6 anos, contrações 2/10 minutos e fcf de 160 / minutos, com desacelerações tardias nos registros cardiotocográficos (CTG), dilatação de 2 cm com membranas íntegras e pescoço grosso e rígido. PA: 140/80, em hipertensos crônicos e tratamento com metildopa 250mg a cada 6h. Caso 3: paciente que deu entrada com 39 anos, 41 semanas de gestação, G6 P5 A0, obesa, último parto realizado com aplicação de fórceps com baixo apgar, há 3 anos, tratou com metildopa 500mg a cada 8 horas para ser hipertenso crônico; Foi internado com pressão arterial de 120/80, com queixa de dores na região abdominal inferior. Discussão: entre os fatores de risco levantados no aparecimento de nós verdadeiros do cordão umbilical, encontrou-se: hipertensão arterial crônica nos três pacientes, dois multíparos, três com idade igual ou superior a 39 anos e todos com cordões maiores que 60 cm. O comprimento normal do cabo é (30 cms a 60 cms). É considerado risco de desenvolvimento de nós no cordão, com cordões maiores que 80cms. Conclusões: não houve complicações para a saúde dos neonatos.

14.
Alerta (San Salvador) ; 4(3): 102-98, jul. 29, 2021. ilus
Artigo em Espanhol | LILACS, BISSAL | ID: biblio-1282073

RESUMO

El síndrome de cordón umbilical corto es una anomalía poco común e incompatible con la vida que se asocia a defectos de la pared anterior del feto, cordón umbilical corto o ausente y anomalías de los miembros. Esta entidad es la más severa y más infrecuente entre los defectos de la pared anterior del abdomen, con una incidencia de 1 en 14 000 nacimientos. Se presenta el caso de un recién nacido de término, de sexo indeterminado, producto de primer embarazo, de parto abdominal. A las 28 semanas de gestación se diagnosticó un defecto en pared abdominal anterior y una imagen quística de columna vertebral por ultrasonografía. Al nacimiento se observaron los órganos abdominales expuestos, el cordón umbilical grueso, de 10 cm de longitud, eventración de intestinos e hígado y cifoescoliosis marcada, ausencia de genitales externos y de ano, un remanente de miembro inferior derecho y miembro inferior izquierdo completo con pie equinovaro. Se le dio apoyo ventilatorio y falleció a los 15 minutos de vida


Short umbilical cord syndrome is a rare and life-incompatible abnormality associated with fetal anterior wall defects, absent or short umbilical cord, and limb abnormalities. This entity is the most severe and rarest of anterior abdominal wall defects, with an incidence of 1 in 14,000 births. We present the case of a full-term newborn, of undetermined sex, product of first pregnancy, of abdominal delivery. At 28 weeks' gestation, an anterior abdominal wall defect and a cystic image of the spine were diagnosed by ultrasonography. At birth, the exposed abdominal organs, the thick umbilical cord, 10 cm in length, eventration of the intestines and liver and marked kyphoscoliosis, absence of external genitalia and anus, a remnant of the right lower limb and complete left lower limb with foot were observed. equinovarus. Ventilatory support was given and died at 15 minutes of life


Assuntos
Síndrome , Cordão Umbilical , Parto , Intestinos
15.
Cienc. Salud (St. Domingo) ; 5(2): [45-55], Ene-Abr. 2021. tab
Artigo em Espanhol | LILACS | ID: biblio-1291442

RESUMO

Introducción: las células madre mesenquimatosas (CMM) se diferencian de diversos tipos celulares para la regeneración de tejidos, esta característica sumada con la versatilidad del antígeno leucocitario humano (HLA) representan una eficaz alternativa para el tratamiento de enfermedades con tejidos deteriorados. Se pueden obtener a partir de médula ósea, cordón umbilical (CU) y sangre fetal. Objetivo: analizar los tipos de diferenciación de las CMM, sus métodos de extracción y su relación con bancos de sangre de cordón umbilical (BSCU), a fin de demostrar la eficacia de las CMM, en patologías que impliquen alteración de algún tejido u órgano. Metodología: se revisaron varias publicaciones en español e inglés en Pubmed, Clinicalkey y Science Direct; desde 2013 hasta 2020. Se usaron los términos sangre fetal, células madre mesenquimatosas, trasplante de Células Madre de Sangre del Cordón Umbilical y bancos de sangre. Con dicha información se redactó un panorama amplio sobre las células mesenquimales y como estas participan en diversas áreas de la salud, con un énfasis importante en sus usos terapéuticos y lo referente a de donde provienen. Conclusión: a través de la pluripotencialidad de las CMM, se han podido emplear en múltiples patologías pues reestablece tejidos o líneas celulares exitosamente. Así mismo, los recursos para su obtención son claves en la tolerancia de los pacientes, por lo cual una gran opción para su obtención es el CU, que actualmente cuenta con bancos exclusivos para esto. (AU)


Introduction: mesenchymal stem cells (MSC) differentiate into multiple cell types for tissue regeneration, this characteristic added with the versatility of human leukocyte antigen (HLA) represent an effective alternative for the treatment of diseases with damaged tissues. They can be obtained from bone marrow, umbilical cord (UC), and fetal blood. Objetive: analyze the types of differentiation of MSC, their extraction methods and their relationship with umbilical cord blood banks (UCBB), in order to demonstrate the efficacy of MSC, in pathologies that involve alteration of a tissue or organ. Methodology: several publications in Spanish and English in Pubmed, Clinicalkey and Science Direct were reviewed; from 2013 to 2020. The terms fetal blood, mesenchymal stem cells, Umbilical Cord Blood Stem Cell transplantation and blood banks were used. With this information, a broad overview of mesenchymal cells and how they participate in various areas of health was drawn up, with an important emphasis on their therapeutic uses and where they come from. Conclusion: through the pluripotentiality of MSC, they have been used in multiple pathologies as it successfully re-establishes tissues or cell lines. Also, the resources for obtaining it are key in the tolerance of patients, which is why a great option for obtaining it is the UC, which currently has exclusive banks for this.


Assuntos
Células-Tronco Mesenquimais , Bancos de Sangue , Sangue Fetal
16.
Biomédica (Bogotá) ; 41(1): 8-16, ene.-mar. 2021. tab, graf
Artigo em Espanhol | LILACS | ID: biblio-1249054

RESUMO

Resumen. La encefalopatía hipóxico-isquémica es una causa frecuente e importante de daño neurológico en recién nacidos a término y prematuros. Un evento centinela de esta condición es la vasa previa, específicamente cuando existe anormalidad de la placenta como la inserción "velamentosa" del cordón umbilical. Algunos reportes evidencian la asociación entre estas dos condiciones, pero son escasos los que dan cuenta del proceso de recuperación y del pronóstico neurológico de los niños afectados por ellas. Se presenta el caso de un paciente, con antecedentes de inserción "velamentosa" del cordón umbilical y encefalopatía hipóxico-isquémica, que recibió hipotermia terapéutica (cool cap). Se describe su proceso de rehabilitación neurológica y se calculó el porcentaje de probabilidad de presentar esta condición frente a la población sin estos factores. El niño tenía cinco años y el puntaje en su prueba de Apgar fue de 0 al minuto y de 2 a los 15 minutos. Desarrolló encefalopatía hipóxico-isquémica grave secundaria a una inserción "velamentosa" del cordón umbilical sin diagnóstico prenatal, con gran compromiso neurológico y multisistémico inicial. El proceso de recuperación incluyó el manejo inicial multidisciplinario en la unidad de cuidados intensivos neonatales y el inicio temprano de habilitación neurológica. Hoy el niño está escolarizado y en terapia integral, no presenta deficiencias motoras ni sensoriales en el examen físico, aunque la prueba neuropsicológica sugiere un riesgo de trastorno por déficit de atención e hiperactividad. Habitualmente, los niños con encefalopatía hipóxico-isquémica grave presentan discapacidad por deficiencias motoras, cognitivas o conductuales. El haber recibido hipotermia terapéutica y un manejo estructurado de rehabilitación redujo en gran medida las deficiencias esperadas y ha promovido un satisfactorio desarrollo físico y neurológico.


Abstract. Hypoxic-ischemic encephalopathy is a frequent and important cause of neurological problems in term and preterm newborns. A sentinel event of this entity is the vasa previa, specifically when there is an abnormality of the placenta such as a velamentous cord insertion. Some reports have shown the association between these two entities, but those regarding the recovery process and the neurological prognosis of children with both conditions are scarce. We present the case of a patient with a history of velamentous cord insertion and hypoxic-ischemic encephalopathy who received therapeutic hypothermia (cool cap). We describe his neurological rehabilitation process and we calculated the percentage of probability of presenting this condition compared to the population without these factors. The patient was a five-year-old boy with an Apgar index at birth equal to zero at one minute and equal to two at fifteen minutes who developed severe hypoxic-ischemic encephalopathy secondary to a velamentous cord insertion without prenatal diagnosis and a marked initial neurological and multisystemic compromise. The recovery process included early multidisciplinary management in the neonatal intensive care unit and a focus on early neurological habilitation. The patient is currently in school and he undergoes comprehensive therapies; on physical examination, he presents no motor or sensory deficiencies. His neuropsychological test suggests the risk of attention deficit hyperactivity disorder. Children with severe hypoxic-ischemic encephalopathy usually have disabilities due to motor, cognitive, and/or behavioral deficiencies. Having received therapeutic hypothermia and a structured rehabilitation process greatly reduced the expected deficiencies according to prognosis and have promoted satisfactory physical and neurological development.


Assuntos
Cordão Umbilical , Hipóxia-Isquemia Encefálica , Hipotermia Induzida , Reabilitação Neurológica
17.
Gac. méd. Méx ; 157(1): 30-36, ene.-feb. 2021. tab, graf
Artigo em Espanhol | LILACS | ID: biblio-1279070

RESUMO

Resumen Introducción: Se requiere analizar diversos parámetros para el control de calidad adecuado de las unidades de sangre de cordón umbilical (USCU) cuando se utilizan con fines terapéuticos. Objetivo: Optimizar las unidades formadoras de colonias (UFC) de cultivos clonogénicos y detectar el genoma del virus del papiloma humano (VPH) en USCU. Métodos: Se incluyeron 141 muestras de sangre de cordón umbilical (SCU), de segmento y de UFC de cultivos clonogénicos de USCU. Se realizó extracción de ADN, cuantificación y amplificación por PCR del gen endógeno GAPDH. Se detectó el gen L1 del VPH con los oligonucleótidos MY09/MY11 y GP5/GP6+; los productos de PCR se migraron en electroforesis de agarosa. El ADN purificado de las UFC se analizó mediante electroforesis de agarosa y algunos ADN, con la técnica sequence specific priming. Resultados: La concentración de ADN extraído de UFC fue superior comparada con la de SCU (p = 0.0041) y la de segmento (p < 0.0001); así como la de SCU comparada con la de segmento (p < 0.0001). Todas las muestras fueron positivas para la amplificación de GAPDH y negativas para MY09/MY11 y GP5/GP6+. Conclusiones: Las USCU criopreservadas fueron VPH netativas; además, es factible obtener ADN en altas concentraciones y con alta pureza a partir de UFC de los cultivos clonogénicos.


Abstract Introduction: Analysis of several markers is required for adequate quality control in umbilical cord blood units (UCBU) when are used for therapeutic purposes. Objective: To optimize colony-forming units (CFU) from clonogenic cultures and to detect the human papillomavirus (HPV) genome in UCBU. Methods: One hundred and forty-one umbilical cord blood (UCB), segment or CFU samples from UCBU clonogenic cultures were included. DNA extraction, quantification and endogenous GAPDH gene PCR amplification were carried out. Subsequently, HPV L1 gene was detected using the MY09/MY11 and GP5/GP6+ oligonucleotides. PCR products were analyzed with electrophoresis in agarose gel. CFU-extracted purified DNA was analyzed by electrophoresis in agarose gel, as well as some DNAs, using the SSP technique. Results: CFU-extracted DNA concentration was higher in comparison with that of UCB (p = 0.0041) and that of the segment (p < 0.0001), as well as that of UCB in comparison with that of the segment (p < 0.0001). All samples were positive for GAPDH amplification and negative for MY09/MY11 and GP5/GP6+. Conclusions: Cryopreserved UCBUs were HPV-negative. Obtaining CFU DNA from clonogenic cultures with high concentrations and purity is feasible.


Assuntos
Humanos , Feminino , Adulto , Adulto Jovem , Papillomaviridae/isolamento & purificação , DNA Viral/isolamento & purificação , Células-Tronco Hematopoéticas/virologia , Genoma Viral , Sangue Fetal/virologia , Papillomaviridae/genética , Teste de Histocompatibilidade , Células HeLa , Criopreservação , Linhagem Celular , Reação em Cadeia da Polimerase/métodos , Gliceraldeído-3-Fosfato Desidrogenase (Fosforiladora) , Eletroforese em Gel de Ágar , Sangue Fetal/citologia
18.
Rev. gaúch. enferm ; 42: e20200241, 2021. tab, graf
Artigo em Inglês | LILACS, BDENF | ID: biblio-1251774

RESUMO

ABSTRACT Objective Measure umbilical cord pulsatility time and evaluate correlation/association with maternal and neonatal characteristics. Method Cross-sectional study, with 76 binomials, carried out in 2017, in a maternity hospital in Alagoas. Analysis with Pearson or Spearman correlation test and Mann-Whitney or Kruskal-Wallis test. Results Sixty-two parturients and their newborns participated of the research. The women had a gestational age ≥ 37 weeks, natural cephalic birth, without distortions. The newborns had average weight of 3326.29g, mostly male. The umbilical cord pulsatility time was 285.48s. There is a correlation between umbilical cord pulsatility time and placental delivery time (p<0.001). Other correlations/associations were not significant. Conclusion It suggested using a correlation between pulsatility time and placental delivery time in clinical decision making for good practices in childbirth assistance.


RESUMEN Objetivo Medir tiempo de pulsatilidad del cordón umbilical y evaluar la correlación/asociación con las características maternas y neonatales. Método Estudio transversal, con 76 pares, realizado en 2017, en maternidad en Alagoas. Análisis con la prueba de correlación de Pearson o Spearman y la prueba de Mann-Whitney o Kruskal-Wallis. Resultados Sesenta y dos mujeres en trabajo de parto y sus recién nacidos participaron. Las mujeres tenían edad gestacional ≥ 37 semanas, parto cefálico normal, sin distorsiones. Los recién nacidos tenían peso promedio de 3326.29g, la mayoría de ellos varones. Tiempo de pulsatilidad del cordón umbilical fue de 285.48s. Había correlación entre el tiempo de pulsatilidad del cordón umbilical y el momento del parto placentario (p<0,001). Otras correlaciones/asociaciones no fueron significativas. Conclusión Sugiere una correlación entre el tiempo de pulsatilidad y el tiempo de parto placentario para las buenas prácticas en la atención del parto.


RESUMO Objetivo Mensurar tempo de pulsatilidade do cordão umbilical e avaliar correlação/associação com característica maternas e neonatais. Método Estudo transversal, com 76 binômios, realizado no ano de 2017, em maternidade de Alagoas. Análise com teste de correlação de Pearson ou Spearman e teste de Mann-Whitney ou Kruskal-Wallis. Resultados Sessenta e duas parturientes e seus recém-nascidos participaram da pesquisa. As mulheres tinham idade gestacional ≥ 37 semanas, parto normal cefálico, sem distorcias. Os recém-nascidos tinham peso médio de 3326,29g, maioria do sexo masculino. O tempo de pulsatilidade do cordão umbilical foi 285,48s. Há correlação entre tempo de pulsatilidade do cordão umbilical e tempo de dequitação da placenta (p<0,001). Demais correlações/associações não foram significativas. Conclusão Sugere-se o uso correlação entre tempo de pulsatilidade e tempo de dequitação da placenta na tomada de decisão clínica para boas práticas na assistência ao parto.


Assuntos
Humanos , Feminino , Gravidez , Placenta/fisiologia , Cordão Umbilical/embriologia , Parto Normal , Enfermagem Obstétrica , Brasil , Epidemiologia Descritiva , Estudos Transversais , Maternidades
19.
J. Bras. Patol. Med. Lab. (Online) ; 57: e2332021, 2021. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1154605

RESUMO

ABSTRACT The umbilical cord constriction (UCC) is an uncommon condition and an important etiology for stillborn fetuses. The main goal of this study was to verify the UCC occurrence as the cause of intrauterine fetal death, the associated etiology and its pathological characteristics. Therefore, a descriptive retrospective cross-sectional study was developed using the database from a Pathology Institute, in Brazil, from 1995 to 2017. The results presented a total of 1,359 embryo/fetus deaths - 69 (5.07%) due to UCC, 60.9% males and 39.1% females. The average age of pregnant women was 27.5 years ± 7.2 years of standard deviation (SD). The majority of deaths occurred during the second trimester (76.5%), followed by the first (14.7%) and third (8.8%) trimesters, respectively. One constriction alone was found in 87% of cases, 11% had two constrictions and only 1% had three or more. The presence of congenital malformations was detected in 20.2% of necropsies, the identification of chronic fetal distress was described in 71% of the technical reports and 17% of the cases had obstructive vasculopathy characteristics in microscopy analysis. Regarding the anatomopathological characteristics between the male and female sexes, no significant difference was found (p > 0.05) correlating gestational age, weight or congenital malformations. UCC was a cause of fetal death found in 5% of the cases, and it was linked to congenital malformations, fetal distress and obliterative vasculopathy.


RESUMEN La constricción del cordón umbilical (CCU) es una condición infrecuente que no está bien descrita en la literatura, a pesar de ser una importante etiología observada en mortinatos. El objetivo de este estudio fue verificar la ocurrencia de CCU como causa de muerte fetal y las características patológicas asociadas. Para ello, se llevó a cabo un estudio retrospectivo transversal con informaciones de la base de datos de un Instituto de Patología, en Brasil, de 1995 hasta 2017. Los resultados fueron: 1.359 muertes de embriones/fetos, de las cuales 69 (5,07%) se debieron a CCU; 60,9% eran del sexo masculino y 39,1%, del femenino. El promedio de edad de las mujeres embarazadas fue de 27,5 anos; desviación estándar de ± 7,2 anos. La mayoría de las muertes ocurrió en el segundo trimestre (76,5%), seguido del primero (14,7%) y del tercero (8,8%). Entre el total de casos de CCU observados, 87% tuvieron sólo una constricción; 11%, dos; y 1%, tres o más. La presencia de malformaciones congénitas fue encontrada en 20,2% de las necropsias; la identificación de sufrimiento fetal crónico fue reportada en 71% de los informes; y características de vasculopatía obstructiva en el análisis de microscopía, en 17% de los casos. Con respecto a las características anatomopatológicas entre los sexos masculino y femenino, no se encontró ninguna diferencia significativa (p > 0,05) correlacionando edad gestacional de los fetos/embriones, peso o malformaciones congénitas. La CCU es una condición rara de muerte fetal asociada a bajo peso fetal y restricción de crecimiento. Nuestra investigación sugiere una posible relación entre la CCU y la vasculopatía obliterativa.


RESUMO A constrição de cordão umbilical (CCU) é uma condição infrequente, não bem descrita na literatura, apesar de ser uma importante etiologia observada em fetos natimortos. O objetivo deste estudo foi verificar a ocorrência de CCU como causa de morte fetal e as características etiopatológicas associadas. Para tanto, um estudo retrospectivo transversal foi realizado a partir das informações do banco de dados do Instituto de Patologia de Passo Fundo, durante os anos de 1995 a 2017. Os resultados foram: 1.359 mortes de embriões/fetos, das quais 69 (5,07%) foram devidas a CCU; 60,9% eram do sexo masculino e 39,1%, do feminino. A média de idade das gestantes foi de 27,5 anos; desvio padrão (DP) de ± 7,2 anos. A maioria das mortes ocorreu no segundo trimestre (76,5%), seguido pelo primeiro (14,7%) e terceiro (8,8%). Entre o total de CCU observadas, 87% tiveram ocorrência de apenas uma constrição; 11%, de duas; e 1%, de três ou mais. A presença de malformações congênitas foi encontrada em 20,2% das necropsias; a identificação de sofrimento fetal crônico foi relatada em 71% dos laudos; e características de vasculopatia obstrutiva na análise da microscopia, em 17% dos casos. Em relação às características anatomopatológicas entre os sexos masculino e feminino, nenhuma diferença significativa (p > 0,05) foi encontrada correlacionando idade gestacional dos fetos/embriões, peso ou malformações congênitas. A CCU é uma condição incomum de morte fetal associada a baixo peso fetal e restrição de crescimento. Nossa pesquisa sugere uma possível relação entre a CCU e a vasculopatia obliterativa.

20.
Rev. chil. pediatr ; 91(2): 226-231, abr. 2020. tab
Artigo em Espanhol | LILACS | ID: biblio-1098895

RESUMO

Resumen: Introducción: La sangre de cordón umbilical (SCU) como fuente para trasplante de células proge- nitoras hematopoyéticas (TPH) está bien establecida. Internacionalmente, menos del 10% de los TPH de SCU corresponde a donantes hermanos compatibles. Dentro de la red del Programa Infantil Nacional de Drogas Antineoplásicas (PINDA), existe desde enero 2004 un programa de donación dirigida de SCU para TPH. Pacientes y Método: Se diseñó un estudio observacional, retrospectivo, descriptivo, se revisaron el número y características de las unidades de SCU recolectadas en el PINDA y el número, características y evolución de los pacientes trasplantados con esas unidades entre enero de 2004 y octubre de 2018. Resultados: Sesenta unidades de SCU han sido recolectadas, de ellas 55 con registro completo. La mediana de volumen de las unidades almacenadas fue 74,8 ml (30,0-170,8), la mediana de células nucleadas totales 7,6 x 10e8 (2,0-21,1), mediana de células CD34+ 1,6 x 10e6 (0,2-11,6). Cuatro pacientes con leucemias de alto riesgo fueron trasplantados; mediana de segui miento es de 8 años. Todos desarrollaron complicaciones severas post TPH, uno de ellos falleció de recaída y los tres actualmente vivos presentan un Karnofsky/Lansky 100%. Conclusión: El programa ha permitido el trasplante de 4 pacientes que de otro modo no habrían tenido acceso a un donante. Este programa de donación dirigida puede ser considerado una primera etapa para el desarrollo de un banco público de sangre de cordón umbilical en Chile.


Abstract: Introduction: Cord blood (CB) as a source of Hematopoietic Stem Cells for Transplantation (HSCT) is well established. Worldwide, nonetheless, less than 10% of the CB HSCTs are performed with a match sibling donor. Since 2004, the Chilean National Childhood Cancer Program (PINDA) net work, has established a CB directed donation program for HSCT. Patients and Method: An obser vational, descriptive and retrospective study was designed to assess the number and characteristics of the CB units collected in the program as well as the number, clinical characteristics and follow-up of the patients who received an HSCT from those CB units between January 2004 and October 2018. Results: Sixty CB units have been collected; 55 of them with full records and stored. The median volume collected was 74.8 ml (30.0-170.8), the median number of total nucleated cells was 7.6 x 10e8 (2.0-21.1), and the median of CD34+ cells was 1.6 x 10e6 (0.2-11.6). Four high-risk leukemia patients received HSCT, all of them developed severe complications after transplantation and one patient died due to relapse. Those patients currently alive have a 100% Karnofsky/Lansky score. The median follow-up time was 8 years. Conclusion: The PINDA program has allowed 4 patients to be transplan ted who otherwise would not have had access to a donor. This directed donation program could be seen as a model for the development of a public cord blood bank in Chile.


Assuntos
Humanos , Masculino , Feminino , Recém-Nascido , Lactente , Pré-Escolar , Criança , Adolescente , Doadores de Sangue , Transplante de Células-Tronco Hematopoéticas/efeitos adversos , Transplante de Células-Tronco Hematopoéticas/métodos , Irmãos , Doação Dirigida de Tecido , Sangue Fetal , Chile , Saúde Pública , Estudos Retrospectivos , Seguimentos , Avaliação de Resultados em Cuidados de Saúde , Programas Nacionais de Saúde
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA