Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Rev. venez. cir ; 70(1): 12-25, 2017. ilus, tab
Artigo em Espanhol | LILACS, LIVECS | ID: biblio-1372498

RESUMO

El presente artículo, analiza los diferentes aspectos relacionadoscon las medidas de prevención, aplicables a la preparación delpaciente y al ambiente quirúrgico, con la finalidad de disminuir laincidencia de infecciones operatorias. Se describen todos los facto-res ambientales y funcionales, que nos ayudarán a blindar las áreasquirúrgicas y las centrales de esterilización, para ofrecer una atención quirúrgica de calidad, siguiendo las normas y procedimientosrecomendados por organismos internacionales como la OMS(AU)


This article analyses the different aspects related to preventionmeasures, applicable to patient preparedness and surgical environ-ment, in order to reduce the incidence of operating infections. Allenvironmental and functional factors are described, which will helpus to shield surgical areas and sterilization plants, to offer qualitysurgical care, following standards and procedures recommendedby international organizations such as WHO(AU)


Assuntos
Salas Cirúrgicas , Infecções , Cuidados Intraoperatórios , Pacientes , Infecção Hospitalar
2.
Rev. Esc. Enferm. USP ; Rev. Esc. Enferm. USP;37(1): 90-96, mar. 2003. ilus
Artigo em Português | LILACS, BDENF | ID: lil-500332

RESUMO

A atividade antimicrobiana das Pastilhas de Paraformaldeído, reproduzindo as condições de uso das Instituições de Saúde do Brasil (sem o aquecimento, sem o acréscimo da umidade relativa, a 5 por cento, por um período longo de exposição de 12 horas), foi avaliada "in vitro" por meio do monitoramento microbiológico, segundo a metodologia da AOAC, adotada oficialmente pelo Ministério da Saúde do Brasil para o registro dessa categoria de produtos. Os resultados dos experimentos refutaram a ação esterilizante das Pastilhas de Paraformaldeído nestas condições. Diante destes resultados, realizou-se, então, os testes para avaliação desinfetante do produto utilizando-se o Método de Diluição de Uso, preconizada pela AOAC, adaptado para produtos gasosos, contra os microrganismos teste padronizados Staphylococcus aureus (ATCC nº. 6538), Samonella choleraesuis (ATCC nº. 10708) e Pseudomonas aeruginosa (ATCC nº. 15442). Nestes experimentos, os resultados das culturas mostraram-se 100 por cento negativos contra todas as bactérias testadas inferindo-se indícios de atividade desinfetante de alto nível.


The sterilizing activity of Parafolmaldehyde Tablets reproducing the conditions of use in the Brazilian health Institutions (without the heating, without increment of the relative humidity, in 0.5 percent, even for a long period of exhibition of 12 hours) was evaluated "in vitro" by microbiologic monitoring, according to the methodology of the AOAC, officially adopted by the Brazilian Health Ministry for registration of that category of products. The results of the experiments refuted the sterilizing action of Parafolmaldehyde Tablets in this conditions. Thus, it was evaluated the disinfectant action of the product using the vegetative bacterias by Use Dilution Method, preconized for AOAC and adapted for gaseous products, against the tests microorganisms standardized Staphylococcus aureus (ATCC n. 6538), Samonella choleraesuis (ATCC n. 10708) and Pseudomonas aeruginosa (ATCC n. 15442). In these experiments, the results of the cultures showed 100 percent negative against all the tested bacterias inferring indications of disinfectant activity of high level action.


La actividad antimicrobiana de las Pastillas de Paraformaldehído, reproduciendo las condiciones de uso en las Instituciones de Salud del Brasil (sin el calentamiento y aumento de la humedad relativa, en un porcentaje del 0,5 por ciento, pese al largo período de exposición de 12 horas), fue evaluada "in vitro" por medio del monitoramiento microbiológico, según la metodología de la AOAC, adoptada oficialmente por el Ministerio de Salud del Brasil para el registro de esa categoría de produtos. Los resultados de los experimentos refutaron la acción esterilizante de las Pastillas de Paraformaldehído en las condiciones estudiadas. Frente a estos resultados se realizó, entonces, los test para evaluación desinfectante del produto utilizándose el Método de Dilución de Uso, preconizada por la AOAC, adaptado para productos gaseosos, contra los microorganismos test patronizados Staphylococcus aureus (ATCC nº. 6538), Samonella choleraesuis (ATCC nº. 10708) e Pseudomonas aeruginosa (ATCC nº. 15442). En estos experimentos, los resultados de los cultivos se mostraron 100 por ciento negativos contra todas las bacterias probadas. Los resultados microbiológicos nos permiten inferir que las Pastillas de Paraformaldehído mostró indícios de actividad desinfectante de alto nivel.


Assuntos
Anti-Infecciosos Locais , Formaldeído , Polímeros , Esterilização/métodos , Bacillus subtilis/efeitos dos fármacos , Brasil , Clostridium/efeitos dos fármacos , Comprimidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA