RESUMO
ABSTRACT Objective: to evaluate esophageal dysmotility (ED) and the extent of Barrett's esophagus (BE) before and after laparoscopic Nissen fundoplication (LNF) in patients previously diagnosed with BE and ED. Methods: twenty-two patients with BE diagnosed by upper gastrointestinal (GI) endoscopy with biopsies and ED diagnosed by conventional esophageal manometry (CEM) were submitted to a LNF, and followed up with clinical evaluations, upper GI endoscopy with biopsies and CEM, for a minimum of 12 months after the surgical procedure. Results : sixteen patients were male (72.7%) and six were females (27.3%). The mean age was 55.14 (± 15.52) years old. and the mean postoperative follow-up was 26.2 months. The upper GI endoscopy showed that the mean length of BE was 4.09 cm preoperatively and 3.91cm postoperatively (p=0.042). The evaluation of esophageal dysmotility through conventional manometry showed that: the preoperative median of the lower esophageal sphincter resting pressure (LESRP) was 9.15 mmHg and 13.2 mmHg postoperatively (p=0.006). The preoperative median of the esophageal contraction amplitude was 47.85 mmHg, and 57.50 mmHg postoperatively (p=0.408). Preoperative evaluation of esophageal peristalsis showed that 13.6% of the sample presented diffuse esophageal spasm and 9.1% ineffective esophageal motility. In the postoperative, 4.5% of patients had diffuse esophageal spasm, 13.6% of aperistalsis and 22.7% of ineffective motor activity (p=0.133). Conclusion: LNF decreased the BE extension, increased the LES resting pressure, and increased the amplitude of the distal esophageal contraction; however, it was unable to improve ED.
RESUMO Objetivo: avaliar a dismotilidade esofágica (DE) e a extensão do esôfago de Barrett (EB) antes e depois da fundoplicatura laparoscópica a Nissen (FLN) em pacientes previamente diagnosticados com EB e DE. Método: vinte e dois pacientes com EB diagnosticada por endoscopia digestiva alta (EDA) com biópsias e DE diagnosticada por manometria esofágica convencional (MEC) foram submetidos a FLN, e acompanhados por avaliações clínicas, endoscopia digestiva alta com biópsias e MEC, por no mínimo 12 meses após o procedimento cirúrgico. Resultados: dezesseis pacientes eram do sexo masculino (72,7%) e seis do feminino (27,3%). A média de idade foi de 55,14 (± 15,52) anos e o seguimento pós-operatório médio foi de 26,2 meses. A endoscopia digestiva alta mostrou que o comprimento médio do EB foi de 4,09 cm no pré-operatório e 3,91 cm no pós-operatório (p = 0,042). A avaliação da dismotilidade esofágica por meio da manometria convencional mostrou que a mediana pré-operatória da pressão de repouso do esfíncter esofágico inferior (PREEI) foi de 9,15 mmHg, e de 13,2 mmHg no pós-operatório (p = 0,006). A mediana pré-operatória da amplitude de contração esofágica foi de 47,85 mmHg, e de 57,50 mmHg no pós-operatório (p = 0,408). A avaliação pré-operatória do peristaltismo esofágico mostrou que 13,6% da amostra apresentava espasmo esofágico difuso e 9,1%, motilidade esofágica ineficaz. No pós-operatório, 4,5% dos pacientes apresentaram espasmo esofágico difuso, 13,6% de aperistalse e 22,7% de atividade motora ineficaz (p = 0,133). Conclusões: a FLN diminuiu a extensão do EB, aumentou a pressão de repouso do EEI e aumentou a amplitude da contração esofágica distal; no entanto, não foi capaz de melhorar a DE.
Assuntos
Humanos , Masculino , Feminino , Adulto , Idoso , Esôfago de Barrett/cirurgia , Transtornos da Motilidade Esofágica/cirurgia , Laparoscopia , Fundoplicatura/efeitos adversos , Espasmo Esofágico Difuso , Resultado do Tratamento , Fundoplicatura/métodos , Pessoa de Meia-IdadeRESUMO
ABSTRACT Background: High-resolution manometry is more costly but clinically superior to conventional manometry. Water-perfused systems may decrease costs, but it is unclear if they are as reliable as solid-state systems, and reference values are interchangeable. Aim: To validate normal values for a new water-perfusion high-resolution manometry system. Methods: Normative values for a 24-sensors water perfused high-resolution manometry system were validated by studying 225 individuals who underwent high resolution manometry for clinical complaints. Patients were divided in four groups: group 1 - gastroesophageal reflux disease; group 2 - achalasia; group 3 - systemic diseases with possible esophageal manifestation; and group 4 - dysphagia. Results: In group 1, a hypotonic lower esophageal sphincter was found in 49% of individuals with positive 24 h pH monitoring, and in 28% in pH-negative individuals. In groups 2 and 3, aperistalsis was found in all individuals. In group 4, only one patient (14%) had normal high-resolution manometry. Conclusions: The normal values determined for this low-cost water-perfused HRM system with unique peristaltic pump and helicoidal sensor distribution are discriminatory of most abnormalities of esophageal motility seen in clinical practice.
RESUMO Racional: A manometria de alta resolução é mais custosa, porém clinicamente superior à manometria convencional. Sistemas por perfusão de água podem ter custo diminuído, mas não é certo se são tão eficazes quanto aos sistemas de estado sólido e se os valores de referência são intercambiáveis. Objetivo: Este estudo visa validar valores de normalidade para um novo sistema por perfusão de água. Método: Valores de normalidade para um sistema de manometria de alta resolução de 24 sensores por perfusão de água foram validados estudando 225 indivíduos submetidos à manometria de alta resolução por queixas clínicas. Pacientes foram divididos em quatro grupos: grupo 1 - doença do refluxo gastroesofágico; grupo 2 - acalasia; grupo 3 - doenças sistêmicas com possível doenças sistêmicas com comprometimento esofágico; e grupo 4 - pacientes com disfagia. Resultado: No grupo 1, esfíncter esofagiano inferior hipotônico foi encontrado em 49% dos indivíduos com pHmetria positiva e 28% daqueles com pHmetria negativa. Nos grupos 2 e 3, aperistalse foi encontrada em todos indivíduos. No grupo 4, somente um paciente (14%) tinha manometria normal. Conclusão: Os valores de normalidade definidos para este sistema de manometria de alta resolução por perfusão de água são discriminatórios da maioria das anormalidades da motilidade esofágica vistas na prática clínica.