Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Rev. Col. Bras. Cir ; 49: e20223217, 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1422716

RESUMO

ABSTRACT Objectives: develop an easily accessible model for training the initial motor practice in microsurgery using corn kernels. Methods: ten corn kernels (Zea mays) were used. A 7mm longitudinal cut was made on one side of the corn grain. The training consisted of performing 4 simple knots between the edges of the incision, using 10-0 mononylon thread. The parameters analyzed were 1) cost of the model; 2) assembly time of the model test system; 3) time for performing the knots; 4) distance between the knots. Results: in all corn kernels tested, it was possible to perform the proposed microsurgical suture training, without any difficulty in the procedure. The average time to perform the 4 knots was 6.51±1.18 minutes. The total cost of the simulator model was R$3.59. The average distance between the knots was 1.7±0.3mm. The model developed from corn grains has an extremely low cost when compared to the use of animals or high-tech simulators. Other advantages are the easy availability of canned corn kernels and the possibility of making more than four knots along the 7mm incision. Conclusion: the training model developed has low cost, is easy to acquire and viable for training basic manual skills in microsurgery.


RESUMO Objetivo: desenvolver um modelo facilmente acessível para o treinamento da prática motora inicial em microcirurgia a partir da utilização de grãos de milho. Métodos: foram utilizados dez grãos de milho (Zea mays). Realizou-se um corte longitudinal de 7mm em uma das faces do grão de milho. O treinamento consistiu na realização de 4 pontos simples entre as bordas da incisão, utilizando fio de mononáilon 10-0. Os parâmetros analisados foram 1) custo do modelo; 2) tempo de montagem do sistema de teste do modelo; 3) tempo de realização dos nós; 4) distância entre os pontos. Resultados: em todos os grãos testados foi possível realizar o treinamento de sutura microcirúrgica proposto, sem dificuldade ao procedimento. O tempo médio para a realização dos 4 pontos foi de 6,51±1,18 minutos. O custo total do modelo simulatório foi de R$3,59. A distância média entre os pontos foi de 1,7±0,3mm. O modelo desenvolvido a partir de grãos de milhos apresenta custo extremamente baixo quando comparado ao uso de animais ou de simuladores de alta tecnologia. Outras vantagens são fácil disponibilidade de grãos de milho em conserva e possibilidade de serem realizados mais de quatro pontos ao longo da incisão de 7mm. Conclusão: o modelo de treinamento desenvolvido é de baixo custo, de fácil aquisição e viável para o treinamento de habilidades manuais básicas em microcirurgia.

2.
J. health inform ; 9(1): 3-10, jan.-mar. 2017. ilus, tab
Artigo em Português | LILACS | ID: biblio-832611

RESUMO

Objetivo: Avaliar a qualidade de Projeto Orientado a Objeto (POO) do Modelo de Objetos da openEHR, utilizando métricas de orientação a objeto (OO). Método: Um estudo experimental foi conduzido com artefatos da implementação em Java do openEHR e com métricas OO do modelo de qualidade QMOOD. Resultados: Identificou-se que os atributos de qualidade Reusabilidade e Funcionalidade, satisfizeram as expectativas do modelo de qualidade. Já os atributos Extensabilidade e Flexibilidade, mostraram-se instáveis, enquanto Facilidade de Compreensão ficou em queda. Complementarmente, foram identificados seis problemas de POO em estratégias de detecção de problemas de POO. Conclusão: O Modelo de Objetos da openEHR tem ganho de novos recursos e tem a capacidade de reutilizar módulos já existentes para resolver um novo problema. Entretanto, novos requisitos em recursos já existentes podem ser mais trabalhosos, assim como a adaptação do projeto para novos recursos. Também apresenta dificuldade de ser aprendido e compreendido devido ao aumento da complexidade.


Objective: To evaluate the quality of Object Oriented Design (OOD) of the openEHR Object Model, using Object Oriented (OO) metrics. Methods: An experimental study was designed and conducted using the openEHR Java reference implementation artifacts and with OO metrics of QMOOD quality model. Results: The results identified that the quality attributes of Reusability and Functionality satisfied the expectations of the quality model. The quality attributes of Flexibility and Extensibility proved unstable, while the quality attribute Understandability decreased. In addition, were identified six problems of OOD in detection strategies of problems of OOD. Conclusion: The openEHR Object Model gained new features and can reuse existing modules to solve a new problem. However, new requirements on existing resources can be difficult, as well as the adaptation of the project to new features. It also present difficulties to be learned and understood because of increase in the complexity.


Objetivo: Evaluar la calidad de Proyecto Orientado a Objeto (POO) del Modelo de Objetos del openEHR, utilizando métricas de orientación del objetos (OO). Método: Un estúdio experimental fue se llevó a cabo con artefactos de la implementación en Java del openEHR y con métricas OO del modelo de calidad QMOOD. Resultados: Ha identificado que los atributos de calidad Reusabilidad e Funcionalidad, han satisfecho las expectativas del modelo de calidad. Sin embargo los atributos Extensabilidad y Flexibilidad, han resultado ser inestables, mientras Facilidad de Comprensión ha establecido en baja. Además, se ha identificado seis problemas de POO en estrategias de detección de problemas de POO. Conclusión: El Modelo de Objetos del openEHR ha adquirido nuevas características y tiene la capacidad de reutilizar los módulos existentes para resolver un nuevo problema. Sin embargo, los nuevos requisitos sobre los recursos existentes puede ser engorroso, así como la adaptación del diseño para nuevos recursos. También presentan dificultades para aprender y comprender debido a la mayor complejidad.


Assuntos
Design de Software , Software , Avaliação de Programas e Projetos de Saúde , Desenvolvimento Experimental , Registros Eletrônicos de Saúde , Pesquisa Empírica , Pesquisa Qualitativa
3.
Rev. Col. Bras. Cir ; 39(3): 207-210, maio-jun. 2012. ilus, tab
Artigo em Português | LILACS | ID: lil-643149

RESUMO

OBJETIVO: desenvolver um modelo experimental de isquemia global normotérmica transitória capaz de demonstrar os tempos de isquemia e reperfusão necessários para desenvolvimento de lesão de isquemia/reperfusão em intestinos delgados de ratos Wistar através clampeamento de aorta abdominal suprarrenal. MÉTODOS: Vinte ratos Wistar adultos machos, pesando entre 250 e 350g, foram distribuídos aleatoriamente em cinco grupos, com quatro ratos cada, e submetidos a tempos crescentes de isquemia (0 - 30 - 45 - 60 - 90 minutos). Dentro de cada grupo, à exceção do grupo controle, dois ratos foram submetidos à 60 minutos de reperfusão e dois à 90 minutos. Após os procedimentos, procedeu-se análise histológica através de medição de áreas de necrose. RESULTADOS: O grau de necrose intestinal variou de 15 a 54% (p=0,0004). Houve tendência de aumento progressivo no grau de lesão relacionado ao aumento no tempo de isquemia, contudo, os maiores graus de lesão foram observados nos menores tempos de reperfusão. A análise do coeficiente de variação de necrose entre os dez grupos de isquemia/reperfusão demonstrou diferença estatisticamente significante em 15 postos, sendo 13 relacionados ao grupo controle. CONCLUSÃO: O modelo foi capaz de demonstrar os tempos necessários para que ocorra lesão de isquemia/reperfusão intestinal através de clampeamento aórtico e poderá servir como base para facilitar o desenvolvimento de estudos voltados para a compreensão deste tipo de lesão.


OBJECTIVE: To develop an experimental model of global normothermic ischemia able to demonstrate the transient ischemia and reperfusion periods required for development of ischemia/reperfusion injury in the small intestines of Wistar rats by clamping the abdominal aorta. METHODS: Twenty adult male Wistar rats weighing 250-350g were randomly divided into five groups with four rats each and submitted to increasing times of ischemia (0 - 30 - 45 - 60 - 90 minutes). Within each group, except the control one, two rats underwent 60 minutes of reperfusion and two 90 minutes. After the procedures, histological analysis was conducted by measurement of areas of necrosis. RESULTS: The degree of intestinal necrosis ranged from 15% to 54% (p = 0.0004). There was progressive increase in the degree of injury related to increase in ischemic time. However, greater degrees of injury were observed in the lowest times of reperfusion. The analysis of the coefficient of variation of necrosis among the ten groups of ischemia/reperfusion showed a statistically significant difference in 15 areas, 13 related to the control group. CONCLUSION: The model was able to show the periods required for the occurrence of ischemia/reperfusion injury by aortic clamping and can serve as a basis to facilitate the development of studies that aim at understanding this kind of injury.


Assuntos
Animais , Masculino , Ratos , Modelos Animais de Doenças , Isquemia , Mesentério/irrigação sanguínea , Aorta Abdominal , Constrição , Ratos Wistar , Reperfusão/métodos
4.
Acta cir. bras ; 27(5): 306-310, May 2012. ilus, graf
Artigo em Inglês | LILACS | ID: lil-626244

RESUMO

PURPOSE: To describe technical aspects of a new experimental model that simulates a non heart beating organ donor. METHODS: Landrace pigs were operated on and cardiac arrest was obtained by means of myocardial infarction and interruption of ventilator support. RESULTS: Mean cardiac frequency, systolic and diastolic blood pressure levels, central venous pressure, oxygen saturation and concentration of expired CO2 dropout occurred at seven minutes after cardiac arrest. CONCLUSION: The procedure was easily reproduced and a homogeneous circulatory failure could de obtained by the end of seven minutes. The model is suitable for further studies regarding abdominal organ transplantation.


OBJETIVO: Descrever os aspectos técnicos de um novo modelo experimental que simula um doador de órgãos após a parada cardíaca. MÉTODOS: Suínos da raça Landrace foram operados e a parada cardíaca foi obtida por meio de infarto do miocárdio e interrupção do suporte ventilatório. RESULTADOS: Freqüência cardíaca, pressão arterial sistólica e diastólica, pressão venosa central, saturação de oxigênio e concentração parcial de CO2 são consistentes com falência hemodinâmica ao final de sete minutos. CONCLUSÕES: O procedimento foi facilmente executado e uma falência circulatória pode ser obtida ao final de sete minutos. Este modelo é adequado para estudos posteriores com respeito a preservação e tranplantes de órgãos abdominais.


Assuntos
Animais , Masculino , Parada Cardíaca , Modelos Animais , Preservação de Órgãos , Doadores de Tecidos , Dióxido de Carbono/metabolismo , Sobrevivência de Enxerto , Parada Cardíaca/fisiopatologia , Oxigênio/metabolismo , Suínos , Transplante/métodos
5.
Rev. bras. enferm ; 62(2): 200-203, mar.-abr. 2009.
Artigo em Português | LILACS, BDENF | ID: lil-512350

RESUMO

Estudo quase-experimental, com o qual objetivou aperfeiçoar o sistema de projeção dos pontos luminosos de um método já existente, tornando-o portátil, e verificar a acurácia desse novo sistema. O estudo foi realizado por meio do desenvolvimento de um sistema de fotografia digitalizada e processada pela visão computacional em um modelo de superfície plana. Os resultados mostraram erro de 1,51 por cento para a profundidade e de -10,42 por cento para o volume, concluindo ser um método adequado para aferição de profundidade e volume com erros de acurácia compatíveis com os descritos na literatura.


That is an quasi-experimental study that aims to improve and make portable an existing method for projecting light points to estimate geometrical properties of a cavity. A computer vision system was developed in order to process input images and calculate volume and depth of a cavity in a plain surface. An error of 1,51 percent for depth and -10,42 percent for volume occurred. So this is an adequate method for estimating geometrical properties of cavities with accuracy errors compatible with those errors described in the literature.


Estudio casi-Aferição não-invasiva de úlcera por pressão simulada em modelo planoexperimental, con el objetivo de perfeccionar el sistema de proyección de los puntos luminosos de un método ya existente, volviéndolo portátil, y verificar la acuracia de ese nuevo sistema. El estúdio realizado a través del desarrollo de um sistema de fotografia digitalizada y procesada por la visión computacional en un modelo de superfície llana. Los resultados mostraron um error de 1,51 por ciento para la profundidad y de -10,42 por ciento para el volumen, concluyendo ser método adecuado para la evaluación de los descriptos em la literatura.


Assuntos
Humanos , Úlcera por Pressão/patologia , Modelos Anatômicos
6.
Acta cir. bras ; 22(6): 499-502, Nov.-Dec. 2007. ilus
Artigo em Inglês | LILACS | ID: lil-472583

RESUMO

PURPOSE: To provide information gathered upon the execution of trials assessing tensile strength in experimental surgeries. METHODS: Descriptive study considering details on the execution of trials assessing tensile strength in experimental surgery. RESULTS: The analysis of the rupture force in a mechanical test machine is an adequate technique since it provides precise and quick results. It can, undoubtedly, be developed in this context of the eminently mechanical analysis of trials on experimental surgery. CONCLUSION: The utilization of a mechanical test machine is a useful tool in the assessment of materials' strength, providing accurate results. Nevertheless the trials must be well structured analyzing the multiple variables so as to attain a pattern of constant reproducibility and to provide the necessary reliability.


OBJETIVO: Fornecer informações advindas da experiência com a realização de trabalhos que avaliam a resistência tênsil em cirurgia experimental. MÉTODOS: Estudo descritivo considerando detalhes da execução de trabalhos que avaliam a resistência tênsil em cirurgia experimental. RESULTADOS: A análise da força de ruptura em máquina de ensaios mecânicos é uma técnica apropriada e que fornece resultados precisos e rápidos. Pode ser desenvolvida neste contexto da análise eminentemente mecânica de estudos em cirurgia experimental. CONCLUSÃO: A utilização da máquina de ensaios mecânicos é uma ferramenta útil na avaliação da resistência de materiais fornecendo resultados precisos. Entretanto os trabalhos devem ser estruturados analisando múltiplas variáveis para alcançar um padrão de reprodutibilidade constante e trazer a confiabilidade necessária ao estudo.


Assuntos
Animais , Teste de Materiais/instrumentação , Resistência à Tração , Experimentação Animal , Teste de Materiais/métodos , Maleabilidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA